Hi, I have a Bosch WR250 tankless gas instant water heater. My problem is i am not getting a spark at the pilot when the hot water is turned on,the red light flashes after 10sec. I can here the (water/spark)generator turning but i get nothing. I have checked all electrical connections and they seem fine, any suggestions please?

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

Flashing red light indicates not enough pressure on the input cold water. I had this problem when the small filter was gummed up with ****. Remove the water input nut and inside is a small removable mesh filter. Also the hydro power unit that you hear whirring has a even finer mesh filter. It can also be cleaned out.

Posted on Jun 27, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have a bosch aquasar 125b tankless water heater and the burners do not light when hot water is turned on this also causes the pilot light to go out


possible faulty pressure switch connected to the water line and that is failing to turn on the main gas tap solenoid
best have it checked by an accredited gas fitter or service center for the make

Aug 20, 2016 | Bosch AquaStar Indoor Natural Gas Tankless...

1 Answer

I have a Bosch 10P water heater. Pilot light has blown out and while trying to relight the pilot the stop button has been pushed down and won't pop back out. What am i doing wrong? Cheers


What leads you to suspect that pilot blew out instead of another problem?
Fact that pilot will not relight, indicates other factors at play.

Open following link for Bosch troubleshooting resources including manual, and Bosch contact info:
http://waterheatertimer.org/Troubleshoot-Bosch-Tankless-water-heater.html

Best place to start is your manual.
http://waterheatertimer.org/pdf/Bosch_10P-installation.pdf

1) Manual recommends 'cleaning by authorized person, never less than once a year.'
Tankless water heaters, and most newer tank-type gas water heaters, are highly technical and finicky devices that require continual maintenance, with tankless requiring 'yearly' maintenance while tank-type require 'periodic' maintenance.
2) Troubleshoot in manual says 'no gas supply' or 'blocked pilot' replace pilot injector

Upvote the help.
And take advantage of fixya expert assistance live.
For a price, expert works with you while you work on water heater or any do-it-yourself project.
Fixya is always less expensive than a service call.

May 21, 2011 | Bosch & Tankless LP Hot Water Heater

1 Answer

I have a Bosch Water Wizard 10P - have no hot water, no water comes out the hot water tap, can't light Pilot Light, not sure where to start would love a step by step diagram how to start pilot light -...


Open following link for Bosch tankless troubleshooting resources, including Bosch contact information, typical manuals, error codes, tech support, parts, fuel-saver calculator, service bulletins, water heater forum, fixya links, disclaimers, and links for finding service technician.
http://waterheatertimer.org/Troubleshoot-Bosch-Tankless-water-heater.html

Before calling service technician, read manual for fault finding and possible solutions.
Read manual cover to cover, make sure tankless receives yearly maintenance as outline in manual.
http://waterheatertimer.org/pdf/Bosch_water-wizard.pdf
http://waterheatertimer.org/pdf/Bosch_13P_16P_In.pdf

Following links talk about keeping pilot lit, and describe location somewhat. Bosch water wizard has standing pilot light.
http://www.fixya.com/support/t2961646-water_wizard_10p_pilot_light_keeps_going
http://www.fixya.com/support/t2960079-bosh_water_wizard_10p_pilot_light_keeps
http://www.fixya.com/support/t6182021-bosch_10p_tankless_hot_water

1) The manual does not show diagrams you asked for.

2) Website that sells Bosch parts does not show parts for water wizard, nor does Bosch site for parts: Instruction manual says: replace pilot injector
http://www.boschhotwater.com/HelpfulResources/PurchaseParts/tabid/837/Default.aspx
http://www.houseneeds.com/shop/heatingproducts/waterheating/parts/bosch2400espartsbuy.asp#

3) Searching "pilot injector for Bosch Water wizard" turns up fixya questions which is generally bad news for do-it-yourselfer because it means information sources are through service technician.

4) As a general rule, tankless are not do-it-yourself repairs or installation because they are affected by so many internal and external factors, including air quality, air flow, venting, other gas appliances, gas pressure, gas supply, water pressure, water flow, plumbing problems, water quality, plus internal parts and including any combination of things listed above..
Replacement parts each come will disclaimer.

Add a comment with your experience so others with same-similar problem can benefit.
Send some photos so the internet can see the problem.
http://www.fixya.com/support/r6568559-post_photograph_fixya_questions_answers

Also take advantage of fixya expert assistance live.
For a price, expert works with you while you work on water heater or any do-it-yourself project.
Fixya is always less expensive than a service call.

Apr 03, 2011 | Bosch & Tankless LP Hot Water Heater

1 Answer

I have a Bosch 125 BNG gas tankless water heater. Pilot light will not light but spark is there. Solution and where do I get parts assuming needed.


Check and be sure gas knob is in the pilot lighting position and pushed in. Try to manually light with a match. Make sure gas **** is in the on position. Posible air in the gas line. Bled off air. gas valve or regulator has failed..

Jan 04, 2011 | Bosch AquaStar Indoor Natural Gas Tankless...

1 Answer

Bosch AquaStar tankless natural gas water heater pilot goes out periodically--after a few hours or a few days, whether weather hot or cold, whether windy or not. This condition has been the same from day...


I had a similar problem with mine and it turned out to be a plugged air vent sceen. This is the small dome like sceen on the gas valve. I vaccumed out the unit and have not had the pilot go out in over a year.

Nov 27, 2010 | Bosch AquaStar Indoor Natural Gas Tankless...

1 Answer

I have a Bosch GWH 425 HN Tankless Hot Water Heater...On 2/28/2010, it began intermittant exploding when demand for hot water occurred. Local technicians worked on the unit several times, changed and...


I have the same problem with the same model. The problem has been identified by a friend of mine, correctly, I think.
This is a very dangerous problem involving Bosch's much touted safety feature, ironically enough. IT IS THE FLAME SENSOR IN THE GAS VALVE. The flame sensor is supposed to confirm that the pilot has lighted BEFORE the main gas line sends gas to the main burners, after which the pilot shuts off. The pilot light is not coming on, the sensor that shouldn't let gas fto the main burners is failing and the main gas is flowing and ignighting from the spark that is supposed to light only the pilot in a big explosion.
This is the 2nd unit of this model that has failed. I think Bosch should do a recall

Apr 25, 2010 | Bosch & Tankless LP Hot Water Heater

1 Answer

No hot water, pilot light lights but no burner ignition


Thermo coupler may be defective. it controls the main gas valve by closing main if pilot is out. make sure thermo coupler bulb is positioned over and near tip of pilot flame, but not in the flame. Thermo couplers are inexpensive and easy to change out.

May 05, 2009 | Bosch & Tankless LP Hot Water Heater

1 Answer

Bosch tankless GWH 1600 H NG won't always ignite. The igniter sparks, but doesn't always light the gas. It just clicks. When installed it lit every time, now it takes more and more tries to get it to...


The manual says to hold a match near the pilot while the ignitor is trying. It says that if the unit lights the pilot orifice may be dirty or clogged. Then the manual says to check the voltage on the igniter. It should be 1.3 volts DC minimum if it is not means the electronic control box is defective.

Let me know the status ...Kevin

Mar 29, 2009 | Bosch 1600H-NG Natural Gas AquaStar...

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

194 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2046 Answers

Dan Webster
Dan Webster

Level 3 Expert

8205 Answers

Cris Sparks
Cris Sparks

Level 2 Expert

338 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...