Question about All-Pro Kerosene Garage Shop Heaters - All Pro PK115T Forced Air Kerosene Space Heater

1 Answer

I have a all pro R60A that turns on but shuts right off and blows tons of smoke out after shutting off.

Posted by on

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    Novelist:

    An expert who has written 50 answers of more than 400 characters.

    Champion:

    An expert who has answered 200 questions.

  • Expert
  • 224 Answers

These heaters have several things that happen to them while in storage. I do a yearly check on mine and it goes like this. Open the fuel tank and tilt the heater to see fuel at the filler hole, look at the fuel and tank you are looking for any water in the tank. Condensation is usually the culprit, what I do is drain the tank in to a clean five gallon bucket and the fuel floats on top of the water. If you see water use a rag and try to dry out the tank as best as you can. You can also siphon off the fuel for reuse just be careful not to siphon to much and get the water again. Next remove the top section of the heater tube, this exposes all of the internal burner parts. Locate the burner tray and remove it so you can access the fuel nozzle. Remove the nozzle, they say you cannot clean these but I say different. You need a Q-tip, tooth pick and carb cleaner and clean it up carefully so you do not damage the nozzle. Behind the nozzle is a screen these like to corrode so clean it real good too. Put the nozzle assembly back together, inspect your fuel lines for cracks, dry rot or holes and replace if necessary. At the bottom of the assembly there is a sensor for flame these collect carbon deposits,dirt and the occasional homeless insect. Clean this with windex and a soft terry cloth rag. Put the burner tray back together. Trace the fuel lines back to where they come thru the heater tube and now remove the side cover. You will find the fuel line and an in line filter remove the filter and clean this with a compressor and blow gun by blowing air backwards thru the filter. This instantly cleans the filter, now put it back together after inspecting the fuel lines,and replacing it if necessary. Put the side cover back on and go to the fuel/ air pump on the back of this there should be an air filter usually foam, clean this with dawn dish soap and dry really good before putting it back in.Inspect and clean igniter while you are inside the heater, then put the top section back together. Now you are ready to plug your heater back in and test it. If all went well you should be heating like it did when it was new. Just a tip for you is to look at the fuel coming out the nozzle it should be a fog not droplets, if droplets your nozzle needs changed. Pay attention to spray angle and GPH rating very very important.

Posted on Dec 29, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
New users get to try the service completely Free afterwhich it costs $6 per call and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Heater runs for 2-3 minutes then shuts off. unplugged to reset and it runs again for less than minute then shuts off again


Clean or replace your photo cell. Make sure your air pressure is set right,Remove your nozzle and blow air thru it . To test your photocell use a muti-meter hooked to two wire and hold flashlight over the end of boot see if ohms increase if not it junk,replace it.

Feb 08, 2011 | Reddy R60A Utility Heater

1 Answer

Shuts down after about 30 seconds, blowing some smoke.


Hi,


Here are a couple of tips that I wrote that tell you how to troubleshoot a Torpedo or Reddy heater...

Reddy Heater - Troubleshooting Torpedo Heaters





Torpedo Heater Pump Pressure Adjustment


heatman101

././././././././././././././././

Nov 27, 2010 | All-Pro Kerosene Garage Shop Heaters - All...

1 Answer

My reddy heater comes on and burns perfectly for up to 30 minutes then it shuts off and blows smoke for a couple of seconds before it completely shuts down.


This doesn't help. There at least 4 60k Reddy Heaters models -some are spark plug heaters, some have the new Hot Surface Ignitor technology. All heaters have specific model. Without you knowing the model I can't help, sorry.

Mar 14, 2010 | Reddy R60A Utility Heater

1 Answer

My ALL-PRO R60A heater light and burns for a


I think you are talking about the igniter,go on line,I think reddy heater parts,type that in.

Oct 17, 2009 | Reddy R60A Utility Heater

1 Answer

Ihave a R60A heater that when I turn it on it


This is in referance to the R60a 60,000 B.T.U. Multi fuel heater
Sounds like the your ignitor has burned out. Had the same problem. Now looking for a replacement. Checked mine and for some reason the filiment has broken/burned off. Ran across this on a search for one. Good luck!

Oct 11, 2009 | Reddy Heater RLP100 Portable Forced Air...

1 Answer

Pro 110, runs 10 min., blows white smoke ,shuts off


the first thing you need to do is go back to useing K1 kerosene, diesel fuel not only burns dirty but also has a tendency to gel up in cold weather which could be makeing it hard for the heater to draw the proper amount of fuel. To reset the pressure you will need a gage, it should run at about 6-7 psi. you can order a pressure gage from mr. heater online, they are by far the cheapest I have found as they are the actual manufacturer or call 1-800-251-0001

Feb 05, 2009 | Reddy Heater-170,000 BTU Kerosene Deluxe

1 Answer

Reddy Heater 50'000 BTU - Puffs Smoke and Leaks Out The End


Hi,
Here are a couple of tips that I wrote that tell you how to troubleshoot aTorpedo or Reddy heater...

Reddy Heater - Troubleshooting Torpedo Heaters Torpedo Heater Pump Pressure Adjustment
heatman101

/...

Jan 30, 2009 | Reddy R60A Utility Heater

1 Answer

Blowing smoke immediately prior to auto-shut-off


Try a new CAD falme sensor, or high limit control, both very cheap.

Jan 07, 2009 | Reddy R155D Utility Heater

1 Answer

All Pro 170t kerosene heater is throwing raw fuel out the burner


It sounds like it is currently working .. is that right? Or does it only work if you let it sit for an hour, still? The blue smoke probably is from the residual fuel not burnt when it "threw raw fuel out the end" some the fuel probably drained to a low point ..outside of the combustion chamber and then may have ignited after shut down.. to cause the blue smoke out the back... when you turned it off.

If when your starting it up... it doesn't start the first time.. wait 10seconds then try again.. noting what it apparently does.. and doesn't do. does it just 'through fuel for 5 seconds.. does the fan spin .. and push air at the same time when its starting? If yes for both, does the ignitor ignite the fuel/air mixture, briefly then it shuts off.. ?? Hope this line of thinking helps you out
md

Dec 31, 2008 | All-Pro Kerosene Garage Shop Heaters - All...

Not finding what you are looking for?
All-Pro Kerosene Garage Shop Heaters - All Pro PK115T Forced Air Kerosene Space Heater Logo

183 people viewed this question

Ask a Question

Usually answered in minutes!

Top All-Pro Heating & Cooling Experts

Paul Carew

Level 3 Expert

2550 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

T bone 1963

Level 2 Expert

67 Answers

Are you an All-Pro Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides