Help.My Arctic Air Freezer F22CWF is not cooling. Freezer is brand new but was in storage for 4 yrs. Everything turns on, Fan, light, compressor under. but does not cool at all. Thanks

Posted by on

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Expert
  • 1,772 Answers

Sorry to read about your problem. you can have many different problems.
I think you have lost freon, but you could have the problems below.

1. Bad temp control
2. Defective compressor
3. Defective start cap
4. Defective overload protector
5. Defective control board

I suggest you call a service company.

I have tried to help you. Please help me, by Vote/Rate my response. Thanks.

If you live in the Denver area, I can help you.

4 Thumbs - Very Helpful
3 Thumbs - Helpful
2 Thumbs - Somewhat Helpful
1 Thumb - Not Helpful

Posted on Jan 04, 2011

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
New users get 2 Free calls (no credit card required) and instant help on almost anything you can think of (from cars to computers, appliances, handyman, and even pets).
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Parts for door storage


Try a company called e spares on the internet

Jan 01, 2014 | Arctic Air 22 cu. ft. Commercial Freezer...

1 Answer

Freezer off


Check to see if the compressor is hot

Nov 27, 2013 | Arctic Air 22 cu. ft. Commercial Freezer...

1 Answer

My new compressor is noisy


Sure it's the compressor, not a condenser fan hitting on something disturbed when you had the new compressor fitted? If it is the compressor, get the fitter to replace it under warranty.

May 08, 2012 | Arctic Air 22 cu. ft. Commercial Freezer...

1 Answer

I have arctic air commercial freezer m # F2CW11 s/n# WB338336 freon R134a what psig ? low side and high side when system on


Good day,
When running, the low side is usually about 2 to 4 lbs pressure. The high side is determined by the load and the temperature in the room or area. Minimum 125 lbs. maximum approx. 150 lbs.

Oct 28, 2010 | Arctic Air 22 cu. ft. Commercial Freezer...

1 Answer

Artic air not freezing! Help!


dear sir/madam

please make sue your freezer.s compressor it,s working or not if compressor is working then there is low gas problem then please contact to your service technician for refill gas .

hope answer the question

please vote
thank you!

Sep 01, 2010 | Arctic Air 22 cu. ft. Commercial Freezer...

1 Answer

The temp only goes down to 30 farenheit. the thermostat control knob is set to the coldest position. is the thermostat faulty or can it be adjusted?


Check list:
Fans running
Compressor cool to the touch
Not short cycling (low freon)
coils cleaned
no air restrictions
If all of that is good bypass the control
see if it gets down to 0
If it does replace the control

May 25, 2010 | Arctic Air 22 cu. ft. Commercial Freezer...

1 Answer

F22cw thaws & compressor is very hot..will stay that way for a day or 2 then starts working again...also fan on bottom of unit net to compressor doesn't seem to work.....help


Your problem is probably attributed to one of the following:

* compressor
* attachments to compressor (e.g.: relay, capacitor (if applicable) and overload protector)
* refrigerant restriction or leak

Contact an appliance service company.

Feb 19, 2010 | Arctic Air 22 cu. ft. Commercial Freezer...

1 Answer

Have a arctic air f22cwf freezer that will not freeze right


There is a starter relay on the compressor. It sounds like it needs replacing. If you listen for awhile when it trys to start the compressor there will be a clicking sound but then nothing will happen. That is the most likely cause.

May 05, 2009 | Arctic Air 22 cu. ft. Commercial Freezer...

Not finding what you are looking for?
Arctic Air 22 cu. ft. Commercial Freezer F22CWF Logo

Related Topics:

459 people viewed this question

Ask a Question

Usually answered in minutes!

Top Arctic Air Freezers Experts

Dennis Boxerman

Level 3 Expert

1150 Answers

Charles T Nevin
Charles T Nevin

Level 3 Expert

4066 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Are you an Arctic Air Freezer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...