Question about Carrier Heating & Cooling

1 Answer

I have a carrier Puron unit that is six years old. We had to replace the compresor on the third year, and now it is three years later and the second unit has failed.

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    Novelist:

    An expert who has written 50 answers of more than 400 characters.

    Champion:

    An expert who has answered 200 questions.

  • Expert
  • 230 Answers

I have seen this before when there is an obstruction in the evaporator coil metering device. This causes the compressor to struggle moving the Puron. After the Puron has been recovered make sure that they do a complete check of the metering device and check for other obstructions. When they are done checking they must do a proper vacuum to remove any non condensables like water condensation. Finally they should have installed both a liquid and suction filter dryer to reduce any dirt and stuff. The only other options are unlikely, as we will assume that the last company installed the correct (new) compressor and that they did not do a hack job.

On a happier note, the compressor should still be under the 10 year parts warranty!

Posted on Jul 01, 2008

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Bad condenser unit GOODMAN


it is a 3 ton condensor you still can buy r22 freon condensors new but they have nitrogen charge and its expensive to charge I recommend to go with 3 ton goodman condensor which is new 410a puron and also change indoor coil and flush the line set so you dont endure the high cost of new copper lines these new systems come with 10 years warranty and the r22 systems come with only five years

Feb 26, 2013 | Heating & Cooling

2 Answers

I replaced my whole heat pump system 3 years ago with a Carrier Puron unit. The installer called me this week and told me that I needed to replace the puron after the third year at a approx cost of...


Tell him you already had it done. lol. Unless you misunderstood what he told you no! You don't need to replace the Refrigerant weather it's Puron or Freon. It doesn't wear out. Ever. If your system develops a leak and you loose the Refrigerant it will have to be replaced but you will know you lost it because the system won't cool and heat like it's supposed to. I would report the installer to the better business bureau.

Aug 31, 2010 | Carrier Heating & Cooling

1 Answer

We have recently had three problems with our three year old Carrier 24 ACA airconditioner that I believe has led to it no longer producing the low temp. chilled air it did when it was installed. !. water...


Your air temp should be at least 20 degrees cooler than the indoor air temp. This is ideal. But it sound like your unit is low on freon. When units get low they will freeze up. They will also freeze up if air flow is restricted on the inside coil or the fan quits on the external unit.

Aug 08, 2010 | Carrier 38CKC024 Air Conditioner

1 Answer

1994 Carrier 58 PAV


sounds like the relay for the unit may be bad, usually if a blower motor goes it stops or has a very loud humm and only goes slow

Aug 03, 2009 | Heating & Cooling

2 Answers

Compressor fan and compressor not running new 2 yr old system puron


No power to outside unit. Check to see if contactor on outside unit is pulled in. Most AC units inside have float switch. When the drain stops up it shuts off outside unit. Located in overflow or underneath unit. No Problem Rusty

Jun 05, 2009 | Carrier 38CKC036 Air Conditioner

1 Answer

AC will not cool. How much should a service charge cost?


If the upstairs is working and the down stairs is not,You only need to have one unit checked,Don't assume it just needs puron(If it does,You have a leak,which cost more to locate and repair than some other likely causes)This is not something you can do yourself and is illegal if you are not EPA certified.to get a fair price would depend on your geographic location and the best way would be to call around to some local heating and air companies and ask how much a service call is.(That only tells you the price for them to came and see what the problem is,They will not be able to quote a price until they know what must be done to make the repairs.

I hope this has answered all your questions.

Please take time to rate this fixya

May 16, 2009 | Carrier 38CKC036 Air Conditioner

1 Answer

Cost to replace carrier 38ckc060


Did your unit work last summer? 10 Years old is very soon unless it is a cheap unit like janitrol or goodman. Most units last min. 15 years and 20 most of the time. Generally speaking any ways. To replace compressor cost maybe 750.00 to 1,000.00 you have a big house looks like. 5 Ton unit. The whole system could be 6000.00 to 8000.00 depending on grade of unit. I would get a second opinion though cause I am wondering if they are just padding their pocket.

Apr 16, 2009 | Carrier 38CKC060 Air Conditioner

1 Answer

Furnace runs OK, but blower runs again a few seconds later


Could be a defective thermostat in the plenum.
When a gas furnace shuts down the fan(blower) will run until the plenum cools to the safe range. Usually 1 and 1/2 minutes.
Intermittent operation is a defective thermostat or relay.

Mar 11, 2009 | Carrier Heating & Cooling

1 Answer

Amana Air Command 80, 20 years old. Electronic ignition. Furnace does not start. Good power to furnace. Themostat properly set. Where do I start looking? Bob


Hello Bob,
Welcome to fixya,

You said, Amana Air Command 80, 20 years old.
Electronic ignition.
Furnace does not start.
Good power to furnace.
Thermostat properly set.
Where do I start looking?

Sounds like you possibly have one or more bad jets if the unit is a gas furnace!
Let me know how it goes.
Huuum

WOW, listen to this story!
I understand you are looking for the solution to fix your furnace your self.
But I want to tell you my story about my smart wife and our furnace.
When we moved into this house the furnace was 20 years old and she suggested that we put a new one that it will save us money.
I laughed at her and replied if it's not broken why fix it!
Six years later it finally broke down and I replaced the whole furnace and central air unit with a new one.
Our utility bill went down $100 dollars a month!
That's $7200. that I lost over 6 years due to not respecting my wife's power of reasoning!
If you can afford it or can get financing replace any unit 20 years old and it will pay for it self.
Can you imaging $1200. a year for 20 years is $24,000 dollars I'm saving with a new and efficient unit.
Do the math!!!!!!!!!

Thank You,
Huuum, Hope I gave you some good fatherly advice.
Please remember to leave a rating


Oct 12, 2008 | Amana Heating & Cooling

1 Answer

Carrier air conditioner problem


My Carrier unit did the same thing. It was low on refrigerant (Puron in my unit). I am worried I have a leak somewhere. Hopefully, it is not in the coil. The service call wasn't cheap either. Puron runs around $10-15 a pound and mine took several pounds to replenish.

Aug 01, 2008 | Carrier 38CKC036 Air Conditioner

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

531 people viewed this question

Ask a Question

Usually answered in minutes!

Top Carrier Heating & Cooling Experts

Dan Webster
Dan Webster

Level 3 Expert

8205 Answers

Bill Long

Level 3 Expert

587 Answers

Cris Sparks
Cris Sparks

Level 2 Expert

338 Answers

Are you a Carrier Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions