Question about Sony Televison & Video

1 Answer

The STANDBY indicator is flashing red.The indicator flashes 8 times and then there is a break of about 3 seconds;then it carry on like this. Please Help.

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Brigadier General:

    An expert that has over 10,000 points.

  • Master
  • 8,909 Answers

Problem with the audio (AUDIO), unit goes to standby and blinks the self-diagnosis code. Check IC406 audio amp, PS401, and 402. On some projection models of Sony TV sets, this code means that T8005 (flyback transformer), or the associative components in the high voltage circuits are defective on the D board.

Posted on Mar 15, 2011

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Media receiver "on" button flashes 8 times and turns the Pioneer TV to standby.


These blinks [flashes] are fault indication (Error Codes). From the number of blinks occur at one time switch ON, you can get an idea about the faulty circuit section inside it. This will make repair easy. These are called blinking codes. Make sure about the exact number of blinking of the standby/power LED, by switching On & OFF the set, for at least two times. Count it carefully. If you wish to get some details, check the site linked here. It has details about blinking codes, and fault locating procedure, to many popular brand TVs and other devices. http://electronicshelponline.blogspot.com/

Oct 14, 2015 | Pioneer Televison & Video

1 Answer

Red flashing light


  1. Five blinks - AKB circuit (automatic kine bias), the timer/standby indicator blinks for about 30 seconds then goes to the self-diagnosis function. Something is wrong with the video. Check video out, Q705, 732, 761 and other components on the C board, also check Q218, 219, 220 on the A board. In addition, unit could be in IK blanking, try turning up screen slightly.

Jul 17, 2013 | Sony Televison & Video

1 Answer

Sony bravia KDF-50E2010 RED LIGHT FLASHES 4 TIMES THEN 3


Sony TV LED & Blinking Codes - What Does It Mean When Standby/Timer Light Flashes Sony has provided a "self-diagnosis function" with your TV, that in the case of abnormalities or problems the LED or red blinking light on the Timer/Standby indicator flashes a number of times to indicate the issue.
when there is trouble with your Sony Television set -- it indicates the issue in either the diagnostic mode, or even more commonly by flashing a series of LED blinks or flashes on the front of your television. Each set or frequency of the blinks indicates a very specific problem with the television itself.
Sorry but unless you may be able to repair the television set yourself , please call a local repair shop to the have a repairman sent out,,

Take care and please Remember to rate/vote for us to
continue f
or Helping out the Community :)

Jul 08, 2011 | Televison & Video

1 Answer

Heard a pop. Checked and had to replace the lamp. Now when turned on the power-standby flashes green, then flashes red, but TV never comes on.


How many times red light flashing?
This is an error code and red flashing count indicates a particular problem in specific section of tv, please count how many times red light flashing after 3 seconds long pause and post here to suggest a solution.
Thanks.

May 28, 2011 | Sony KDF-E50A10 50 in. LCD HDTV

1 Answer

Tv desn't turn on,power light just flashes ten times and then stops and then again


Error Indication Information
Error No. Error Information ERROR DESCRIPTION LAMP LED OSD LAMP OFF
(Note 3) (Note 4)
POWER LED TEMP LED
Note:
1.When any of the above errors has occurred, the LED will flash as shown above every 5 seconds.
2.When two or more errors have occurred at the same time, the LED will light up or flash as shown above, and then
change to another every 5 seconds in turn.
3.Warning OSD appears when the Air Filter is clogged 90%, accumulated operation time of the Lamp reaches 5000 hours,
or accumulated operation time of the Air Filter reaches 400 hours.
4.LAMP OFF: The LED will flash right after the Lamp goes off.
5.IC2301 is mounted on LCD Main C.B.A. which is included in the Projection Unit.
6.IC6001 is mounted on TV Main C.B.A.
Clogged air filter
more than 90%
15)
16)
17)
18)
1)
2)
3)
4)
5)
6)
7)
11)
8)
9)
10)
12)
13)
14)
- flashes 5 times -
every 5 seconds
IC2301(pin82) detects the clogged air filter, then indicates the
error when the air filter is clogged 90%.
Front Fan stop or
Lamp Fan stop
flashes orange
once every
5 seconds
- -
IC2301(pin12) detects the Front FAN stop or Lamp
FAN stop, then indicates the error when the Front FAN
or Lamp FAN is stopped.
Lamp Cover open
Temperature Sensor
short or open
flashes orange
twice every
5 seconds
flashes orange
3 times every
5 seconds
flashes green for
140 seconds.
flashing red for
60 seconds.
light up red.
flashes once
every 5 seconds
flashes once
every 5 seconds
flashes red for
10 minutes
flashes once
every 5 seconds
-
-
-
-
Abnormal
Temperature
flashes twice
every 5 seconds
flashes twice
every 5 seconds
- -
Request for Lamp
Replacement - - lights up
Power Ballast Error
(abnormal
Lamp voltage)
- -
flashes 3 times
every 5 seconds
Power Ballast Error
(abnormal
temperature)
- -
flashes 4 times
every 5 seconds
Power Ballast Error
(other causes) - -
- -
Request for Filter
Cleaning -
Abnormal Voltage
on 16 V line of
LCD Main C.B.A.
-
flashes twice
every 5 seconds
flashes twice
every 5 seconds
Abnormal Voltage
on 14 V line of
LCD Main C.B.A.
-
flashes 3 times
every 5 seconds
flashes 3 times
every 5 seconds
Abnormal Voltage
on 7 V line of
LCD Main C.B.A.
-
flashes 4 times
every 5 seconds
flashes 4 times
every 5 seconds
IC2301(pin76) detects the Lamp Cover Unit condition
(open or close), then indicates the error when the
Lamp Cover Unit is open.
IC6001(pin85) detects the Duct FAN stop, then
indicates the error when the Duct FAN is stopped.
IC2301(pin74 and 75) detects open or short of the Temperature
Sensor (R2911) on Front Thermistor C.B.A., then indicates the
error when Temperature Sensor is open or shorted.
(The error is not detected for 1 minute after Lamp ON.)
IC2301(pin74 and 75) detects the temperature attached near
the Front FAN by the Temperature Sensor (R2911) on Front
Thermistor C.B.A., then indicates the error when the
temperature becomes more than 43 C (109 F).
(The error is not detected for 1 minute after Lamp ON.)
IC6001(pin86 and 87) detects open or short of the
Temperature Sensor (R2901) on Lamp Thermistor C.B.A.,
then indicates the error when Temperature Sensor is open or
shorted.
(The error is not detected for 4 minutes after Lamp ON.)
IC2301(pin74 and 75) detects the temperature attached near
the Lamp by the Temperature Sensor (R2901) on Lamp
Thermistor C.B.A., then indicates the error when the
temperature becomes more than 60 C (140 F).
(The error is not detected for 4 minutes after Lamp ON.)
IC2301(pin11) detects the error of LCD Power C.B.A.,
then indicates the error when the temperature fuse
(117 C)(243 F) in LCD Power C.B.A. is open.
IC2301(pin11) detects the error of LCD Power C.B.A. and Lamp,
then indicates the error when an inner malfunction of LCD Power
C.B.A. occurs, the Lamp voltage becomes more than 130V or
less than 30V, Lamp current becomes more than 5A, or the Lamp
is cracked.
IC2301(pin11) detects the error of the Lamp, then indicates the
error when the Lamp is short-circuit.
IC2301(pin48) detects +16V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +13V.
IC2301(pin47) detects +14V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +11V.
IC2301(pin45) detects +7V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +5.7V.
IC2301(pin44) detects +3.3V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +2.5V.
flashes 3 times
every 5 seconds
flashes 4 times
every 5 seconds
Abnormal Voltage
on 3.3 V line of
LCD Main C.B.A.
-
-
-
- flashes 5 times
every 5 seconds
Forced cooling
The failure of Lamp
light up
-
Temperature Sensor
short or open
-
-
Abnormal
Temperature
Duct Fan stop -
When accumulated operation time of the the Lamp reaches
5000 hours, OSD (replacing the Lamp) appears on the screen.
Note: The Lamp time is stored in EEPROM (IC2305).
When accumulated operation time of the Air Filter reaches 400
hours, OSD (cleaning the Air Filter) appears on the screen.
Note: The Filter time is stored in EEPROM (IC2305).
During forced cooling, this indication is indicated.
IC2301 (pin11) detects the failure of light up processing of
the Lamp, then the POWER LED is changed as follows.
1) POWER LED flashes green for 140 seconds (while turning on).
2) POWER LED flashes red for 60 seconds (while cooling).
3) POWER LED lights up red (standby).
Note: If the Lamp will not light after attempting turning on the
power 2 or 3 times, the Lamp, the LCD Power C.B.A. or the
LCD Main C.B.A. may be defective.
Error Symptom Problem Possible Solutio

May 30, 2010 | Panasonic Viera TH-50PX80U Plasma TV

1 Answer

Standby Indicator flashes red 6 times between 2 second intervals


My TV (Sony Bravia LCD KLV-32S310A) goes of after 20 seconds when it is switched on. The standby indicator then flashes (red) five (5) times then there is a two seconds break followed by another six flashes then two seconds break etc. What might have caaused this and what should i do?

Apr 13, 2009 | Sony Televison & Video

1 Answer

My TV (Sony Bravia LCD KLV-32S310A) goes of after 20 seconds when it is switched on. The standby indicator then flashes (red) six (6) times then there is a two seconds break followed by another six flashes...


Hi,
6 times blink shows problem with back light inverter board.
TV requires back light inverter board replacement. If you have electronics repair experience and want to repair TV by yourself, let me know to guide you part purchase.

Apr 13, 2009 | Sony KV-35S42 35" TV

1 Answer

SONY GRAND WEGA KF-50WE610 can't turn on TV screen.


Ths 5 blinks usually indicate an AKB problem. There is a break in the video path. I'll look up your specific model and post the results here. Please update this if you wish to attempt the repair yourself.

Thanks,
Dan

Mar 19, 2009 | Sony Grand WEGA KDF-55WF655 36" Rear...

1 Answer

Standby light flashes 3 times


A 3 flash pattern indicates that either the lamp is not seated correctly or that the lamp door is not latched properly. It can also be a fault with the switches that sense whether the lamp is seated or the door is latched. Try reseating the lamp and relatching the lamp door

Oct 20, 2008 | Sony KDF-E50A10 50 in. LCD HDTV

Not finding what you are looking for?
Televison & Video Logo

Related Topics:

162 people viewed this question

Ask a Question

Usually answered in minutes!

Top Sony Televison & Video Experts

kakima

Level 3 Expert

102366 Answers

The Knight
The Knight

Level 3 Expert

73665 Answers

Jerry Greenberg
Jerry Greenberg

Level 3 Expert

1667 Answers

Are you a Sony Televison and Video Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides