Question about Hoshizaki Commercial Freezer KM-500MAH

2 Answers

Hoshizaki ice machine with constant beeping every 3 seconds

Model number KM 500 MAE is not making ice and this constant beeping noise every 3 seconds

Posted by on

  • 2 more comments 
  • eevader Sep 14, 2008

    Yeah i have the same problem . beeping noises every three seconds and when pressing ice machine black push button. no ice will come out?? please notify me e-mail at eevader@aol.com. thank you

  • Anonymous Oct 10, 2008

    comes on for about 3 seconds and go off and a beeping gos off and on and machine will not come on.

  • Anonymous Oct 10, 2008

    machine comes on and then it will start peeping

  • HoshizakiIce.com
    HoshizakiIce.com Feb 01, 2012

    As part of the EverCheck System, the beeps are to help diagnose problems with the machines. Built-in safeties shut down the unit and have alarms as listed below:

    Number of Beeps Every 3 Seconds Type of Alarm and Notes
    1 Beep High Evaporator Temp. (temp > 127*F/ 53*C)
    Check for harvest problem (stuck HGV or relay), hot water entering
    unit, stuck HM, or shorted thermistor.
    2 Beeps Harvest Backup Timer (harvest>20 min, 2 cycles in a row)
    Check for open thermistor, HGV not opening, TXV or LLV leaking by,
    low charge, inefficient compressor, or WRV leaking by.
    3 Beeps Freeze Timer (freeze > freeze timer setting for two cycles in a row)
    Check if float switch stuck closed (up), WB leaking by, HGV leaking by,
    PM not pumping, TXV not feeding properly, LLV not opening, low
    charge, HM not bypassing, or inefficient compressor.
    To reset the safeties above, press the "ALARM RESET" BUTTON
    WITH THE POWER SUPPLY ON.
    6 Beeps Low Voltage Red LED turns off if voltage protection operates. The control voltage
    7 Beeps High Voltage safeties automatically reset when voltage is corrected.
    At startup, a 5 second-delay occurs while the control board conducts an internal timer check. A beep occurs when the control switch is moved to the "ICE" position. www.hoshizakiice.com

×

2 Answers

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Director Badge:

    Uploaded 100 video answers.

  • Hoshizaki Master
  • 460 Answers

Most likely(50% of the times) Your Ice machine need a real cleaning. not just run clean cycle with ice machine cleaner. every 6 month call HVAC-R guys - machine will last half time longer if u schedule proper maintenance with them. I have seen It all: people try to call "friend", or someone who "knows" how this machines work. Real clean would take up to 3 hours for people who know what they doing. Here is one of my videos, when 3 beeps - long freeze cycle is not common and all others would offer You to get a new Ice Machine. Bill to the owner was 950$, New Machine 3450$ plus labour to install 600$.

Posted on Nov 06, 2015

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Guru:

    An expert who has written 7 tips or uploaded 3 video tips

  • Master
  • 462 Answers

I believe if you remove the thermostat wires and put them together and retry it you'll be making Ice, then get you a new thermostat. Please rate me accordingly and good luck.

Posted on Mar 20, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

My hoshizaki ice machine KM-900mrf model beeps 3 times and stop making ice. After reset it starts, but stats beeping again after an hour.


Have a look at the side of the evaporator; there is a probe (thermistor) attached to it that tells the control board when to initiate the harvest cycle. make sure it's clean and attached properly and doesn't need replacing. If hitting the float switch initiates the harvest cycle it sounds like you have a blocked/ scaled water tube or switch housing. take off the bottom of the switch assembly (black rubber bit) and clean through to the water chamber. run a cycle of descaler before trying again.

Jul 04, 2015 | Hoshizaki Freezer Commercial Ice Machines...

1 Answer

Hoshizaki Model KM 630 MAE


Look for a stuck float switch. unit fills with water for 1 minute, then the board "looks" at the float to "see" if there is enough water in the unit to run. If float switch is stuck down, it tells the unit there is not enough water and the unit stays in the fill cycle causing the sump to overflow and send water down the drain constantly. Compressor will not run till the board senses that there is enough water to run.

Jun 25, 2012 | Hoshizaki Freezer Commercial Ice Machines...

1 Answer

I have a Hoshizaki model Km-250baf it beeps three times.


3 beeps means it has been in the freeze cycle too long. A stuck float switch can cause this as well as a leaking water valve. Look for that first. Let me know if you need more info.

Feb 06, 2011 | Hoshizaki Freezer Commercial Ice Machines...

2 Answers

KM-500-MAE Hoshizaki Problem huge cubes, alarm code three beeps


Might need to clean float switch, or water inlet valve bypassing water. Deep clean Hoshizaki.

Sep 30, 2010 | Hoshizaki Commercial Freezer KM-500MAH

1 Answer

KM-500-MAE Problem huge cubes,alarm code 3-beeps


excessive freeze cycle=60 minutes. In almost every case, it's the water valve (sometimes called the fill valve) is leaking water continually into the sump. Turn machine off and see if you can still hear water running into the unit. If so, it the valve leaking. Just replace it.
http://www.hoshizakiamerica.com/manuals/KM-500M_E_serv.pdf
Go to this site and download you copy of the service manual. It has lots of good stuff.. Let me know if I can be of any further help.

Sep 30, 2010 | Hoshizaki Freezer Commercial Ice Machines...

1 Answer

3 beeps every two seconds not making ice


http://www.hoshizakiamerica.com/techsupport/faq-km.asp#11

Aug 12, 2010 | Hoshizaki Freezer Commercial Ice Machines...

1 Answer

Hoshizaki ice machine with constant beeping every 2 seconds


turn it off and on and check the drain line and see if its draining water. some times the check valve needs taken apart and cleaned. the problems corespond to water related problems. usually because its taking too long to freeze. good luck

Dec 27, 2008 | Hoshizaki Commercial Freezer KM-500MAH

1 Answer

Km 500 kae hoshizaki 3 beeps every 4 second compressor not coming on


put an amp probe on common wire at compressor and see what amps are when it tries to start. 40 to 60 is mechancially locked up compressor. kill power and test start and run capacitors. there is an thermal temp over load on the compressor that opens when comp gets hot from trying to start. gently remove and look for cracks or burned looking. . i saw one this week doing exact same and i have ordered the oem compressor start cap realy and run cap and drier and will put in all new gas. be sure to allow sufficient time when switched to ice for it to get to ref cycle, it may take 5 minutes starting with water purge, then fill, etc. good luck, call hoshizaki dist they are usually pretty helpful if you need a auth service rep in you area. i think they are three years warrantied!

Oct 25, 2008 | Hoshizaki Freezers

1 Answer

Hoshizaki ice machine model KM-250BAF SERVICE MANUAL


km-450mwb hoshizaki problem is machine strate is ok but to long time ice making , not dropping, two beeps every three seconds what problem i don't no pleas help mi

Jul 30, 2008 | Hoshizaki Freezer Commercial Ice Machines...

5 Answers

Beeping Ice Machine


I have a Hoshizaki KM-250BAF that is making 3 beeps then pauses and them makes 3 beeps again. If I unplug the ice maker and plug it in it continues to make the 3 beeps. The manual does not mention anything about beeps. Can anyone help?

Jul 09, 2008 | Hoshizaki Freezer Commercial Ice Machines...

Not finding what you are looking for?
Hoshizaki Commercial Freezer KM-500MAH Logo

2,786 people viewed this question

Ask a Question

Usually answered in minutes!

Top Hoshizaki Freezers Experts

Dan Webster
Dan Webster

Level 3 Expert

8205 Answers

yadayada
yadayada

Level 3 Expert

64034 Answers

John Tripp
John Tripp

Level 3 Expert

4638 Answers

Are you a Hoshizaki Freezer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides