Tricity Bendix AW1000W Front Load Washer Logo
A
Anonymous Posted on Jan 21, 2011

Colins, Please, I have already checked: the volmetric with PTC door interlock, motor, electrovalves for water fill system, pressure switch, the drain pum, heating element, heating sensor, all the components they are walking well individualy . Nown on the main electronic PCB, The EWM1000 well controls the LEDs on the board but after few minutes the drain pum is activated after the door has been locked. No other program. the concerning LED of each program indicates well the state of each program. I have gather all the good conditions, but only the drain pum can be activated by the main electronic PCB. I have on the Bard: the EWM 1000 for control panel and washing programs, 24C64W6 for EEPROM, 74HC595 8 bits shift register, 74HC4051 multiplexer/demultiplexer analogue, 03 ACS1025T, please where can be the problem, I beg you, I don't want to lost my TRICITY BENDIX washing machine It is useful for me when I Come back home . I work in OFFSHORE for electronic and instrumentationI am a Frenchspeaking. Help me.

1 Answer

Gerry Harvey

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Genius:

An expert who has answered 1,000 questions.

  • Tricity Bendix Master 1,482 Answers
  • Posted on Jan 29, 2011
Gerry Harvey
Tricity Bendix Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Genius:

An expert who has answered 1,000 questions.

Joined: Sep 27, 2009
Answers
1482
Questions
0
Helped
379097
Points
4533

Ok..Not sure if this applies to your model however.The drain pump can be activated by a Float micoswitch if the machine is leaking water, also if the drain hose is too low then it will syphon away the water......Both of these will cause the drain pump to empty the machine..

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

HOTPOINT 9526 DOOR STAY LOCKED AFTER FINISHED THE CYCLE

The first thing to check is - does the washing machine still have water inside? If there is obviously still water inside the machine then this is possibly the cause of the door not opening. Drain the machine.

Can't see any water inside

If you can't see any water inside then it may be caused by various faults listed below. Here's a list of the most common causes of a jammed door -
  1. On some machines if the pressure switch doesn't reset to empty it keeps the door lock energized. If this is the case though, unplugging it should allow the door lock to cool down and open after a few minutes.
  2. The water hasn't pumped out properly (or a blockage in the pressure system is holding the pressure switch on) - but only if the washing machine has a pneumatic (air operated) door safety lock (a rubber hose connected to the door interlock and connected to a pressure chamber bottle on the tub - water forces air up this tube and locks the door)
  3. The water has pumped out properly, but the pressure switch hasn't reset due to a faulty pressure switch or blockage in the pressure system - or the water hasn't pumped out properly and the pressure switch hasn't reset because of the water inside. A faulty pressure switch, or blockage of debris inside the pressure chamber bottle could also be trapping the air that's operating the door lock (if a pneumatic lock is fitted - not many have these days).
  4. The door interlock has just jammed
  5. The door catch, handle, or some part of the door catch mechanism is broken and not opening the door
  6. ****** (a device that detects the motion of the drive belt fitted to many older Hotpoint washing machines which "pecks" at the belt when the door handle or button is operated) is broken or has fallen off
Opening a jammed door Do not take the lid off and reach inside the washing machine to try and release the door if the washing machine is still plugged in as you will be electrocuted.
The most common cause of a jammed door is likely to be a faulty door interlock. Sometimes you can release the door from the inside by manipulating the door interlock or forcing the door catch out from it. But they sometimes just have to be broken away from the machine. If you need to do this make sure you -
  1. Unplug it
  2. Break the interlock off from inside the machine, don't force the door or you will just break more parts
0helpful
3answers

Hotpoint Ultima WF860T

Alarm
code Description of fault User
code Effect
E11 Problems with water fill in wash phase E10 Cycle PAUSED 8.2
E12 Problems with water fill in drying E10 Cycle PAUSED 8.3
E21 Problems with water drain in wash phase E20 Cycle PAUSED 8.4
E22 Problems with water drain during drying or drying
condenser blocked E20 Heating phase skipped 8.5
E31 Analogic (electronic) pressure switch circuit faulty --- Cycle blocked
with door closed 8.6
E32 Incorrect calibration of analogic (electronic) pressure
switch --- Cycle PAUSED 8.7
E33
Incongruency between level of analogic (electronic)
pressure switch and level of anti-boiling pressure
switch 1
--- Cycle blocked
with door closed 8.8
E34 Incongruency between level of electronic pressure
switch and level of anti-boiling pressure switch 2 --- Cycle blocked
with door closed 8.9
E35 Water level too high --- Cycle blocked with door
closed and water drain 8.10
E36 "Sensing" circuit of anti-boiling pressure switch 1 faulty --- Cycle blocked
with door closed 8.11
E37 "Sensing" circuit of anti-boiling pressure switch 2 faulty --- Cycle blocked
with door closed 8.11
E38 Pressure chamber blocked --- Heating phase skipped 8.12
E41 Door open E40 Cycle PAUSED 8.13-14
E42 Problems with door closure E40 Cycle PAUSED 8.15-16
E43 TRIAC which powers the door interlock faulty E40 Cycle PAUSED 8.17-18
E44 "Sensing" circuit of door delay interlock faulty --- Cycle blocked 8.19
E45 "Sensing" circuit of door delay interlock triac faulty --- Cycle blocked
with door closed 8.19
E51 TRIAC which powers the motor short-circuited --- Cycle blocked with door
closed (after 5 attempts) 8.20
E52 No signal from tachometric generator --- Cycle blocked with door
closed (after 5 attempts) 8.21-22
E53 "Sensing" circuit of motor TRIAC faulty --- Cycle blocked
with door closed 8.23
E54 Relays (motor) contacts faulty --- Cycle blocked with door
closed (after 5 attempts) 8.23
E61 Insufficient heating during washing --- Heating phase skipped 8.24
E62 Overheating during washing --- Drain, end of cycle 8.25
E63 Insufficient heating during drying Heating phase skipped 8.26
E64 Overheating during drying --- Heating phase skipped 8.27
E66 Power relay to heating element faulty --- Drain, end of cycle 8.28
E71 NTC wash sensor faulty --- Heating phase skipped 8.29
E72 NTC sensor on drying condenser faulty --- Heating phase skipped 8.30
E73 NTC sensor on drying duct faulty --- Heating phase skipped 8.31
E84 "Sensing" circuit on circulation pump triac faulty --- Drain, end of cycle
(door open) 8.32
E85 Circulation pump faulty --- Drain, end of cycle
(door open) 8.33
E91 Communications error between main PCB and user
interface --- --- 8.34
E93 Configuration error E90 Cycle blocked 8.34
E94 Incorrect configuration of washing cycle E90 Cycle blocked 8.34
EF1 Drain filter blocked LED-EF0 --- 8.35
EF2 Excessive detergent LED-EF0 --- 8.35
Regards David Marsh
tip

Frigidaire Affinity Common Error Codes. (E4A, E9E, E56, E46 and more)

Hi.

This error codes apply to Frigidaire Affinity washers and dryers:

E11 - Fill time too long.

E13 - Water leak in tub, or air leak in air bell.

E14 - Reed switch.

E21 - Water not pumping out fast enough.

E23 - Drain pump relay on control board failed.

E24 - Drain pump relay on control board failed.

E31 - Pressure sensor not communicating with control board.

E35 - Pressure sensor indicates water overfill.

E41 - Control board indicates door switch is open.

E42 - Door remains locked after cycle is completed.

E43 - Control board problem

E44 - Control board problem.

E45 - Control board problem.

E46 - Control board problem.

E47 - Control board is sensing the door PTC circuit is open during spin.

E48 - Control board is sensing the door PTC circuit is closed.

E4A - Program Timeout Fault.

E52 - Bad signal from tacho generator.

E55 - Motor overheating.

E56 - High motor current.

E57 - High current on inverter.

E58 - High current on motor phase.

E59 - No tacho signal for 3 seconds.

E5A - High temperature on heat sink.

E5B - High temperature on heat sink.

E5C - High temperature on heat sink.

E5D - Communication problem.

E5E - Communication problem.

E5F - Communication problem.

E67 - Input voltage on microprocessor incorrect.

E75 - Water temperature sensor circuit (digital readout models only).

E76 - NTC temperature for the cold water valve over the limits

E95 - Communication error.

E9E -Voltage error.

EB1 - Incoming power frequency out of limits.

EB2 - incoming line voltage above 130 VAC.

EB3 - Incoming line voltage below 90 VAC.

EF1 - Clogged drain pump.

EF2 - Too much soap.
0helpful
1answer

Loc error code Frigidaire frontloader

From the frigidaire site.

Error code - Fault condition

E11 Fill time too long.
E13 Water leak in tub or air leak in air bell.
E14 Reed switch.
E21 Water not pumping out fast enough.
E23 Drain pump relay on control board failed.
E24 Drain pump relay on control board failed.
E31 Better models. Pressure sensor not communicating with control board.
E35 Better models. Pressure sensor indicates water overfill.
E41 Control board thinks the door switch is open.
E42 Door remains locked after cycle is completed.
E43 Control board problem.
E44 Control board problem.
E45 Control board problem.
E46 Control board problem.
E47 Board thinks the door PTC circuit is open in spin.
E48 Board thinks the door PTC circuit is closed.
E52 Bad signal from tacho generator.
E55 Motor overheating.
E56 High motor current.
E57 High current on inverter.
E58 High current on motor phase.
E59 No tacho signal for 3 seconds.
E5A High temperature on heat sink.
E5B High temperature on heat sink.
E5C High temperature on heat sink.
E5D Communication problem.
E5E Communication problem.
E5F Communication problem.
E67 Input voltage on microprocessor incorrect.
E75 Better models only. Water temperature sensor circuit.
E76 Better model only. NTC temperature for the cold water valve over the limits.
E95 Communication error.
EB1 Incoming power frequency out of limits.
EB2 Incoming line voltage above 130 VAC.
EB3 Incoming line voltage below 90 VAC.
EF1 Clogged drain pump.
EF2 Too much soap.
0helpful
1answer

Water fill sensor

If the water flows though the inlet then the flow pressure should be good, if not the inlet valve is bad or there is dirt in the filter. Also check the flow at the inlet of the water line. Once the water comes into the system the WATER LEVEL SENSOR - normally a pressure switch- must activate at the preset/chosen level to give the signal to the program controller to switch on the motor. What is most important for the motor to start functioning is that the door switch must be ON when the door is shut or this will be an error for starting the motor for rinse and wash.
Test a pressure switch: Click on : http://www.youtube.com/watch?v=HZZ2bDMspj8

4helpful
2answers

What does e 62 error code refer to?

E62: Overheating during washing this is real ans now iam giving u more tips abt error -
E11: Difficulty in filling during wash phase
E13: Water leakage.
E21: Difficulties in draining .
E23: Malfunction of drain pump triac.
E24: «sensing» circuit of the component (triac) that controls the drain pump faulty
E33: Incongruence between closure of anti-boiling and 1st level contacts of pressure switch
E35: Water level too high
E36: «sensing» circuit of anti-boiling pressure switch faulty
E37: «sensing» circuit of 1st level pressure switch faulty
E39: "HV" «sensing» circuit of anti-overflow pressure switch faulty
E40: Door open, Interlock, wiring or main PCB
E41: Door open
E41: Problems with aperture of door
E42: Problems with aperture of the door
E42: Problems with aperture of the door
E43: Problems with the triac which actions the door interlock
E43: Problems with the triac which actions the door interlock
E44: Door closure «sensing» circuit faulty
E45: Problems with the «sensing» circuit of the triac that actions the door interlock
E51: Motor power triac short-circuited
E52: No signal from the motor tachymetric genetaror
E52: No signal from the tachymetric generator
Procedure for checking commutator motors
E53: Problems with the «sensing» circuit of the triac which powers the motor
E54: Motor relay contacts sticking
E61: Insufficient heating during washing
E62: Overheating during washing
E66: The contacts of the heating element power relay are always closed
E71: NTC washing sensor faulty.
E82: Error in reading the RESET/OFF position of the programme selector.
E83: Error in reading the programme selector code
E93: Incorrect machine configuration.
E94: Incorrect configuration of washing cycle
E95: Communications error between microprocessor and the EEPROM
E96: Incongruence between control panel version and configuration data
E97: Incongruence between selector version and configuration data
EA1: Drum positioning system (DSP) faulty (top-loaders only)
EB1: Incorrect mains frequency
EB2: Mains voltage too high
EB3: Mains voltage too low

E32 INCORRECT CALIBRATION OF ANALOGIC (ELECTRONIC) PRESSURE SWITCH. IF THE MACHINE IS DRAINING OK, THEN IT IS THE SWITCH
E32 relates to the electronic pressure switch, normal pressure switch,inlet valves,poor water mains pressure and finally the main control board
E90 means theres a fault on the main control module so A;will need a new control module or B; get an engineer to try re-configureing the module
8helpful
1answer

Machine keeps stopping and showing fo5

ALARM CODES

E11 Problems with water fill in wash phase E10 Cycle PAUSED 8.2
E12 Problems with water fill in drying E10 Cycle PAUSED 8.3
E21 Problems with water drain in wash phase E20 Cycle PAUSED 8.4
E22 Problems with water drain during drying or drying
condenser blocked E20 Heating phase skipped 8.5
E31 Analogic (electronic) pressure switch circuit faulty --- Cycle blocked
with door closed 8.6
E32 Incorrect calibration of analogic (electronic) pressure
switch --- Cycle PAUSED 8.7
E33
Incongruency between level of analogic (electronic)
pressure switch and level of anti-boiling pressure
switch 1
--- Cycle blocked
with door closed 8.8
E34 Incongruency between level of electronic pressure
switch and level of anti-boiling pressure switch 2 --- Cycle blocked
with door closed 8.9
E35 Water level too high --- Cycle blocked with door
closed and water drain 8.10
E36 "Sensing" circuit of anti-boiling pressure switch 1 faulty --- Cycle blocked
with door closed 8.11
E37 "Sensing" circuit of anti-boiling pressure switch 2 faulty --- Cycle blocked
with door closed 8.11
E38 Pressure chamber blocked --- Heating phase skipped 8.12
E41 Door open E40 Cycle PAUSED 8.13-14
E42 Problems with door closure E40 Cycle PAUSED 8.15-16
E43 TRIAC which powers the door interlock faulty E40 Cycle PAUSED 8.17-18
E44 "Sensing" circuit of door delay interlock faulty --- Cycle blocked 8.19
E45 "Sensing" circuit of door delay interlock triac faulty --- Cycle blocked
with door closed 8.19
E51 TRIAC which powers the motor short-circuited --- Cycle blocked with door
closed (after 5 attempts) 8.20
E52 No signal from tachometric generator --- Cycle blocked with door
closed (after 5 attempts) 8.21-22
E53 "Sensing" circuit of motor TRIAC faulty --- Cycle blocked
with door closed 8.23
E54 Relays (motor) contacts faulty --- Cycle blocked with door
closed (after 5 attempts) 8.23
E61 Insufficient heating during washing --- Heating phase skipped 8.24
E62 Overheating during washing --- Drain, end of cycle 8.25
E63 Insufficient heating during drying Heating phase skipped 8.26
E64 Overheating during drying --- Heating phase skipped 8.27
E66 Power relay to heating element faulty --- Drain, end of cycle 8.28
E71 NTC wash sensor faulty --- Heating phase skipped 8.29
E72 NTC sensor on drying condenser faulty --- Heating phase skipped 8.30
E73 NTC sensor on drying duct faulty --- Heating phase skipped 8.31
E84 "Sensing" circuit on circulation pump triac faulty --- Drain, end of cycle
(door open) 8.32
E85 Circulation pump faulty --- Drain, end of cycle
(door open) 8.33
E91 Communications error between main PCB and user
interface --- --- 8.34
E93 Configuration error E90 Cycle blocked 8.34
E94 Incorrect configuration of washing cycle E90 Cycle blocked 8.34
EF1 Drain filter blocked LED-EF0 --- 8.35
EF2 Excessive detergent LED-EF0 --- 8.35
Regards David Marsh
4helpful
2answers

Washing machine keeps stopping mid wash and coming up error (32 motor surrisc) zanussi keeps stopping and reporting E32 as a fault, how do i fix this?

Hello
ALARM CODES

E11 Problems with water fill in wash phase E10 Cycle PAUSED 8.2
E12 Problems with water fill in drying E10 Cycle PAUSED 8.3
E21 Problems with water drain in wash phase E20 Cycle PAUSED 8.4
E22 Problems with water drain during drying or drying
condenser blocked E20 Heating phase skipped 8.5
E31 Analogic (electronic) pressure switch circuit faulty --- Cycle blocked
with door closed 8.6
E32 Incorrect calibration of analogic (electronic) pressure
switch --- Cycle PAUSED 8.7
E33
Incongruency between level of analogic (electronic)
pressure switch and level of anti-boiling pressure
switch 1
--- Cycle blocked
with door closed 8.8
E34 Incongruency between level of electronic pressure
switch and level of anti-boiling pressure switch 2 --- Cycle blocked
with door closed 8.9
E35 Water level too high --- Cycle blocked with door
closed and water drain 8.10
E36 "Sensing" circuit of anti-boiling pressure switch 1 faulty --- Cycle blocked
with door closed 8.11
E37 "Sensing" circuit of anti-boiling pressure switch 2 faulty --- Cycle blocked
with door closed 8.11
E38 Pressure chamber blocked --- Heating phase skipped 8.12
E41 Door open E40 Cycle PAUSED 8.13-14
E42 Problems with door closure E40 Cycle PAUSED 8.15-16
E43 TRIAC which powers the door interlock faulty E40 Cycle PAUSED 8.17-18
E44 "Sensing" circuit of door delay interlock faulty --- Cycle blocked 8.19
E45 "Sensing" circuit of door delay interlock triac faulty --- Cycle blocked
with door closed 8.19
E51 TRIAC which powers the motor short-circuited --- Cycle blocked with door
closed (after 5 attempts) 8.20
E52 No signal from tachometric generator --- Cycle blocked with door
closed (after 5 attempts) 8.21-22
E53 "Sensing" circuit of motor TRIAC faulty --- Cycle blocked
with door closed 8.23
E54 Relays (motor) contacts faulty --- Cycle blocked with door
closed (after 5 attempts) 8.23
E61 Insufficient heating during washing --- Heating phase skipped 8.24
E62 Overheating during washing --- Drain, end of cycle 8.25
E63 Insufficient heating during drying Heating phase skipped 8.26
E64 Overheating during drying --- Heating phase skipped 8.27
E66 Power relay to heating element faulty --- Drain, end of cycle 8.28
E71 NTC wash sensor faulty --- Heating phase skipped 8.29
E72 NTC sensor on drying condenser faulty --- Heating phase skipped 8.30
E73 NTC sensor on drying duct faulty --- Heating phase skipped 8.31
E84 "Sensing" circuit on circulation pump triac faulty --- Drain, end of cycle
(door open) 8.32
E85 Circulation pump faulty --- Drain, end of cycle
(door open) 8.33
E91 Communications error between main PCB and user
interface --- --- 8.34
E93 Configuration error E90 Cycle blocked 8.34
E94 Incorrect configuration of washing cycle E90 Cycle blocked 8.34
EF1 Drain filter blocked LED-EF0 --- 8.35
EF2 Excessive detergent LED-EF0 --- 8.35
Regards David Marsh
2helpful
1answer

Washing Machine starts, squirts water, then stops.

E5E  IS FOR  Communication problem. THERE IS 100 %WIRE SHORTING SOMEWHERE.PLEASE CHECK OUT.
ALSO OTHER ERRORS Error code - Fault condition
E11 Fill time too long.
E13 Water leak in tub or air leak in air bell.
E14 Reed switch.
E21 Water not pumping out fast enough.
E23 Drain pump relay on control board failed.
E24 Drain pump relay on control board failed.
E31 Better models. Pressure sensor not communicating with control board.
E35 Better models. Pressure sensor indicates water overfill.
E41 Control board thinks the door switch is open.
E42 Door remains locked after cycle is completed.
E43 Control board problem. 
E44 Control board problem. 
E45 Control board problem. 
E46 Control board problem.
E47 Board thinks the door PTC circuit is open in spin.
E48 Board thinks the door PTC circuit is closed.
E52 Bad signal from tacho generator.
E55 Motor overheating.
E56 High motor current.
E57 High current on inverter.
E58 High current on motor phase.
E59 No tacho signal for 3 seconds.
E5A High temperature on heat sink.
E5B High temperature on heat sink.
E5C High temperature on heat sink.
E5D Communication problem.
E5E Communication problem.
E5F Communication problem.
E67 Input voltage on microprocessor incorrect.
E75 Better models only. Water temperature sensor circuit.
E76 Better model only. NTC temperature for the cold water valve over the limits.
E95 Communication error.
EB1 Incoming power frequency out of limits.
EB2 Incoming line voltage above 130 VAC.
EB3 Incoming line voltage below 90 VAC.
EF1 Clogged drain pump.
EF2 To much soap.

8helpful
2answers

Error codes

Hello ALARM CODES Alarm code Description of fault User code Effect E11 Problems with water fill in wash phase E10 Cycle PAUSED 8.2 E12 Problems with water fill in drying E10 Cycle PAUSED 8.3 E21 Problems with water drain in wash phase E20 Cycle PAUSED 8.4 E22 Problems with water drain during drying or drying condenser blocked E20 Heating phase skipped 8.5 E31 Analogic (electronic) pressure switch circuit faulty --- Cycle blocked with door closed 8.6 E32 Incorrect calibration of analogic (electronic) pressure switch --- Cycle PAUSED 8.7 E33 Incongruency between level of analogic (electronic) pressure switch and level of anti-boiling pressure switch 1 --- Cycle blocked with door closed 8.8 E34 Incongruency between level of electronic pressure switch and level of anti-boiling pressure switch 2 --- Cycle blocked with door closed 8.9 E35 Water level too high --- Cycle blocked with door closed and water drain 8.10 E36 "Sensing" circuit of anti-boiling pressure switch 1 faulty --- Cycle blocked with door closed 8.11 E37 "Sensing" circuit of anti-boiling pressure switch 2 faulty --- Cycle blocked with door closed 8.11 E38 Pressure chamber blocked --- Heating phase skipped 8.12 E41 Door open E40 Cycle PAUSED 8.13-14 E42 Problems with door closure E40 Cycle PAUSED 8.15-16 E43 TRIAC which powers the door interlock faulty E40 Cycle PAUSED 8.17-18 E44 "Sensing" circuit of door delay interlock faulty --- Cycle blocked 8.19 E45 "Sensing" circuit of door delay interlock triac faulty --- Cycle blocked with door closed 8.19 E51 TRIAC which powers the motor short-circuited --- Cycle blocked with door closed (after 5 attempts) 8.20 E52 No signal from tachometric generator --- Cycle blocked with door closed (after 5 attempts) 8.21-22 E53 "Sensing" circuit of motor TRIAC faulty --- Cycle blocked with door closed 8.23 E54 Relays (motor) contacts faulty --- Cycle blocked with door closed (after 5 attempts) 8.23 E61 Insufficient heating during washing --- Heating phase skipped 8.24 E62 Overheating during washing --- Drain, end of cycle 8.25 E63 Insufficient heating during drying Heating phase skipped 8.26 E64 Overheating during drying --- Heating phase skipped 8.27 E66 Power relay to heating element faulty --- Drain, end of cycle 8.28 E71 NTC wash sensor faulty --- Heating phase skipped 8.29 E72 NTC sensor on drying condenser faulty --- Heating phase skipped 8.30 E73 NTC sensor on drying duct faulty --- Heating phase skipped 8.31 E84 "Sensing" circuit on circulation pump triac faulty --- Drain, end of cycle (door open) 8.32 E85 Circulation pump faulty --- Drain, end of cycle (door open) 8.33 E91 Communications error between main PCB and user interface --- --- 8.34 E93 Configuration error E90 Cycle blocked 8.34 E94 Incorrect configuration of washing cycle E90 Cycle blocked 8.34 EF1 Drain filter blocked LED-EF0 --- 8.35 EF2 Excessive detergent LED-EF0 --- 8.35 Regards David Marsh
Not finding what you are looking for?

181 views

Ask a Question

Usually answered in minutes!

Top Tricity Bendix Washing Machines Experts

Paul Bade

Level 3 Expert

1818 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66931 Answers

Are you a Tricity Bendix Washing Machine Expert? Answer questions, earn points and help others