Question about Goldstar DH504EL Dehumidifier

1 Answer

My dehumidifier is only about a year old and the bucket full light keeps blinking. i turn it on, it sounds like its going to kick on but shuts off a second later.

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Sergeant:

    An expert that hasĀ over 500 points.

    Champion:

    An expert who has answered 200 questions.

  • Expert
  • 250 Answers

It sounds like the switch under the bucket is stuck. Remove the bucket and there should be some kind of switch where the bucket rests against. Make sure the switch works freely if not spray a little contack cleaner on it and work the switch by hand until it frees up.

Posted on Mar 11, 2011

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

3 Answers

My Zenith dehumidifier model #zd300 will not work. It is only one year old and worked fine when I shut it off for the winter. Now when I plug it in the full bucket light blinks and the humidifier setting...


I had the very same problem with my Zenith ZD300 dehumidifier. After getting no help from the manufacturer and realizing that it was going to cost $45 just to figure out what was wrong with it, I dismantled the dehumidifier myself in search of a solution. I suspected it was the humidity sensor, so I ordered the part off Repair Clinic website (repairclinic.com). It cost $18.20 plus shipping. AND IT WORKED!! I was so relieved that I wouldn't have to buy a new dehumidifier. It's been running for a day now, so we will see. Here's the website link:
http://www.repairclinic.com/PartDetail/Thermistor/6877A30013R/1462299

Part info:Thermistor6877A3001R
Good luck!!

Aug 13, 2011 | Dehumidifiers

2 Answers

It will not turn on. Is there a reset button? It worked fine for over 5 years, then it just quit.


Hi, Sounds like the circuit board...they often will just do that...IF you can get one it will be half the cost of a new unit...
There are many reasons why a dehumidifier willnot work or collect water.
Here is a tip that I wrote to help people to figure out what is going wrongwith their dehumidifier

Dehumidifier is running but no water is in bucket

heatman101

May 19, 2011 | Maytag M7DH65B2A Dehumidifier

1 Answer

The unit is about 4 years old and the auto shut off light is flashing on and off and the unit will not run even tho the unit is empty can you help me out? Thanx Larry


Normal 0 MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman";} Hi,

Here is a tip that explains what can be happening to make the dehumidifier show that the bucket is full when it is not.

Dehumidifier Problem It shows Bucket Full

heatman101

Sep 01, 2010 | Kenmore 54351 Dehumidifier

1 Answer

LCD READS CH 1 SHUTS DOWN BUCKET FULL LIGHT COMES ON


lcd reads ch 1 shuts down bucket full light blinks red

Aug 04, 2009 | LG Goldstar LD65EL Dehumidifier

1 Answer

Auto shut off


Try re-seating the bucket. I have found some LG models that if not seated all of the way will sometimes keep running and think the bucket is not full even when it is. On the models that I have seen do it the problem is usually the left side of the bucket not engaging all of the way. When you reseat the bucket, feel where the bucket meets the dehumidifier on each side and make sure they are even. If one feels like it is sticking out further than the other and you cannot push it in any more pull the bucket out and try and reseat it again until both sides are flush with the dehumidifier. If you found this solution helpful please rate it.

Thanks - Tech101

Sep 08, 2007 | LG DH404E Dehumidifier

Not finding what you are looking for?
Goldstar DH504EL Dehumidifier Logo

88 people viewed this question

Ask a Question

Usually answered in minutes!

Top Goldstar Dehumidifiers Experts

Gil Shultz

Level 3 Expert

3368 Answers

Michael Youngman
Michael Youngman

Level 2 Expert

156 Answers

Jerry Greenberg
Jerry Greenberg

Level 3 Expert

1667 Answers

Are you a Goldstar Dehumidifier Expert? Answer questions, earn points and help others