it has been working fine, but since a week ago, i turn it on and works fine for a few minutes and shots off and displays a "E1", i reset it , turn it back on and does the same thing, how can i fix that?
The e1 code is a demand to clean the filter. It means the unit has been running for 720 hours. It does not mean anything is broken...unless it hasn't been running for 720 hours. That would mean the "clean the filter" timer is broken! There are 2 reset methods.
1) Unplug the machine. Hold down the power button while plugging it back in and wait until it beeps (for about 5 seconds). Let go of the power button. Unplug the machine again, then plug it in and try to use it as an air conditioner.
2) Unplug the machine. Hold down the Mode button while plugging it back in. Keep the mode button pressed until it beeps (for about 3 seconds). Let go of the mode button. The machine will start. Turn it off by pressing the power button. Resume trying to use it as an air conditioner.
If neither of these work, the "clean the filter" timer is broken and needs replacing.
my Air conditioner suddenly off and light in timer and air flow picture is on. when I want to On my...
(More)
my Air conditioner suddenly off and light in timer and air flow picture is on. when I want to On my AC is cannot to on. I'm already try turn off from the electricity, but it still cannot star the AC and the light is still on..
Sharp AH-APO9EVA plasma split unit air-con 2 years old compressor keep stopping every few minutes...
(More)
Sharp AH-APO9EVA plasma split unit air-con 2 years old compressor keep stopping every few minutes and then restart even when thermostat set at 18 C when fan set at low speed. Have checked all setting correct and even the temperature sensor replaced problem persist. If fan speed set high, compressor will not stop or stop less often. Any advise on what to do?