Question about Garden

1 Answer

I purchased a masterbuilt electric smoker from a local retail store model 20070810 and it has been great until the other day i went to turn it on and nothing it has not been moved or anything since the first use and havent had any issues until now any ideas?

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 2,299 Answers

Without looking at the smoker it is hard to tell exactly what is wrong. I would suggest checking continuity on the heating elements. This is a good place to start. You should have continuity. If you don't and the element is open, then you will need to replace the element. If it is not open, then check for power at the element when the smoker is turned on. If no power then check the switch that turns it on. Make sure that you are getting power from the switch.

Posted on Jan 03, 2011

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

The Masterbilt 20070106 which we bought 18 months ago is "dead". There is power coming from the electrical outlet, but there is no power to the smoker. I do not see a website for parts for the...


You are not the first Masterbuilt Electric Smoker owner to have this problem. The Model 20070106 has been plagued with electrical problems from day one. Maybe, that's why it only has a 90 day warranty?

As far as parts are concerned, you can call Masterbuilt (800-489-1581), first to see if they can help you. More than likely, you will need to replace the electronic control panel on the top of the smoker and maybe the electric element, too.

Another place to try is www.factoryapplianceparts.com.

Sep 20, 2011 | Masterbuilt 20070106 Electric Smoker

1 Answer

I need an element for Mod: 20070106 Ser.# GA040925


You can purchase a new heating element part # 990050051 either from Masterbuilt or from Factory Appliance Parts http://www.appliancefactoryparts.com/gasgrillparts/brands/masterbuilt/
If they are still available. All of Masterbuilt's electric smokers have been plagued with electrical problems.. It's either the element or the electronic controller on the top of the smoker, that constantly fail.

Hope this helped you and thanks for choosing FixYa.

Sep 20, 2011 | Masterbuilt 20070106 Electric Smoker

1 Answer

My smoker does not smoke at 220 degrees it did fine in colder weather


Either the heating element or the controller on top of the smoker has failed. This is a chronic problem with Masterbuilt electric smokers. That's probably the reason it on has a 90 day warranty.

You can purchase the part(s) from Masterbuilt or from Factory Appliance Parts
http://www.appliancefactoryparts.com/search/partinfo.php?partsID=491507&modelsID=135884&typeName=gas%20grill

Hope this helps you & thanks for choosing FixYa.

Sep 11, 2011 | Masterbuilt 20070106 Electric Smoker

1 Answer

I have a Masterbuilt electric smoker and have lost the instructions that came with it. Would instructions from a different smoker work with my Masterbuilt? Do you know how I might get the Masterbuilt...


Masterbuilt makes several different models of electric smokers. f you can furnish the correct model number of yours, I may can help you.

Thanks for choosing FixYa.

Aug 05, 2011 | Grilling

1 Answer

Need copy of users manual


Here's a link to the Owners Manual, which is listed for your electric smoker from Masterbuilt.

http://www.masterbuilt.com/pdf/manuals/07092010%2020070910%20Manual.pdf

You can download and print it. Hope this helps to get you started. If it di, please be kind enough to rate my response to you. Thanks and have a great day!

Mar 25, 2011 | Masterbuilt 20070106 Electric Smoker

1 Answer

Smoker was working great. Went to smoke some ribs this morning and my controller won't go above 90. Help!


Your heating element is now probably inop. You'll have to go onto masterbuilt.com and order another element. Try this site:
http://www.masterbuilt.com/pm-smokers.html

Feb 26, 2011 | Masterbuilt 20070106 Electric Smoker

1 Answer

I purchased a masterbuilt smoker in Jan/2010 Model E 20070910. First time I used it had no problem with generating smoke but ever since I can not generate smoke I've tried pellets & even Hickory...


Try this...

I just bought a new Masterbuilt Smoker by default two weeks ago I borrowed a friend’s to smoke about 30lb. of Salmon to then can. Ran the smoker every day for three day. ON my last batch the heating element would not work. Talk about Frustrated! The Smoker was only 2 yrs. old.

Knowing I borrowed I felt I had to replace. So online to Cabelas and I ordered my buddy a new smoker and had it shipped. I then found this website... GOT TO LOVE the internet. I saw many other people had the same problem. Found an Answer...

The Problem was one of the connector to the heating element was poor quality and if you don't clean your smoker on a regular basis. The heat and moister caused the small copper connector to corrode and the wire to come loose. I took a wood chisel and cut off all the rivets on the back. I was then able to pull the back off with no damage and access the small box in the lower back. I found the connector. Went to the hardware store and bought a replacement for .75 cents. A pair of wire crimpers and the problem was fixed. I also bought ½ inch Sheet metal screws to secure the back it was good as new. So I returned the smoker to my buddy and kept the new one. When it arrived I saw Masterbuilt has since fixed the problem and provided an access panel to the element and connectors.

Mike in Alaska

PSU313@yahoo.com

Jun 17, 2010 | Masterbuilt 20070106 Electric Smoker

1 Answer

More receipes


Try this link. http://www.masterbuilt.com/recipes.html

Also try to Google "smokering". There are some great smoker sites on the web.

Hope this helps.

May 29, 2010 | Masterbuilt 20070106 Electric Smoker

1 Answer

Used the masterbuilt smoker only 5 times???


I just bought a new Masterbuilt Smoker by default two weeks ago I borrowed a friend’s to smoke about 30lb. of Salmon to then can. Ran the smoker every day for three day. ON my last batch the heating element would not work. Talk about Frustrated! The Smoker was only 2 yrs. old.

Knowing I borrowed I felt I had to replace. So online to Cabelas and I ordered my buddy a new smoker and had it shipped. I then found this website... GOT TO LOVE the internet. I saw many other people had the same problem. Found an Answer...

The Problem was one of the connector to the heating element was poor quality and if you don't clean your smoker on a regular basis. The heat and moister caused the small copper connector to corrode and the wire to come loose. I took a wood chisel and cut off all the rivets on the back. I was then able to pull the back off with no damage and access the small box in the lower back. I found the connector. Went to the hardware store and bought a replacement for .75 cents. A pair of wire crimpers and the problem was fixed. I also bought ½ inch Sheet metal screws to secure the back it was good as new. So I returned the smoker to my buddy and kept the new one. When it arrived I saw Masterbuilt has since fixed the problem and provided an access panel to the element and connectors.

Mike in Alaska

PSU313@yahoo.com

Jun 20, 2009 | Masterbuilt 20070106 Electric Smoker

1 Answer

Masterbuilt Smoker Model 20070108 Digitial Controller not working. Worked the first time, then no power. I hear a beep when I plug it in, but no display.


I had the same problem this morning. I seasoned it two days agao with an outside temp. of 50. This morning it was 8 degrees and when I pluged it in there was no readout. I removed the digital unit from the top and heated it with a hair drier and it worked when I reinstalled it. I think it had some moisture in it although the unit has been covered the whole time. I am going to call Masterbuilt tomarrow and see what their answer is to this problem.

Jan 17, 2009 | Masterbuilt 20070106 Electric Smoker

Not finding what you are looking for?
Garden Logo

Related Topics:

45 people viewed this question

Ask a Question

Usually answered in minutes!

Top Garden Experts

Dennis Key
Dennis Key

Level 3 Expert

2475 Answers

john h

Level 3 Expert

11064 Answers

yadayada
yadayada

Level 3 Expert

75077 Answers

Are you a Garden Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...