Question about Grilling

1 Answer

Jenn-Air outdoor grill - model: 720-0150-LP

I can turn on and light 3 of the burners, but once I turn on the 4th they all go out.

Posted by on

  • Dragon07 Aug 05, 2008

    I have a three burner model. I have cleaned all three burner units. I can turn on with a match two of the burners but when I turn on the third they all go out???

  • SRC1 Aug 11, 2008

    Same problem, except the burners that light have a low flame and then all goes out when I light the last burner.

×

1 Answer

Your propane hose or tank has a leak and the regulator is restricting flow

Posted on Aug 22, 2008

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I Have A Jenn-Aie Model 720-0164 Natural Gas Grill. When I Grill, The Control Knobs Get So Hot Theyh Will Burn You. What Could Csuse This?


Can this grill be also used on propane? If so you might be running it too hot on natural gas, check to see if the control knobs have two different set of markings.

Sep 16, 2014 | Jenn-Air Outdoor Liquid Propane Lp...

1 Answer

Jenn air model 720 0061 manuel


Jenn Air model 720 0061 LP outdoor grill manufactured 12/ 2004 serial DG-002
I have bought this second hand. Would like operating , maintenance, and parts info.

Mar 31, 2014 | Jenn-Air Outdoor Liquid Propane Lp...

2 Answers

Loss of gas pressure to burners on Jenn-air Model #720-0062-LP


If you're confident that you have adequate gas in the tank. turn the tank valve OFF and disconnect the hose from the tank. Wait 5 minutes and reconnect the hose to the tank. Once connected, open the tank valve VERY, VERY SLOWLY (Slow motion, slow). Once the valve is fully open, light the burner farthest from the tank first and turn it to it's highest setting. Does the flame height look correct? If so, light the remaining burners the same way. Do all the flame heights now look correct? If so, you solved the problem. Remember to always open the tank valve very, very slowly.

If the above didn't solve the problem, you are either low on gas or the hose/regulator assembly needs to be replaced. If replacement is necessary, you can find the hose/regulator assembly at any home center or hardware store that sells gas grills and accessories. Take your old one with you for comparison purposes.

Hope this helped you solve the problem. Happy Grilling!!

May 02, 2011 | Jenn-Air Grilling

1 Answer

Grill will not stay lit if using 4 th burner will only work on 3 burners and gas is low


Check that the fourth burner tube is set properly into the unit. Then turn all burners off, turn off the natural gas supply or remove the LP tank. turn all the burners on (don't try to light) wait a couple seconds turn all burners off. reconnect gas source. turn on gas, open burners fully and try to light.

Aug 08, 2010 | Jenn-Air Grilling

1 Answer

Jenn-Air Model 720-0061-LP. Burners will not


burner is blocked needs cleaning out remove burner and clean it or put it in clr , or buy new one

May 18, 2010 | Grilling

1 Answer

Jenn-air model 720-0061 LP burners only light on one side cleaned with wirebrush and blew out with air?


The crossover for the flame to "jump" to the other side of the burner is clogged, rusgted, etc. It looks like a straight cut line on the rear under side of the burner. Nexgrill told me that the burners did not have an adequate amount of "finish" on them. Call them and get all new burners for free under warranty, Since 2004, I am on my 5th set of burners.

May 05, 2010 | Jenn-Air JLG7130A

1 Answer

Jenn Air gas grill model 720-0163 will not get above 180 degrees?


Try turning on just one burner to start, once it is on, turn on the next burner, if the flame gets lower on the first burner, you need to replace your regulator.

Dec 20, 2009 | Jenn-Air Grilling

1 Answer

What are the btu ratings for a jenn air model 720-0100 ng grill. i am converting this to lp gas...


does not matter just change out the orfices on all burners and back burner even if you have a IR buners, the orfices let enough gas in for your grill call jenn air they will sell you the kit to convert it over

Jul 29, 2009 | Jenn-Air Grilling

2 Answers

Grill jenn-air will not heat past 100 degrees


You need to pull the burners out and scrub open the side feedholes on the burner. These ususally clog up over time reducing the heat available for cooking. Also, sometimes the Gas regulator goes bad over time when left outside for a year or two. A bad regulator will put out less gas as it fails closed.

May 04, 2009 | Nexgrill 720-0234 (LP)

Not finding what you are looking for?
Grilling Logo

Related Topics:

1,006 people viewed this question

Ask a Question

Usually answered in minutes!

Top Grilling Experts

paulcarew

Level 3 Expert

2364 Answers

Dan Webster
Dan Webster

Level 3 Expert

8205 Answers

yadayada
yadayada

Level 3 Expert

70346 Answers

Are you a Grilling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...