Have a Dayton Model #6K167, 230v, 34 A, 1740 RPM, 71/2HP. The Motor would just hum when turned on. Did some checking and found a wire lead off of one of the capacitors, But when I was tryng to connect the wire several other wires can off. I hook the wires up and bump the motor on. It ran but I smoked one of the capacitors. Not sure where they went. Need a wiring digiram showing how to connect capacitors. It has 2 running capacitors & 4 starting capacitors. Thanks Glen

  • 1 more comment 
  • glenfo Feb 16, 2011

    Hi Valeantudor. Looked at site you sent me. Only it didn't show how to connect the Capacitors, The 2 running Capacitors

  • glenfo Feb 16, 2011

    Hi, I need the wiring diagram that shows how the wire connection are made for the capacitors. There is 2 running caps, & 4 starter caps. The diagram that was on the site you sent didn't show this information. Glen

  • glenfo Feb 19, 2011

    Hi, I got the info that was provided. But it does show how to hook up or wire the capacitors. As I said before. There is 2 Running capacitors & 4 Starting capicators. There is 4 leads that go to capacitors from motor.The drawing just show 2 capacitor. Are they series or parallel or series /parallel connection. Please let me know as I need to get the motor running. Glen

×

2 Answers

John Prohaska

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

  • Master 1,378 Answers
  • Posted on Feb 17, 2011
John Prohaska
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

Joined: Jun 12, 2009
Answers
1378
Questions
2
Helped
688869
Points
3511

Glen,
We should be able to help you with your wiring issue but I will need one other piece of information off of the motor nameplate; the date code/derial number of manufacturers number. Depending on when it was made it will have one of these numbers which in turn identifies the age and therefore how it was connected at the factory. Once you have that information, or even better, send EVERYTHING on the nameplate either in an email or picture to:

[email protected]

It may take a little time to get the record from the tech department but we should get it.

Thanks,
John
Arrow Motor & Pump, Inc.

Tudor Valean

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

  • Master 787 Answers
  • Posted on Feb 16, 2011
Tudor Valean
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

Joined: Feb 15, 2010
Answers
787
Questions
0
Helped
158189
Points
2165
Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
2answers

I have a Dayton Electric Motor Mod. 6K610E Is this a Single or Three Phase Motor

single phase 240VAC. data late will have info. 3 phase usually has 12 leads.
0helpful
1answer

Could sure use a wiring diagram for a Dayton 5k961c motor.

Electric Motors: dayton motor, Electric motor repair Kansas ...

en.allexperts.com > Industry > Machine Tools > Electric Motors
Aug 24, 2010 - Electric motor repair Kansas City MEAR Service 816-650-4030: Tyler, it is ... i have a dayton motor with no wiring diagram. i need a wiring diagram for a dayton motor with a model # 5k961c and a reference # r67745ck733 ... 1992 Dodge Dynasty Blower Motor Wiring Diagram · 1998 Ford Escort Blower ...

wiring diagram (ideally color) for Dayton belt drive motor Model ...

www.electro-tech-online.com > ... > General Electronics Chat

Apr 29, 2012 - 9 posts - ‎3 authors
There is a sticker on motor indicating wiring, but seems only an. ... This is a motor for vented - big blade ceiling fan -- a belt driven Dayton Motor ...

DAYTON 1/4 HP Condenser Fan Motor,Permanent Split ...

https://www.grainger.com/.../DAYTON-1-4-HP-Condens...

W. W. Grainger
Rating: 3.8 - ‎6 reviews
Shop DAYTON 1/4 HP Condenser Fan Motor,Permanent Split Capacitor,1075 Nameplate RPM,208-230 ... Typical HVAC Condenser Fan Motor Wiring Diagram ...

DAYTON 1/3 HP Direct Drive Blower Motor, Permanent Split ...

https://www.grainger.com/.../DAYTON-1-3-HP-Direct-D...

W. W. Grainger
0helpful
1answer

Motor with no labels

3 phase motors that burn wire have a short in one of the phase wires that is allowing twice much current pass than is allowed. I would remove it and have a motor shop check it out.
1helpful
1answer

I installed a Dayton 4m205j condenser fan motor. It comes on but turns the wrong way. I switched the wires and it still turns the wrong way.

From what I can find on the internet, there should be a plug very close to the motor body that can be reversed to reverse the rotation of the motor. It should be a small rubber plug on the wires leading into the motor.
Also, check inside the wiring compartment for a sketch or notes.

Gary
0helpful
1answer

I got a dayton 2hp. electric motor model#2N982M it appears you can wire it for 110volts,220volts, or 440volts - need a wiring diagram mine partially worn off.

That motor is a three phase motor and will not run on 110 volts. It is also a high RPM motor with a lot of torque and MUST be mounted to a solid surface before it is powered up or it could rip your arm off as it flies across the room. If you have access to three phase power then you could power that motor but not with standard household electrical service.

Heres a link to some info for it
0helpful
1answer

I just bought a dayton model 4m098j direct drive motor i hooked up white wire and the black it hums when it turns it is realy slow i dont have any thing for the two brown wires to hook to can you help me...

Hi,
The brown wires go tto the capacitor...

Here is the page

http://www.grainger.com/Grainger/wwg/search.shtml?searchQuery=4m098&op=search&Ntt=4m098&N=0&sst=subset

On the top right of the page you will se that the cap. is a REQUIRED accessory....buy it and hook it to the brown wires and the motor will run...

heatman101
0helpful
2answers

ITEM: Dayton universal motor model 8mo38A 10,000 rpm spec number 6540 1.7 amps HP 1/5, Volts 230. PROBLEM: Motor used in small appliance with short on bursts and much longer off time but many...

My engineering experience tells me that this is likely caused by sudden acceleration or deceleration of the motor. Not knowing the type of load the motor is driving I can only point you to look for things causing sudden load changes. I would be tempted to install a soft start circuit or inrush current limiter that accelerates the motor slower or possibly install a flywheel to reduce acceleration/deceleration torque pulses. As a final suggestion, I would present the problem to the manufacturer of the appliance and the motor.
0helpful
1answer

Low rpm on blower motor

The 1350 RPM Speed is for 50HZ. The motor will only run at 1525 on 60 HZ.
0helpful
3answers

Dayton Attic fan running backwards

First see if the switch has a reverse position. Sometimes you turn the fan assembly in the frame, sometimes you turn the whole frame around. Take the cover off the wiring compartment to see if there are instructions there. Also check on the name plate on the motor, there may be instructions there. Attic fans are usually engineered to blow out.
Not finding what you are looking for?

239 views

Ask a Question

Usually answered in minutes!

Top Dayton Dryers Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66855 Answers

Steve Pack
Steve Pack

Level 3 Expert

7126 Answers

Are you a Dayton Dryer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...