1 Answer

Switch on fridge and compressor runs for a few seconds and then stops, switch off for a few minutes and then switch on again and it runs for a few seconds. Checked thermostat and seems to be OK

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • AEG Master
  • 43,501 Answers

Hi,

Many times a freezer and/or refrigerator do not work right because of a dirty condenser coil...there are also many other things that can go wrong.


If you are hearing a clicking or buzzing then check out the last two tips.

If your refrigerator is running but warm, then...

Check out these tips that I wrote about that... it is a great place to start trouble shooting your unit...and something that you can do rather then calling a repair person to do a simple thing for you...

Refrigerator Condenser Coil Cleaning Refrigerator Repair

Refrigerator Troubleshooting Refrigerator Compressor

Refrigerator Compressor Start Capacitor and Start Relay


Refrigerator or Freezer not Cooling or Getting Cold

heatman101

Posted on Mar 18, 2011

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Fridge appears to be dead. No lighting, no temperature display, silent. When unplugged and plugged back in, everything functions as it should...for a couple minutes! Then it goes silent and dark again


call a technician as it could be a control board problem or a start run capacitor that is over loading the electrical side and throwing the thermal overload switch

May 20, 2016 | Refrigerators

1 Answer

Refridgrator's compressor run for few seconds and stop. No cooling


That is called short cycling and caused by a defective start relay, overload, run capacitor, defective fan motor or defective compressor and of course it needs to be diagnosed to have the fridge cooling again
APPLIANCE 911

Dec 03, 2015 | Refrigerators

1 Answer

Hi, was wondering if you could help. I have an Electrolux fridge Model ER6632I that has suddenly stopped cooling. This fridge is approx 8 yrs old. I opened up to the rear of fridge and found that...



Seems that the compressor has some fault within the unit as it takes in more current under pressure. Sometimes it can be due to fault within the compressor, failure of the valve , O-rings. Now shut down the fridge for about 6 hours and then plug in the fridge to start. Observe cooling to happen in about one hour and ice to from under three hours.
Earlier make sure that the thermostat was set to normal mode for freezer and fridge. If there is no ice formation we have a big issue as the compressor and gas must be checked out. , if RPM of motor is low check capacitor.
.
Please check this link for tips :

http://www.espares.co.uk/advice/fridges-and-freezers/a/2

Jul 25, 2011 | Refrigerators

1 Answer

Problem has returned to Maytag fridge


I note this is a very old post. The compressor is not starting and what you were hearing was the PTC relay energizing followed by the KilXon thermal overload kicking off the compressor start sequence. What happens is that the PTC relays sometimes get a heated contact. Due to the weakened state of the contact it can cause a buzz. Even with a goo PTC relay you would hear the compressor buzz if it was not starting. In that case the run capacitor may have failed or the compresor rotor is internally locked at which point the start cycle will repeat every 3 to 4 minutes as the thermal overload cycles and the compressor will not start.

Thanks for choosing FixYa

Kelly

Jun 18, 2008 | Refrigerators

2 Answers

Refrigerator buzzing for 10 seconds every 4 or 5 minutes


Buzzing is usually a fan, like one in the freezer, or back bottom - for cooling the freon. The compressor over-heat usually will make a single click (off) and a few minutes later a click (on). If the fan in the freezer stops working well, the freezer will frost up and the fridge section will not be cold enough.

Apr 20, 2008 | Refrigerators

1 Answer

Fridge compressor problem ?


Seems to me you have a faulty cold control. (behind the temp control).Not too expensive , about 40 bucks.

Feb 23, 2008 | Refrigerators

2 Answers

Hisense air conditioner


-If both compressor and fan motor starts and stop, thermostat is the defect.
- If only the compressor check for your outlet no sign of discoloration, check the voltage if normal, check the defective overload protector of the compressor it its external, or compressor itself is defective

8fa8bfe.jpg

Oct 26, 2007 | Heating & Cooling

Not finding what you are looking for?
Refrigerators Logo

Related Topics:

388 people viewed this question

Ask a Question

Usually answered in minutes!

Top AEG Refrigerators Experts

ashburton

Level 3 Expert

417 Answers

Ian Jones

Level 2 Expert

77 Answers

David Jewell

Level 3 Expert

454 Answers

Are you an AEG Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...