Question about Dayton Permanent Split Capacitor Motor Fan

Open Question

Hi, Have a vintage air compressor with a Dayton electric motor From Daytom electric Mfg. Co., Chicago Illinois Model c792c1 frame 6665 Currently wired for 220, like to run on 110 Volts listed as 115/208-230 on the "tin tag" on the side of the motor. Tried on 110, motor turned slowly and surged, but did turn freely.

Posted by on

5 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 2976 Answers

SOURCE: how to connect the Dayton Capacitor Start Motor to 230 volts ?

In the **********, the screws will be market L1 & L2. There will also be a jumper that needs to be connected between the 2 terminals for 230V.

Posted on Aug 28, 2009

  • 1 Answer

SOURCE: Dayton Attic fan running backwards

If the fan blade is on properly, then you probably have the wiring reversed. If you connect a line from motor to red box wire, and other motor line to black box wire, it will turn clockwise. If you reverse the wiring it will turn counter-clockwise ;-)

Posted on Jun 01, 2010

  • 1 Answer

SOURCE: wiring diagram for dayton ac electric motor

i need wiring diagram for a dayton electric motor 4mb22

Posted on Oct 21, 2010

  • 1 Answer

SOURCE: I need a wiring diagram for a dayton 120/230 v

I have dayton motor 3/4 hp 120-240v it has 3 contacts 1-2& 4 it has 5 wires 2 white 2 red 1 blue. I want forward rotation! what do I do?

Posted on Jan 26, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Could sure use a wiring diagram for a Dayton 5k961c motor.


Electric Motors: dayton motor, Electric motor repair Kansas ...

en.allexperts.com > Industry > Machine Tools > Electric Motors
Aug 24, 2010 - Electric motor repair Kansas City MEAR Service 816-650-4030: Tyler, it is ... i have a dayton motor with no wiring diagram. i need a wiring diagram for a dayton motor with a model # 5k961c and a reference # r67745ck733 ... 1992 Dodge Dynasty Blower Motor Wiring Diagram · 1998 Ford Escort Blower ...

wiring diagram (ideally color) for Dayton belt drive motor Model ...

www.electro-tech-online.com > ... > General Electronics Chat

Apr 29, 2012 - 9 posts - ‎3 authors
There is a sticker on motor indicating wiring, but seems only an. ... This is a motor for vented - big blade ceiling fan -- a belt driven Dayton Motor ...

DAYTON 1/4 HP Condenser Fan Motor,Permanent Split ...

https://www.grainger.com/.../DAYTON-1-4-HP-Condens...

W. W. Grainger
Rating: 3.8 - ‎6 reviews
Shop DAYTON 1/4 HP Condenser Fan Motor,Permanent Split Capacitor,1075 Nameplate RPM,208-230 ... Typical HVAC Condenser Fan Motor Wiring Diagram ...

DAYTON 1/3 HP Direct Drive Blower Motor, Permanent Split ...

https://www.grainger.com/.../DAYTON-1-3-HP-Direct-D...

W. W. Grainger

Jan 23, 2016 | Dayton Dryers

1 Answer

Need fan motor for model 2E440


Try Grainger

dayton 2e440 heater Questions & Answers - Fixya

www.fixya.com > Forum > Tags
... a Dayton Model 2YU40 electric heater Need manual for Dayton. ... looking for a replacement fan and fan motor for a Dayton model 2E454B electric wall heater.

Dayton rheostat fan motor Heaters Questions & Answers ...

www.fixya.com > Forum > Tags > rheostat fan motor > Heaters
Dayton heaters rheostat fan motor related questions and answers. ... UP BUT FAN WONT KICK ON Could be one of several problems dependant on the model you have.... The motors are noisy in 2 Dayton 2e440 heaters. I ... I'm looking for a replacement fan and fan motor for a Dayton model 2E454B electric wall heater.

DAYTON Electric Wall Heater, Recessed or Surface ...

www.grainger.com/.../DAYTON-Electric-Wall-Heater-3...

W. W. GraingerShop DAYTON Electric Wall Heater, Recessed or Surface, Voltage 208/240, Watts ...Item # 3UG56; Mfr. Model # 3UG56; UNSPSC # 40101814; Catalog Page # 4277; Shipping Weight 20.65 lbs. ... Additional features include a built-in thermal cutout andfan delay switch for added safety ... Need Help Finding Repair Parts?

Jan 09, 2016 | Dayton Electric Heater

1 Answer

Sylvania electric stove heater, black (model SO111R-MBK) stopped working


Got a stove electric space heater But it will not trunk on just the flame button but no flames and no heat what can I do to fix this .boxes the remote control have to light up....Albert Gomez..2124 North Keeler ave..Chicago Illinois..60639...18722062470.....

Dec 08, 2012 | Sylvania Electric Stove Heater, Black...

1 Answer

Chicago pnematic 8gal air compressor will not start


Well it should be limited to a bad pressure switch, overload/overtemp switch(if it has one), or a bad motor. You can check for power with a multi-meter set on a/c volts and see if you have power to your motor. A more 'backyard' approach would be to jumper your power directly to the motor, bypassing the switches, but that could be dangerous especially if you left your switches bypassed because the compressor would never shut off and eventually hopefully blow your overpressure valve.

Mar 21, 2012 | Chicago Pneumatic Air Tools & Compressors

1 Answer

Dayton model 5k117u compressor motor turns the wrong direction


Hi,
Open up the electrical box on the side of the motor...if the wires are numbered switch the #5 and the #8 wire...
If the wires are color coded then switch the red and the black wires and the motor will run the other way...

heatman101

Jun 29, 2011 | Air Tools & Compressors

1 Answer

I got a dayton welding maching model 5756 i need a manual


icon1.gif I got the following from a post regarding Dayton Welding Machines 5756: I have a Dayton 6Z935C welder with manual. It's probably 10+ years old. The address on the back of the manual is

Dayton Electric Mfg. Co.
5959 W. Howard Street
Niles, IL 60714

Sorry, no phone number is supplied.

An attached list of US Authorized Factory Service Centers lists:

EMR (Electric Motor Repair)
2010 North 4th St.
Minneapolis, MN 55411
800-345-0198
612-522-3318

An insert with the manual also says you can call 800-328-2921 for the most current list of Authorized Service Centers.

Hope this helps. __________________
Thanks!

Charlie
fish.gif

Jul 16, 2010 | Garden

1 Answer

The motor runs continuously and the pressure is low. What are the possible causes for this?


You haven't given any model number information, but typically on any air compressor if it won't build pressure, either you have a leak in your piping, tank, hose or the compressor cannot move the required cfm of air. Could be a valve problem or piston, relief valve? Do you hear any air leaking. There are som many different models from cheap throw away compressors to thousands of dollar models. HArd to say without more information

Jul 19, 2010 | Dayton Audio Dayton Speedaire Air...

1 Answer

I have a dayton 1 1/2 h.p electric motor, and need the wiring diagram for 460 volt. the part number is [1] 3n013bb. thanks


Line is L1 L2 L3 to line voltage. wire nut 4-7 together wirenut 5-7 together and wirenut 6-9 together connect 123 to line for low voltage 123 together 456 together 679 together. This works on all dual voltage 3 phase motors. Some of the newer Daytom motors have a plug that you just turn for changing voltage. Rudty

Jun 03, 2009 | Heating & Cooling

1 Answer

My verticle vt631402aj compressor motor boggs down before pressure can reach 15 lbs.


hi your problem sounds tp be associated with your nonreturn valve this is not sealing ,allowing pressure to flow back to your pump from your reciever/tank ,this is a"service part"and do require replacement periodically
hope this is of help ian

Dec 29, 2008 | Chicago Forge AF5HV 30 - Gal. 5.0 - HP...

Not finding what you are looking for?
Dayton Permanent Split Capacitor Motor Fan Logo

Related Topics:

83 people viewed this question

Ask a Question

Usually answered in minutes!

Top Dayton Dryers Experts

Jay Finke
Jay Finke

Level 3 Expert

1338 Answers

Piyal Perera
Piyal Perera

Level 3 Expert

528 Answers

Gene Haynes

Level 3 Expert

5089 Answers

Are you a Dayton Dryer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides