Question about Haier HBF05EBSS Commercial Beverage Dispenser

1 Answer

I have a kegerator. It's not functioning. When plugged in no clicking no sound nothing. Wondering if it's the overload switch or relay.

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Haier Master
  • 1,070 Answers

Http://www.haieramerica.com/en/asset/product/1ffd77cfa0
This site has your product manual for your dispenser but it is very vague on trouble shooting the cooling system.
In general, the compressor is controlled by a thermostat that is usually located in the conditioned space. It cycles the compressor on and off based on the sensed temperature and the setting that it is adjusted to.
So, let's talk in general refrigeration terms. Where the compressor is located, is there a fan? If so, is it running? That fan is usually the condenser fan and is wired to come on anytime the compressor is supposed to be running. If the fan is running and the compressor is not, then there is an issue with the compressor. If the fan is not running and the compressor is not running, then there is an issue with either power or the thermostat. If the compressor is running and the fan is not, then there is an issue with the fan.
This is a good starting point. Let me know if I can be of further help.

Posted on Mar 24, 2011

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Not starting


ck that you are getting power to it some of them have fuses on them , the switch may be bad

Mar 28, 2014 | Haier Kegerator HBF05EBSS Draft Beer Tap...

1 Answer

TDD 2 Kegerator clicking and not cooling?


It's extremely rare that the compressor will be any good. Usually replacing the start relay does nothing on these small units. If you know how to use a multi-meter and are any good at wiring the cheapest way to go is to get what is called a 3-in-1 start kit at a HVAC wholesaler. You need to know the model of the compressor and/or the horsepower to get the right one. I would recommend getting a service tech to look it over though. Most likely the compressor is locked up.

Nov 16, 2012 | True Direct Draw Systems: Kegerator TDD-2

2 Answers

My ryobi bst10 table saw stopped working. The switch appears fine. I am wondering if the overload protector could be a problem. The little button seems loose?


I'm having the same problem only mine is bran new and has only been turned in one time when I put it together it worked then now the switch is lose and does not make a clicking sound what is wrong with mine

Aug 22, 2012 | Ryobi Saws

1 Answer

Whirlpool model GC3SHEXNS - was in a flood in my house appx. 20" - light comes on in fridge but nothing else happens when I plug it in - just wondering if it's worth having serviced?


:
Hi!
A relay starts the compressor with a higher voltage and then quickly kicks out
It does a lot of clicking (trying to start over and over again)
If thats what is happening with yours
Its best for a tech to replace The relay but you can do it
Take your model number to your Local Appliance parts store they will have a diagram
showing you how to install the relay. Its called a hard start relay
I use part no ERP410 POWER START RELAY, CAPACITOR AND OVERLOAD all in one. (110 v)

If you still have trouble Go Here:

http://www.applianceaid.com/procedures.html

Thank you for using fixya
Leo Ponder
PLEASE VOTE FOR ME IF THIS WAS HELPFUL

Sep 14, 2011 | Whirlpool Refrigerators

1 Answer

I have a 2 year old Haier kegerator and it seems to have stopped working. I hear a clicking sound which I believe is the compressor going on and off. I have done some research and found that this is a...


Do you have any technical background? There is a simple and sure fix to this but you will need to be able to read a wiring diagram and have basic electrical tools like a wire stripper and electrical tape.

Dec 02, 2010 | Haier HBF05EBSS Commercial Beverage...

1 Answer

My kegerator recently stopped cooling. When I plug it in the fan starts up and then compressor starts for a second and there is a clicking noise and it turns off. I replaced the relay and start/run...


The overload relay is the likely problem. See if it is burnt looking or if it rattles when you shake it. Or just replace it. It's not expensive. If that's not the problem then it's the compressor.

Sep 22, 2010 | True TDD-2CT Beverage Cooler

1 Answer

I'm getting a wierd sound coming from my JBL2088HES refrigerator. It is a buzz like an electric shaver followed by a click. It seems to happen in 3 min intervals. Any Idea what it could be?


Kevin,

It sounds like it could be the compressor overload relay or the compressor itself. Lets hope that it is the overload relay, most compressor replacements are very expensive.

The overload/relay isn't very expensive and replacing it will be cheaper than calling a repair tech to tell you if it is the compressor or the overload/relay.

This is a relatively simple repair, if you look at your compressor you will find two wires connected to a small box ( overload/relay )
To remove the overload first you must remove the metal retainer by unhooking it with a pair of needle nose pliers.
Now remove the overload relay by pulling it away from the compressor.

The relay for your refrigerator has a capacitor connected to it, the capacitor and the relay are sold as one piece part # 67005560.

all that you have to do is remove the old relay with the capacitor from the wires by pulling the plug off and connecting the new overload/relay/capacitor to it, reinstall the relay to the compressor and you are done.

Good Luck
Check us out at www.centuryappliancerepair.com

Dec 10, 2009 | Jenn-Air Refrigerators

1 Answer

My bev air bm23 kegerator wont cool. the fan works like it is suppose to inside 24/7. The fan outside works as well. There is a hhhmmm sound and then a click. It thought it was the compressor so i took the...


Yes replacing the relay may fix the problem. You want to replace all the start parts. Overload, relay, and capacitor if one is present. Your unit is probably 1/3 horse power or less. You may be able to install a universal 3N1 starter from Supco, rated at 1/4 -1/3 H.P. If new start gear does not fix the problem you may need a new compressor.

Nov 05, 2009 | Beverage-Air BM23

2 Answers

I hear buzzing sound and a click like a switch when the compressure turns on.


Then you will need to get that fixed. Sounds to me that your start relay and start capacitor are not making good start connection and the overload is clicking out. If you don't fix this problem soon the compressor may be damaged. I need to know if your model is the MSD2756G or a different model. Let me know..Sea Breeze

Jun 21, 2009 | Maytag MSD2756G Side by Side Refrigerator

1 Answer

Burning smell and dead mini-fridge/kegerator


If the compressor is being used for extended times without resting or getting the product cooled, could be the problem. On small refrigerators the inside is sized for the work load. The condenser coil on back or in some cases under the outside skin of the refrigerator is designed to cool the area inside by releasing the heat from inside.. You may need to modify your cooler to handle such loads with more cooling capacity and condenser with fan to help bring the product temps down more efficiently. Let me know, Thanks, Sea Breeze

Mar 19, 2009 | Sanyo SR-4912M

Not finding what you are looking for?
Haier HBF05EBSS Commercial Beverage Dispenser Logo

415 people viewed this question

Ask a Question

Usually answered in minutes!

Top Haier Refrigerators Experts

John Tripp
John Tripp

Level 3 Expert

4654 Answers

doggzzz

Level 1 Expert

14 Answers

Brad Brown

Level 3 Expert

15557 Answers

Are you a Haier Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...