Question about Haier Heating & Cooling

1 Answer

Hi the compressor on my split air conditioning unit will not cut in .the indoor unit runs and the compressor light on the indoor unit lights up?

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

  • Expert
  • 95 Answers

If the system is appearing to turn on, but no compressor, Check the capasitor on the condensor unit. If you open the service panel, you can test the compressor by pushing in the contact switch. If you push the switch and all comes on, Replace the thermostat after checking to make sure the thermostat wires are not cut or disconnected. The capasitor usually looks like it is swelling if it has gone bad

Posted on Jul 21, 2008

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Why does my sanyo model KHS2472 has a red light blinking in heat mode and a green in cooling mode, does not work in either mode makes a gurgling sound when it tries to run?


Hi,
The red light indicates it's either heating or in defrost mode
Check the outdoor unit if the compressor is running - the large pipe on the outdoor unit should be hot on heating or cool to touch on cooling
When in heating mode - the indoor fan will not start until the indoor coil is warm enough
If the reversing valve that changes from heating to cooling is faulty then you may encounter the same symptoms too
Probably need a Refrig Tech to have a look at it?
Good luck

Jan 07, 2016 | Sanyo 24KS72 Split System Air Conditioner

Tip

Ductless Split Air Conditioner Review


Ductless split air conditioning units are the very best thing for some situations. Of course they can be installed in the place of most any central air conditioning unit. They also are a very good alternative to window air conditioning units. I will explore the use of these units more closely and look at how they can be used effectively.
One of the many problems encountered by the professional is when they are asked to install central air conditioning in an older home that was never designed with air conditioning as even a possibility. The walls may be very thick stone. Often they have very little or no insulation. The floor structures may be rough cut lumber. The joists spacing may be random. Walls and ceilings are plaster and lathe. Basically everything is stacked against any type of ducted central air conditioning. Many log style homes also are not very easy to get any kind of ducted central air conditioning installed. The open ceilings and the bare log wall design does not allow for any kind of ducting. I'm sure there are other situations. These are the ones that I have come across most frequently.
If you have a home or building that falls into one of these categories you may want to investigate installing a ductless air conditioner. This type of air conditioner can be installed in almost any home or building. The small indoor unit can be attached to the wall with a few screws. Most of the units only require that a three inch hole be bored through the outside wall. In new installations the units can be placed on inside walls with some fore thought and planning. For installation in older homes or homes that are already built you will want to plan the units to be on the outside walls.
The outdoor condenser units can be placed up to one hundred feet away from the indoor units. One outdoor unit can be used for many indoor units. Up to four indoor units can be attached to the same outdoor condenser. Some very advanced electronics will control the operation of the condenser and compressor to supply the refrigerant to the indoor air handler units that are running at the time. With variable speed technology the compressor and the condenser fan will only run as fast as needed. This technology has become very efficient in the last few years. You do not have to give up any efficiency with these ductless split units.
Another advantage to these mini split air conditioners is that they can be controlled to run only in the rooms that you actually need air conditioning in. If you are not going to be in a room you can shut down the unit. The units also have timers that can be set to turn the air conditioning on or off at preset times. If you are not going to be home all day the air conditioning can be setback or turned off. The timer will turn on the air conditioning so that you return to a cool house. Central air conditioning is very hard to zone effectively. Also with large central air conditioning systems the outdoor compressor will be running at full capacity even though only a few rooms amy be calling for cooling. There are some central air conditioning systems that are do some staging and variable speed technology. These are not as efficient or as effective as the ductless split technology.
Ductless split heatpumps are another great idea to look at. For a few dollars more you can also very easily have heat from your air conditioning mini split. Then especially in the mild spring and fall weather you can have some very efficient heat with out starting up that big monster of a furnace or boiler in the basement. In southern climates the heatpump version of the ductless split system may provide enough heat year around.
Ductless split air conditioning is definitely something that can solve many problems for some homeowners. Add to that the many advantages of these units and you will find that they are worth every penny that you will invest into them. As with any project like this make sure that you screen your contractor. These units are not for do it yourself people. There are many things that need to be done correctly for these units to work properly and efficiently. A refrigeration license is also required to install these air conditioners.
By doing a little research and hiring the right person you will enjoy many years of trouble free service from your new ductless mini split system.

on Dec 04, 2009 | Heating & Cooling

1 Answer

3 split units run from one compressor one is not cooling


If there is 3 indoor units from one condensing unit
(6 pipes at outdoor unit) this is classed as a multi unit

All units will run correctly as long as they all require same mode, cooling or heating, if one unit decides to heat it will shut down until master unit decides to heat then it will start, for each unit to individually heat and cool there would have to be 3 pipes to each indoor,

Dec 19, 2015 | Fujitsu 9RLS 9000 BTU Split System Air...

1 Answer

The unit either encountered a brown out or a surge which burned up the board for the condenser. It had black marks on the board and the indoor unit was flashing. Replaced the board and the unit is still...


After replacing the burned condenser board, check also the entire condensing unit if still ok ( compressor and fan motor). If the light inside the indoor unit is still flashing, the timer is still not giving signal for the compressor to start. Adjust temperature and wait for 3-5 minutes. It light continue flashing, there is something wrong with the indoor unit control.

Sep 02, 2011 | Sanyo Split System Air Conditioner

1 Answer

E 7


Multi Splits and Multi V = indoor unit is set to run in a different mode from the master indoor unit. Set ALL indoor units to cooling or ALL to heating to clear.
Splits = Compressor Over Current (CT2), Check loose wiring/condenser coil for clean

Jan 10, 2011 | AmcorAire UCHW-H24AF2 Split System Air...

3 Answers

Aircon runs for a few minutes then shuts down and timer light flashes


when we start the AC indoor working and out door unit compressor working but fan motor not working and indoor timer light blinking

Dec 16, 2010 | Mitsubishi MSZ-A24NA Split System Air...

1 Answer

LG Art Cool, 2 splits. Error code CH7


Multi Splits and Multi V = indoor unit is set to run in a different mode from the master indoor unit. Set ALL indoor units to cooling or ALL to heating to clear.
Splits = Compressor Over Current (CT2)

Jul 09, 2010 | LG Art Cool LA121CNP wall/window Air...

1 Answer

When we turn on our split AC, outside unit is not turning ON


The blinking light is because the unit is waiting for the outdoor unit to come on. If in heating mode, the indoor fan will not run before enough pressure and therefore heat has built up. You should check that the indoor air return sensor is not faulty and therefore preventing the outdoor unit from coming on.

Nov 15, 2009 | Amcor NanoMax A12000E Portable Air...

1 Answer

Fujitsu Air Conditioning split unit Model


Your compressor is seized up. shut down unit and let compressor cool down, it may start again but probably needs to be replaced.... sorry for the bad news,

Nov 10, 2009 | Fujitsu 24C1 Air Conditioner

1 Answer

Outdoor unit does not start. indoor unit fan does run.


by the sound of it the relay in the outdoor section is bad

May 31, 2009 | Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

132 people viewed this question

Ask a Question

Usually answered in minutes!