Anonymous Posted on Jan 03, 2011

Condensate pump does not pump. Pump runs but no output. Bucket full light comes on.

2 Answers

Dan Webster

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Frigidaire Master 8,221 Answers
  • Posted on Jan 03, 2011
Dan Webster
Frigidaire Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Dec 14, 2008
Answers
8221
Questions
5
Helped
2380603
Points
25840

Might be something blocking the pump or hose. Or the hose could have come off the pump or the bucket aint sitting in its position so that the switch is engaged.

If you need further help, reach me via phone at https://www.6ya.com/expert/dan_73bbd84fe1d95b61

Dana Newcombe

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

  • Master 1,564 Answers
  • Posted on Jan 03, 2011
Dana Newcombe
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

Joined: Jun 20, 2009
Answers
1564
Questions
3
Helped
540363
Points
4667

If you would please, tell me how old is this unit?

  • 1 more comment 
  • Anonymous Jan 03, 2011

    Been in use for roughly a year. Cools an IT equipment room.
    Pumps condensate to adjacent drain.

  • Dana Newcombe
    Dana Newcombe Jan 03, 2011

    I'm sorry, but I have to ask if there is indeed any water in the tank when you get the light, and if so, how much? Considering the age of the unit it probably is not a mechanical fault as much as it could be an electronic fault.

  • Dana Newcombe
    Dana Newcombe Jan 03, 2011

    Does this unit have a mechanical pump to send the waste water out or is it just a gravity feed?

×

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

John Deere 3350 hydraulics pressure problem

https://www.pembinatrails.ca › ...PDF
Web results
OPERATOR'S MANUAL
1helpful
2answers

Condensate pump runs but does not pump

I have only seen a couple but they were pressed on the shaft. Superglue might work.
0helpful
1answer

We installed a new condensation pump about a year ago and it has worked fine up until now. It still seems to be working but when we run our central a/c unit for more than a few hours water collects...

There must be a hole in the condensate pan if it's not coming from over the top. Bleach only prevents mold and bacteria growth, not blockages. Check and clean the drainage tubing connected to the condensate pump
2helpful
2answers

What does bucket full mean on my frigidaire portable air conditioner mean

this type of unit has a condensate drain bucket that holds the condensation that is removed from the air, this bucket needs to emptied when the light comes on.
0helpful
1answer

I have a Hotpoint CTD00 Condensing tumble dryer. The pump which takes the condensate to the reservoir seems to be running continually and not relying on the float switch. I assume the pump should only...

No, the float switch activates when the storage tank is full. To confirm this lift the float and you will see the "Empty Water" light come on at the front of the machine.
0helpful
1answer

Red bucket full light stays on.

If the bucket is full then the pump should be running, if the pump is not running it is a faulty pump motor, a faulty control board, a faulty level switch for the pump motor or the water level alarm float switch.
1helpful
1answer

'bucket full' light on, but bucket empty

There is likely a switch operated by a float to turn that light on and turn off the compressor, sometimes manufactures use a rubber "O" ring on the float shaft and they can slip. take the cover off the pump and check the float or in some cases one of two floats are used. Once float turns the pump on and off and the second float shuts OFF the compressor and turns ON the full reservior light.
1helpful
1answer

Little Giant Condensate pump runs for 1 sec when res not full

Is there a check valve in the pumps discharge fitting? If there is it may be stuck open or broken allowing some of the water to return to the reservoir once the pump shuts off which then may lead to the brief cycle between full cycles.

If there is not one, install one to keep any water from backing back into the reservoir and that should stop the short runs.
Aug 06, 2009 • Plumbing
0helpful
1answer

Empty bucket light is on and dehumidifier will not run

The float switch for the condensate reservoir (bucket) is malfunctioning.

It's sending a false signal that the bucket is full.

Maybe just stuck and needs cleaning or it may have failed.
0helpful
1answer

I wish to purchase DDR606 dehumidifier. Will need to place a pump into bucket to send water up basement wall and out thru window. Will this work with this model? Thanx!

This will work for all models. You just need to get a condensate pump. Hook drain from dehumidifier to the condensate pump. the dehumidifier will need to be higher than the pump so it can drain.
Not finding what you are looking for?

149 views

Ask a Question

Usually answered in minutes!

Top Frigidaire Heating & Cooling Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Brad Brown

Level 3 Expert

19187 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a Frigidaire Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...