Question about Jenn-Air JGC8536 Gas Cooktop

2 Answers

Converted Jenn-Air JGC8536ADB from NG to LP according to manufacturer's instructions. When installing R rear LP orifice spud, dropped the spud into the body. Opened the bottom access panel to retrieve spud. GENTLY swept bottom, retrived spud, installed, and closed access panel. Now spark ignitor stays on constantly. Unplugged AC, replugged AC. Still stays on. It worked fine before I dropped the access panel. Any ideas?

Posted by on

  • Timothy Martin Mar 17, 2011

    Thanks for the advice. It all makes sense. However the unit is newly installed (although I stored it in a dry location about a year after I purchased it) and I don't think the spark module is bad (unless it was bad when I purchased it). No water has ever been near it that I know of. I'd like to do test of the switches you menmtioned on the valves but I cannot see them through the holes in the top panel and I can't determine how to remove the top panel. I'm still wondering if I messed something up when I opened the access panel on the bottom to retrieve the spud, even though I did it gently. I hoping you can tell me how to remove the top so I can see inside. What do you think?

×

2 Answers

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Genius:

    An expert who has answered 1,000 questions.

  • Master
  • 1,622 Answers

Hi,
: ignitors spark continuously regardless of
: whether any burners were on or not.
That symptom could be caused by moisture in one of the ignition switches that is mounted on the burner valves, a shorted ignitor wire or a defective spark module. The range would have to be examined to determine which was the cause.

It's quite possible. It may dry out on its own or be helped by using a hair dryer on it/them (after removing the knobs). In some cases the switch(es) may still need to be replaced if drying doesn't solve the problem or if they only work intermittently afterward due to residual moisture or contamination of the switch contacts.

You can also use the link below for more understanding


fixitnow.com/2004/09/appliance-repair-revelation_17.htm


and

fixitnow.com/wp/2004/09/17/appliance-repair-revelation-troubleshooting-gas-stove-burner-ignition-problems/

Posted on Mar 17, 2011

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Brigadier General:

    An expert that has over 10,000 points.

  • Master
  • 3,513 Answers

Hi


Check one of the switches on the gas valves is shorting due to moisture probably. Check the little switch that is behind the burner knob either went bad or got water in it. To isolate the switch that is the problem you can pull one of the wires off of behind the burner knobs one at a time till it stops. If you pull a wire from each switch and it still goes on, then the spark module is bad. You will need to replace it. However it is normal for all the burners to spark whenever another one is being lit. Also too much dirt and grease can cause the burners to light hard but will not cause the spark module to keep on sparking all the time. If a burner lights hard, check the tip of the spark electrode to make sure it is clean.

If your spark module has burnt out to rapidly, or needs to be constantly replaced, you may not have a properly wired and grounded receptacle. Reversed polarity or not being grounded can cause the spark module to fail prematurely. Make sure that you do not use a two pronged outlet or extension cord for your range.

Please get back to us if you have further query else please accept the suggestion.

Thank you for contacting fixya.com

Posted on Mar 16, 2011

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Jenn air model 720 0061 manuel


Jenn Air model 720 0061 LP outdoor grill manufactured 12/ 2004 serial DG-002
I have bought this second hand. Would like operating , maintenance, and parts info.

Mar 31, 2014 | Jenn-Air Outdoor Liquid Propane Lp...

1 Answer

The regulator seems to be closing off completely, and not flowing gas (LPG). We have converted cooktop from natural gas to propane per instructions manual -- changed orifice spuds, converted regulator and...


I HATE TO TRY AND EXPLANE THIS FOR FEAR SOME THING MAY GO WRONG DID YOU FOLLOW THE INSTRUCTIONS TO THE LETTER. FROM NATURAL GAS TO LP YOU SHOULD OF HAD TO CHANGE THE POSISTION OF THE ORVICE IN THE REGULATER THAT IS WHY YOU ARN'T GETTING THRU THE REGULATOR CHECK YOUR DIRECTIONS AGAIN SOME TIME YOU HAVE TO THIGHTEN THE NUT ON THE REGULATOR SO IT DISTORTS THE ORFICE TO LP, AND SOME MODELS YOU HAVE TO TURN THE ORFICE OVER. BECAREFUL AND TRY AGAIN

Feb 06, 2011 | Maytag MGC5430 Gas Cooktop

2 Answers

Hi I am trying to convert my Dacor stove/oven from NG to Propane. We can't find the conversion kit anywhere. Any ideas?


Hi, to convert from NG to LP is easier in some ways but harder in others. The pressure part is easy because LP runs at the same pressure that comes into the house so the regulator is normally locked wide open to allow a direct by-pass. You could just as easily remove the regulator and plumb straight in from the houseline. You don't say what model but usually the sealed cooktop burners will need smaller orifices and the oven and broiler orifices are adjustable. If that is the case, the oven and broiler orifices can be tightened until they bottom out which be the correct output for LP. You would need to remove the cooktop orifices and find replacements which are correct for LP, these are non-brand specific. Honestly, if you go to repairclinic.com and enter the brand and model number, I'd be surprised if you couldn't find the conversion kit. Even the Dacor site should be helpful. I found many different kits available at the repairclinic.com site even without a model number. Best of luck.

Jan 29, 2010 | Dacor Preference SGM365SS Gas Cooktop

1 Answer

Soot deposits from my brand new downdraft jenn-air gas cooktop


Is this on LP or Natural gas? If LP was it converted to LP? In any event,The air shutter must be adjusted on the gas burner tube. You need more air. The valve orifice may also need adjusting.

Sep 28, 2009 | Jenn-Air JGD8345 Gas Cooktop

1 Answer

Converting cooktop regulator from NG to LP


LP is higher in pressure than NG, so regulator spring pressure has to be greater.

Aug 06, 2009 | GE Cooktops

1 Answer

Can a dacor range be converted from natural gas to LP liquid propane ??


I will trade you parts. I have the NG version and need to switch to LP.
Email me at adjuster@me.com.
Thanks

Jul 10, 2009 | Dacor Preference SGM365SS Gas Cooktop

1 Answer

Large yellow flames after the oven is on and getting up temp


The needle maybe damaged or missing inside of the hood, unscrew the hood and remove it, look at the needle and make sure it is intact, put a little liquid soap into the hood threads and screw it back on until it bottoms out, it will be much easier to feel it bottoming out if it has lube on it, if this does not work, call them and have them send you a LP specific hood rather than the adjustable type.

Jun 13, 2009 | General Electric PGS975SEMSS 30 in. Gas...

1 Answer

How can you tell which fuel a gas cooktop is set up for?


the gas regulator has a round "plug" in the middle of the top and one side is marked nat an one is marked lp you can tell which fuel the regulator is setup for by inspecting this plug. the orifices for the surface burners are marked with thier sizes (.073) for instance which I believe is thousandthsof an inch. also the orifice "spuds" as they are called will often have a drop of colored paint on them to further identify them for installation in the correct burner. checkyour carburation too. if the flame is noisy and trying to shoot up of the burner you could be getting too much air. close the air off a bit till you make a pretty flame two tone blue no yellow.

Aug 09, 2008 | Cooktops

1 Answer

LP Conversion for Jenn Air CVG316 (about 10 years old)


I have the same stove and I got the LP Conversion Kit at Sears Part Direct.:
http://www.searspartsdirect.com

Thisis the Part Number for the LP conversion for the Jenn-Air CVG316B: Part# Y04100687

Hope that can help you
Eddie Rentas
Tupper Lake NY

Nov 21, 2007 | Jenn-Air Cooktops

1 Answer

Convert to LP?


If it is possible, then the orifice has to be changed. The regulator may need to be changed as well. I am a certified LP technician for recreational vehicles, but I don't know enough about this particular appliance to say for sure if it can be converted. The best thing is to contact Miele directly, but this sort of conversion always requires a different orifice. Note that propane, butane, and natural gas are all forms of LP (Liquified petroleum), so conversion between the 3 is usually possible

Oct 15, 2007 | Miele 35 in. KM326G Gas Cooktop

Not finding what you are looking for?
Jenn-Air JGC8536 Gas Cooktop Logo

Related Topics:

188 people viewed this question

Ask a Question

Usually answered in minutes!

Top Jenn-Air Cooktops Experts

yadayada
yadayada

Level 3 Expert

74896 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

paulcarew

Level 3 Expert

2454 Answers

Are you a Jenn-Air Cooktop Expert? Answer questions, earn points and help others