Question about APC Back-UPS XS900 (BX900) UPS System

2 Answers

Ups problem ups can't be backup minimum 15min after power off ,what do i do?

Posted by on

2 Answers

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 3 Answers

You can check your battery using a voltmeter, but it is likely that you need a replacement battery. http://www.batteryinternational.com/ups-batteries.html should help you find the battery you need. Hope that helps

Posted on Jun 24, 2009

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Expert
  • 87 Answers

Hello , friend


please check ur battery

Posted on Jul 29, 2008

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

Apc hi800sq


follow this steps and fix it. God bless you
Plug the battery backup into a working electrical outlet. If the battery backup turns on when the power button is pressed, then the problem may be that the previous electrical outlet is faulty. Proceed to step three. If the battery backup doesn't turn on, proceed to step two.
  • 2 Reset the circuit breaker on the battery backup. APC battery backups have a labeled circuit breaker button located on the unit near the phone line, fax line, USB, network and coaxial cable inputs. Press the button to reset the circuit breaker. Power on the battery backup by pressing the power button. If the battery backup powers on, proceed to step three. If the battery backup doesn't turn on, proceed to step six.

  • Read more: http://www.ehow.com/how_7266444_troubleshoot-apc-battery-backup.html#ixzz2lwOvPO75
  • 3 Determine if the battery backup is charged and providing battery power. With the battery backup on and plugged into a working electrical outlet, plug a computer monitor into one of the battery backup outlets labeled "battery backup plus surge protection" on the battery backup. (APC power supplies have some outlets that provide only surge protection while the other outlets provide surge protection plus battery backup.) Turn the monitor on. Unplug the battery backup power cord from the wall outlet. If the monitor remains on, the battery is holding a charge, supplying electrical power and the battery backup is working properly. If the monitor goes off, proceed to step four.
  • 4 Charge the battery. Plug the battery backup into an electrical outlet and allow the battery to charge for 16 hours. This will fully charge the battery.
  • 5 Test battery charge. Once the battery is fully charged, repeat step three. If the monitor stays on when power is interrupted to the battery backup, the issue is solved and the problem resulted from an incompletely charged battery. If the monitor turns off when power is interrupted, the battery within the battery backup is faulty and needs to be replaced.
  • 6 Replace the battery backup unit. The unit itself is faulty. If the battery backup is under warranty, contact APC to request a replacement.
  • Nov 28, 2013 | Computers & Internet

    1 Answer

    The UPS in this office is out of order, message that appear on screen is 'UPS V OUT LIMITS' and 'Battery critical'


    follow this steps and fix it. God bless you
    Plug the battery backup into a working electrical outlet. If the battery backup turns on when the power button is pressed, then the problem may be that the previous electrical outlet is faulty. Proceed to step three. If the battery backup doesn't turn on, proceed to step two.
  • 2 Reset the circuit breaker on the battery backup. APC battery backups have a labeled circuit breaker button located on the unit near the phone line, fax line, USB, network and coaxial cable inputs. Press the button to reset the circuit breaker. Power on the battery backup by pressing the power button. If the battery backup powers on, proceed to step three. If the battery backup doesn't turn on, proceed to step six.

  • Read more: http://www.ehow.com/how_7266444_troubleshoot-apc-battery-backup.html#ixzz2lwOvPO75
  • 3 Determine if the battery backup is charged and providing battery power. With the battery backup on and plugged into a working electrical outlet, plug a computer monitor into one of the battery backup outlets labeled "battery backup plus surge protection" on the battery backup. (APC power supplies have some outlets that provide only surge protection while the other outlets provide surge protection plus battery backup.) Turn the monitor on. Unplug the battery backup power cord from the wall outlet. If the monitor remains on, the battery is holding a charge, supplying electrical power and the battery backup is working properly. If the monitor goes off, proceed to step four.
  • 4 Charge the battery. Plug the battery backup into an electrical outlet and allow the battery to charge for 16 hours. This will fully charge the battery.
  • 5 Test battery charge. Once the battery is fully charged, repeat step three. If the monitor stays on when power is interrupted to the battery backup, the issue is solved and the problem resulted from an incompletely charged battery. If the monitor turns off when power is interrupted, the battery within the battery backup is faulty and needs to be replaced.
  • 6 Replace the battery backup unit. The unit itself is faulty. If the battery backup is under warranty, contact APC to request a replacement.
  • Nov 28, 2013 | MGE NOVA AVR 1100VA Tower UPS 81111 UPS...

    1 Answer

    PULSAR 220F MINIMUM MILEAGE HOW PLZ TELL


    If you are talking about a used UPS, i would not bother with a used unit.
    I find if they are used 24hrs a day, when the electricity is tripped and the ups kicks in, they only last a couple of minutes.
    I would plug just the pc and monitor into the UPS sockets, and plug everything else into the ordinary sockets. You will get alot longer out of the battery

    Sep 04, 2010 | MGE UPS Pulsar EXtreme 2200 C - UPS (...

    1 Answer

    Tripp lite avr 550 ups keeps on discharging while power is still on


    Check the fuse. Check the input voltage. Since it's AVR, it keeps discharging if the input voltage is below the minimum

    Aug 05, 2010 | Tripp Lite AVR AVR550U UPS System

    1 Answer

    UPS does not supply power to equipment after power trip


    Some of the less expensive UPS devices have two sets of plugs.  One set provides backup power and the other set only provides surge protection.  You need to ensure that the devices for which you want backup power are plugged into the correct outlets on the UPS.

    Apr 20, 2009 | Computers & Internet

    3 Answers

    Dynex Te685avr backup battery doesnt work


    If the battery outlets do not work, typically the Dynex TE685AVR UPS (battery backup) just needs a new battery. These batteries usually last 3-5 years.

    The model of the battery is a WKA12-7.5F2 and can be purchased at: http://www.replacementupsbattery.com/Product_pages/wka12-75f2.html.

    Jun 26, 2008 | Dynex (TE685AVR) UPS System

    1 Answer

    After powering on, all non-graph LEDs keep blinking


    That meens that UPS dont have battery power for minimum time (2min). Unplug some devices so UPS load need to drop below 25% and lets UPS recharge battery

    May 31, 2008 | NEC APC Smart-UPS 1400 (050-01803-000) UPS...

    1 Answer

    Ups not switch to battery mode


    this is not from elevating transformer, fuse, batterys. the problem from charger card transitor is fail remove the transitor.

    Oct 03, 2007 | Powerware PowerRite Plus UPS System

    Not finding what you are looking for?
    APC Back-UPS XS900 (BX900) UPS System Logo

    Related Topics:

    109 people viewed this question

    Ask a Question

    Usually answered in minutes!

    Top APC Computers & Internet Experts

    Brian Sullivan
    Brian Sullivan

    Level 3 Expert

    27725 Answers

    joecoolvette
    joecoolvette

    Level 3 Expert

    5660 Answers

    kakima

    Level 3 Expert

    98694 Answers

    Are you an APC Computer and Internet Expert? Answer questions, earn points and help others

    Answer questions

    Manuals & User Guides

    Loading...