You can try to reset the C0500 error code press the soft initialization on the right side of control panel
when the dot appears on the lcd after reboot press the number 3 key the mode will change to the initialization screen choose the selection for trouble reset after reboot the code will be cleared
power on and of for basic screen if this dose not work you will need to replace the fuser unit
in regards to your c0f32 code the toner to carrier ratio is wrong this is caused by the wrong developer being used clean out developer unit and put correct developer in the unit