Lantronix UDS1100 what are the pin connection to emulate com1 on a PC

Posted by on

  • TechLoHope Mar 15, 2011

    Thank you Ardmax, The connection mentioned on Page 72, as I understand it, is for programming the unit from the serial port, what I am struggling to do is emulate a serial port, which pin on the uds1100 should go to which pin on 9 pin male connector

×

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

    Scholar:

    An expert who has written 20 answers of more than 400 characters.

  • Expert
  • 155 Answers

Please see the link here below for the complete manual.
http://www.lantronix.com/pdf/UDS1100_UG.pdf

If you go to page 70 you will see the complete pin layout for RS232, if you need to connect it to a PC with a 9 pin RS232 port you can see the equivalent on page 72.

Please let me know if you need more details.

Posted on Mar 15, 2011

  • Massimo Ardito
    Massimo Ardito Mar 15, 2011

    Dear TechLoHope,
    You are right but...the serial port you are talking about is bi-directional.
    You can use the serial port to program the unit, to be a converter from serial to ethernet and to convert from ethernet to serial. Fig. 2.1 should help you to understand what I mean.

    When you are saying that you are struggling to make it work I'm wondering about the application. We use devices like this one and other vendor like Moxa to interface drives, PLC, scanners, etc..., located miles away on a VPN.

    What you have to pay attention to is the pinout yes, but the configuration also (Baud rate, parity, etc..).

    To program this device I recommend you to use the web interface, it should be easier, then be sure you have installed the virtual com or com emulator on the PC you try to use to communicate with the device connected to the serial port.

    Before I continue let me know if it is clear up to here.

    regards

×

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

How to connect 34pin floppy emulator for 24 pin floppy driver?


best to buy a floppy disk drive with direct USB cable to avoid all these problems and is recognised by PC for booting etc. No emulation required.

Oct 06, 2014 | Computers & Internet

1 Answer

How do I open COM1 in Windows 7 Pro?


Com1 is the Communication Port. A serial Port located on the computer and usually 9 pins.

Feb 18, 2014 | Computers & Internet

1 Answer

Problem with serial interface com1 in N15235


Look at your motherboards manual to see the pins.Configuration of COM's are Bauds 115.000 Bits 8 Parity N (none) Stop bits 1
as standard

Feb 07, 2012 | Foxconn 6627MA-RS2H Motherboard

1 Answer

Hi. I have to configure the lantronix mss-100, bat I dont have the cable.


Hi,

Are you asking about a serial cable to connect the serial port on the MSS100 to (for instance) a Com port on a PC?

If that's the case you can use a DB9-to-DB25 null modem cable. Here's an example: http://www.cablestogo.com/product.asp?cat_id=936&sku=03019

You will also need a DB25F/F gender changer in order to use this cable.

If the MSS100 already has an IP address that is valid on your network you can telnet to it or open it's web configuration manager in a browser to configure it.

There are video tutorials of various ways to assign an IP address to an MSS here: http://ltxfaq.custhelp.com/cgi-bin/ltxfaq.cfg/php/enduser/std_adp.php?p_faqid=1114

There is also a FAQ: http://ltxfaq.custhelp.com/cgi-bin/ltxfaq.cfg/php/enduser/std_adp.php?p_faqid=167

Installation and configuration information is in the Installation and Getting Started chapters of the MSS User Guide, http://www.lantronix.com/pdf/MSS_UG.pdf

If you have further questions, please give Lantronix Technical Support a call at 800-422-7044, or post a question here: http://ltxfaq.custhelp.com/cgi-bin/ltxfaq.cfg/php/enduser/ask.php

Regards,

Gary Fisher
LANTRONIX
Senior Technical Support Engineer
167 Technology Drive, Irvine, CA 92618
Phone: (800) 422-7044 or (949) 453-3990

Post Technical Support questions at http://ltxfaq.custhelp.com/cgi-bin/ltxfaq.cfg/php/enduser/ask.php

Get real-time help online! Use Live Assist at http://www.lantronix.com/support/live-assist.html

Mar 10, 2010 | Lantronix (MSS100-21) (MSS10021) Remote...

1 Answer

Connected to a Serial Modem. Getting humming on


its due to motherboard problem.
install ur chipset driver

Oct 26, 2009 | Lantronix UDS1100 (UD110000201)

1 Answer

I have connected Lantronix UDS1100 Device with Siemens AZL Meters. But not able to get complete data on front end.


The UDS has the following LEDs, which help you diagnose problems.
Power LED (green)
Ethernet 10/100 Link (yellow = 10 Mb/green = 100 Mb)
Ethernet Half/Full Duplex Activity (yellow = Half Duplex/green = Full Duplex)
Diagnostic (red)
Status (green)
Simultaneously lit Diagnostic (red) and Status (green) LEDs mean something is
wrong. If the Diagnostic LED is lit or blinking, count the number of times the Status
LED blinks between its pauses. The following table explains the LED functions:

9bf7508.gif

Aug 27, 2009 | Lantronix UDS1100 (UD110000201)

1 Answer

Cash Drawer Command


The cashdrawer is SERIAL, you'll need to connect it to a COM port. The
software you're using has to be capable of sending data to the COM port
the cashdrawer is connected to when the cashdrawer needs to be opened.
From the site you mentioned:

Be sure drawer lock is not engaged.
Exit your system to a DOS prompt. Type the following commands (substitute
the correct com port for com1):
c:\>mode com1:300,n,8,1
c:\>echo "000000000000000000000">com1
The cash drawer should open.

About the cashdrawer RJ11 connection on the printer: You can connect any
solenoid driven cashdrawer to this port. The port uses pin 2 and 4 for
the voltage output, which is normally 24V on Epson receipt printers.
Sending a specific ESC character (every POS software should be capable of
doing this) to the printer will be recognized by the printer and the
printer puts 24V on the 2 pins mentioned for 300ms and voila, the drawer
opens.

Jul 12, 2008 | Epson TM-U220 Matrix Printer

1 Answer

Lantronix UDS 1100 freezing my software and hardware


I would check your flow control on both the device and on the UDS1100. Also make sure your baud rate, stop bits and parity match

Oct 24, 2007 | Lantronix UDS1100 (UD110000201)

1 Answer

Hyper terminal with IBM NWAYS Router 2210 Model 12E.


Hi Viki, I use HyperTerminal to configure my HP switches and a few other devices but typically they use a *special* manufacturer cable. I suspect that may be a problem you?re having; do you get any communications from the router via HyperTerminal? If you?re sure the cable is correct you can try the following configurations in HyperTerminal: -Start HyperTerminal *HT* with Com1 *if that?s what you?re using*connected to you console or data port on your router using the appropriate cable. - Create a new *location* in HT and name it something appropriate. - When the *connect to* box appears make sure you change the *connect using:* field to Com1 or whatever port you?re using* .-In the Com1 properties make the following changes: bps=9600; data bits = 8; parity = none, stop bits = 1 and flow control = Xon/Xoff. -Next click on file, properties then the settings tab. Set emulation to VT100 If this doesn?t work I would look seriously at your cable. Let us know if you have any more questions and as always please don?t forget to rate the posting.

Jan 16, 2007 | IBM NWAYS Router 2210 Model 12E

Not finding what you are looking for?
Lantronix UDS1100 (UD110000201) Logo

Related Topics:

923 people viewed this question

Ask a Question

Usually answered in minutes!

Top Lantronix Computers & Internet Experts

David Gust

Level 2 Expert

61 Answers

Doctor PC
Doctor PC

Level 3 Expert

7733 Answers

Are you a Lantronix Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...