Question about DeLonghi Pinguino PACL90 Portable Air Conditioner

1 Answer

Hot Air doesn't seem to cool

Posted by on

1 Answer

I am assuming it's turned on, and plugged into electricity, but at that point I have no idea what you are doing to try to cool the air, as in, what settings do you have it on?
Does the front indicator panel, led lights, have any signals indicated?
Are you exhausting air out of the room, and using both exhausts?
Are the exhaust lines straight? Pointed upward or downward? Sideways kinked?
Are there Hard S's in the exhaust lines that would cause backup of air flow?
Has a family of small penguins (very small) moved into the exhaust hoses, thereby blocking flow?
What is the actual temperature before use, and during use after a given amount of time and at what is the outside ambient temperature?
Did You lay it down or sideways before turning it on, or has it always been in the upright position?
Is the filter clean?
Have you cleared out the drainage hoses? They may be backed up.
Are your vents open?

Air in, air out.


try leveling or having the exhaust hoses point down and not up to exhaust.


Posted on Sep 17, 2008

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Unit not working correctly. The unit worked for the winter, few days ago I turn on the AC and noticed that it wasn't cooling like it should.


It's could be the board or a heat relay. See if you have 24 volts on "x2" im assuming, emergency heat when in cool mode if so it's the board. Or unhook black or x2 or your emergency heat from board and run unit in cool. If heat stays on its a relay

Jun 02, 2016 | Heating & Cooling

1 Answer

I have a Haier Wall Air Conditioner. It's on cool


Filter may be clogged. I have one and it has a filter which I clean regularly.

Sep 11, 2012 | Heating & Cooling

1 Answer

No cooling and no air going out the exhaust


COULD BE THE motor froze. Usually the same shaft does the cool side and the hot side does either fan spin freely. Have to admit oil usually doesn't fix it longterm

May 15, 2012 | Amcor ALTL-12000E Portable Air Conditioner

1 Answer

Power button indicates a cooling mode but I don't hear the compressor come on and the air coming out is not cool. Seems to have worked earlier this summer but sometimes the cooling seem spotty. Tried...


You may not have the temperature set low enough to make the compressor turn ON. Lower the setting until it does. This will give you an indication, where you need to leave it set.

Thanks for choosing FixYa.

Aug 27, 2011 | Amcor ALD12000M Portable Air Conditioner

1 Answer

Ive owned the 10x6c for 2 years never used it because of my wiring doesn't have a ground,,let my neighbor borrow it and it doesn't blow cool air I hear the compressor turn on but no cool air?


If the compressor is coming on and the air is not cold, it could be that the freon has leaked out. Easiest way to check for no freon is to take the cover off the unit and run it in cool. The high side which is the smaller line coming into the top of the compressor should be hot, and the low side which is the large line coming off the side of the compressor should be cold when the compressor is running. If there is no temperature difference between the high side and low side tubing, you have no freon. Also check for oil residue once you have the cover off. If you spot oil, you had a leak and have no freon.

Aug 14, 2011 | Haier hwr10xc6 Air Conditioner

1 Answer

Sharp AF-M808X air conditioner. suddenly there is only fan air movement. there is no longer any cooling; turning the thermostat knob to a higher level doesn't "kick in" the coolant. but...


Simple test: the thermostat in your unit is electromechanical - unplug the unit from the mains, take it out and measure the resistance between the 2 electrical contacts, if it doesn't goes to near 0 when you turn it even a little bit then it's defective and it will have to be replaced.
If the resistance does indeed goes to near 0 then the defect is in the AC system. Another simple test: open the casing of the unit and put your hand directly on the compressor; now turn the thermostat button. If it doesn't vibrate then the starting capacitor of the compressor has failed and it will have to be replaced with a similar one.If it vibrates then the cooling circuit has got a leak and all the fluid has been lost. For that you will have to call a pro that will solder the leak shut and refill the circuit with the appropriate fluid - only he will have it, it's not sold on the customer market.

Jul 22, 2011 | Sharp AF-M808X Air Conditioner

1 Answer

The air from my air conditioner doesn't seem to be coming out as cold as it was when i first bought it. It seems to take a lot longer to cool off my living room, i dont know if it needs freon to be...


Its going to take a hile to cool down a hot room . have you cehck the filter? while your at it wash it out . what is the temp of the room and the temp of the air coming out of the unit?

Jul 22, 2011 | Goldstar Heating & Cooling

1 Answer

The unit only blows out hot air. It doesn't switch to ac mode @ all. What is the problem?


Make sure the control or the remote has actually changed the mode setting to cool function. Try new batteries if necessary or see if the main unit has an overide or manual control to select cooling only. It may be that the compressor is not running at all. The hot air you are feeling may be the room temperature air... Can you hear if the compressor is running or is it just the fan ??

If it is still stuck on heat mode, the reversing valve may be jammed.

Jul 03, 2011 | Royal Sovereign ARP-3012 Air Conditioner

1 Answer

AIR DOES NOT SEEM TO BE COOL ENOUGH LAST YEAR HAD SERVICE COME AND PUT FREEON IN


hi,
If the the AC doesn't get the cooling then the main reason will lack of freon gas.
Is the fan works perfectly. Also check the fan is it working perfectly. If the fan is ok then you have to refill the freon gas again.
ok

Jun 09, 2011 | Frigidaire FAL125K1 Air Conditioner

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

91 people viewed this question

Ask a Question

Usually answered in minutes!

Top DeLonghi Heating & Cooling Experts

kakima

Level 3 Expert

98796 Answers

paulcarew

Level 3 Expert

2046 Answers

Cindy Wells

Level 3 Expert

4804 Answers

Are you a DeLonghi Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...