Question about Jandy AquaLink RS2/6 All Button Dual Equipment -

1 Answer

My jandy rs aqualink rs8ps circuit board fuse keeps blowing. is this a problem with the transformer?

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Top Expert:

    An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Jandy Master
  • 4,290 Answers

No with an aux mark all auxes wich goes where unplug all then replace fuse hook up one at a time to see which one blows fuse then check that relay and wiring maybe motor shorting out or lights got water or bad wire

Posted on Jan 30, 2016

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

CNC65
  • 15 Answers

SOURCE: Jandy Aqualink - Rs, button control red lites on contriol panel

HAVE YOU HAD ANY LIGHTNING STRIKES?

Posted on Nov 06, 2008

SOURCE: Jandy Aqualink RSO301 keeps blowing fuse

Great discovery! You're welcome.

Could you please take a few and rate my assistance.

thanks...

Charlie

Posted on May 27, 2009

SHANEOK
  • 21 Answers

SOURCE: Jandy Aqualink with IntelliFlo VS-3050

Jandy has an e pump.It would be cheaper to go that route.the Inteliflo is not compatible with the jandy system .If money is not a concern the pentair product is the way to go.

Posted on Oct 04, 2009

  • 246 Answers

SOURCE: I have a jandy aqualink RS PDA. It will not

open the antena box and follow the instruction to reset if not working the antena need to be replace

Posted on Oct 15, 2009

jyackle5
  • 8197 Answers

SOURCE: Can I get a manual for a Jandy aqualink rs?

You can get the manual for the item on the link below.

http://www.southshoregunitepools.com/resources/manuals/jandy_installation.pdf

If that is not the right one can I get the model # or you can go to the link below.

http://www.jandy.com/html/productsupport/#manuals


Good Luck and please rate 4 thumbs up for the free answer

Posted on Jun 20, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I get no power indications to my Aqualink. I checked the circuit breakers, Any idea what is going on?


check back of PCB board fuse might be blown if keeps blowing fuses unplug all auxs then plug in 1 at a time till it blows thats whats wrong or check powersupply should be 24 volts ac on back board

Sep 23, 2012 | Jandy AQUALINK RS TELELINK KIT

1 Answer

My jandy # 8265 will not turn on. I replace the battery and still dont work.


if voltage coming in check transformer if 24 volts at back of PC board need new control board if no voltage replace transformer or check fuse also

Jun 23, 2011 | Jandy AQUALINK RS TELELINK KIT

1 Answer

I have a Jandy Aqualink RS system. The wires for one of the valve activators was shorted and the outdoor control panel and the indoor control panel lost power. None of the circuit breakers was tripped.


On the RS system there is a small fuse on the back of the circuit board. That may have been burnt. It acts as a safety for the transformer. Make sure ALL of the power is off, then check that fuse. Do not keep the shorted valve actuator plugged in. Replace it, or leave it disconnected. Then replace the fuse. Then re-apply power to the unit. Otherwise your transformer may go out next. If the fuse is not burnt, which would surprise me, you may have a burnt transformer.

Apr 04, 2011 | Jandy AQUALINK RS TELELINK KIT

1 Answer

The fuse on my circuit board keeps blowing after a thunder storm. Need to replace the entire circuit board for my RS8 system. Any sugestions on where I can purchase just the circuit board? Mike


unplug all the aux plugs but mark them replace fuse turn on if it still blows need a new board if not plug in auxs 1 at a time till it pops then check out that aux for shorts sometimes the relays short out

Mar 17, 2011 | Jandy AquaLink RS OneTouch RS8 Pool or Spa...

1 Answer

Screen is blank ... changing to new batteries does not help?


see if voltage coming into transformer if ok check transformer for 24 volts ac at back plug of PCB board also check fuse on back of board

Jan 04, 2010 | Jandy AQUALINK RS TELELINK KIT

1 Answer

Power to the box but fuse keeps blowing.


Yes their are 2 fuses on a aqualink. most fuses are clear mome are white make sure the fuse was the same, becuase a white fuse will burn slower, take more heat.

Oct 03, 2009 | Jandy AQUALINK RS TELELINK KIT

2 Answers

My jandy pool control panel has gone dark as if it has no power. is there a fuse or something of that nature that i can check?


check the breaker that is marked rs in jandy service panel first.Then check the red terminal bar in the upper left corner of service panel. It may be unplugged or have loose or broken wires.then check the red terminal bar on the inside remote

Oct 01, 2009 | Jandy Aqualink - Rs24 One Touch Pool / Spa...

1 Answer

My aqualink power center and indoor control has no power, but the aquarite chlorine system is still lit up. Is there a fuse or a board the can be replaced?


The chlorine controller is wired seperately from the aqualink, you need to find a different circuit breaker/fuse to power it down or trace the cord and unplug them.

Sep 15, 2009 | Jandy AQUALINK RS TELELINK KIT

1 Answer

Jandy Aqualink RSO301 keeps blowing fuse


Great discovery! You're welcome.

Could you please take a few and rate my assistance.

thanks...

Charlie

May 26, 2009 | Jandy AQUALINK RS TELELINK KIT

1 Answer

No power at the power panel( Aqualink RS8)


if unit comes on write down all auxs then remove plugs replace fuse turn on then plug one in at a time till it blows then you know which auw then see if wires are burnt

Apr 25, 2009 | Jandy AQUALINK RS TELELINK KIT

Not finding what you are looking for?
Jandy AquaLink RS2/6 All Button Dual Equipment -  Logo

Related Topics:

175 people viewed this question

Ask a Question

Usually answered in minutes!

Top Jandy Pool & Spa Experts

David Spradling
David Spradling

Level 3 Expert

4290 Answers

Pj Kiley
Pj Kiley

Level 1 Expert

21 Answers

Bill Jordan

Level 2 Expert

372 Answers

Are you a Jandy Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...