Question about Air Conditioners

1 Answer

I HAVE A BELLING TOUCH TRONIC 4 RING HOBB. THERE IS POWER TO THE UNIT BUT WHEN I PRESS THE ON BUTTON IT WONT COME ON.

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    Novelist:

    An expert who has written 50 answers of more than 400 characters.

    Champion:

    An expert who has answered 200 questions.

  • Expert
  • 230 Answers

I am not too familiar with this unit. However, I would look for any on board fuses or surge protectors. If it still fails to come on then I believe this to be a blown circuit board.

Posted on Jun 23, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My 2hp Panasonic is blinking when turn on and the compressor stop working while the outdoor fan will be blowing cool air.


1. Turn power on.
2. Press the CHECK button on the remote controller
continuously for 5 seconds.
3. "- -" will be displayed on the remote controller display.
Note: Display only for "- -". (No transmitting signal, no
receiving sound and no Power LED blinking.)
4. Press the "TIMER" or button on the remote
controller. The code "H00" (no abnormality) will be
displayed and signal will be transmitted to the main
unit. The power LED lights up. If no abnormality is
stored in the memory, three beeps sound will be
heard.
5. Every press of the button (up or down) will increase
abnormality numbers and transmit abnormality code
signal to the main unit.
6. When the latest abnormality code on the main unit
and code transmitted from the remote controller are
matched, power LED will light up for 30 seconds and
a beep sound (continuously for 4 seconds) will be
heard. If no codes are matched, power LED will light
up for 0.5 seconds and no sound will be heard.

Jan 26, 2016 | Panasonic Air Conditioners

1 Answer

Drain water light is blinking unit wont power on


Make sure the unit is on a flat, level surface. If the floor is not level or the carpeting is too thick, the unit will not be level, causing the water in the internal tray to flow to one side. This will bypass the water full safety mechanism and the unit will not automatically shut off.

Check for broken or damaged casters. Check to make sure the casters are installed securely and evenly.

Check and make sure the drain cap and/or the rubber plug is installed. If cap or rubber plug is missing, use a cork. Check and see if the drain is cracked or broken, if so, shave broken drain flat and use a cork. You can use a plumbing adhesive or epoxy to repair the drain.
And regarding that the unit is not powering on i would suggest you with the following things.
Test the outlet that the PAC is plugged into is working. If the outlet is working than the powerplug breaker needs to be replaced. If the wall outlet is not working, there may be too many appliances on one circuit. Recommended circuit is 20amps. You can also administer a power plug check: Power Plug Check
1. Press the RESET button. The reset button may be stubborn so you will need to press HARD to reset it until a click is heard and the light comes on.
2. Insert the power plug into the electrical outlet.
3. Press the TEST button. If the circuit breaker is working you'll hear a click.
4. Press the RESET button until you hear another click. The circuit breaker in the plug is now activated.
5. Do not use the air conditioner if the above procedure cannot be successfully performed.
After switching the air conditioner off, wait 3 minutes before switching it back

Jul 18, 2015 | Air Conditioners

1 Answer

Panasonic beat pump


Possibly, check error codes for problems:
• To make a diagnosis
1. Timer LED start to blink and the unit automatically stops the operation.
2. Press the CHECK button on the remote controller continuously for 5 seconds.
3. "- -" will be displayed on the remote controller display. Note: Display only for "- -". (No transmitting signal, no receiving sound and no Power LED blinking.)
4. Press the "TIMER" or button on the remote controller. The code "H00" (no abnormality) will be displayed and signal will be transmitted to the main unit.
5. Every press of the button (up or down) will increase abnormality numbers and transmit abnormality code signal to the main unit.
6. When the latest abnormality code on the main unit and code transmitted from the remote controller are matched, power LED will light up for 30 seconds and a beep sound (continuously for 4 seconds) will be heard. If no codes are matched, power LED will light up for 0.5 seconds and no sound will be heard.
7. The breakdown diagnosis mode will be canceled by pressing the CHECK button continuously for 5 seconds or without any operation the remote control for 30 seconds.
8. The LED will be off if the unit is turned off or the RESET button on the main unit is pressed.

May 31, 2015 | Panasonic Air Conditioners

1 Answer

My Panasonic split air conditioner has stopped cooling - model:CU-W18DKR. The internal unit and internal fan operate normally. The external unit fan does not run like normal and no compressor sounds f


Sounds like a faulty outdoor controller board. If you are in Australia, call Prime Electronics or Statewide Appliances for spares.
Part number: NPCWA743383

• To make a diagnosis
1. Timer LED start to blink and the unit automatically stops the operation.
2. Press the CHECK button on the remote controller continuously for 5 seconds.
3. "- -" will be displayed on the remote controller display.
Note: Display only for "- -". (No transmitting signal, no
receiving sound and no Power LED blinking.)
4. Press the "TIMER" or button on the remote controller. The code "H00" (no abnormality) will be displayed and signal will be transmitted to the main unit.
5. Every press of the button (up or down) will increase abnormality numbers and transmit abnormality code signal to the main unit.
6. When the latest abnormality code on the main unit and code transmitted from the remote controller are matched, power LED will light up for 30 seconds and a beep sound (continuously for 4 seconds) will be heard. If no codes are matched, power LED will light up for 0.5 seconds and no sound will be heard.
7. The breakdown diagnosis mode will be canceled by pressing the CHECK button continuously for 5 seconds or without any operation the remote control for 30 seconds.
8. The LED will be off if the unit is turned off or the RESET button on the main unit is pressed.

Or better yet, get a tech to check first.

Feb 10, 2015 | Panasonic Single Split System - Wall...

1 Answer

Hi my panasonic CS-PS18NKQ is not working,timer indicator keep on blinking.


• To make a diagnosis
1. Timer LED start to blink and the unit automatically stops the operation.
2. Press the CHECK button on the remote controller continuously for 5 seconds.
3. "- -" will be displayed on the remote controller display. Note: Display only for "- -". (No transmitting signal, no receiving sound and no Power LED blinking.)
4. Press the "TIMER" or button on the remote controller. The code "H00" (no abnormality) will be displayed and signal will be transmitted to the main unit.
5. Every press of the button (up or down) will increase abnormality numbers and transmit abnormality code signal to the main unit.
6. When the latest abnormality code on the main unit and code transmitted from the remote controller are matched, power LED will light up for 30 seconds and a beep sound (continuously for 4 seconds) will be heard. If no codes are matched, power LED will light up for 0.5 seconds and no sound will be heard.
7. The breakdown diagnosis mode will be canceled by pressing the CHECK button continuously for 5 seconds or without any operation the remote control for 30 seconds.
8. The LED will be off if the unit is turned off or the
RESET button on the main unit is pressed.

When you have the error code, you can narrow down the problem.

Feb 04, 2015 | Panasonic Air Conditioners

1 Answer

Hi I have a panasonic split air conditioner. It turns itself off immediately after turning on, the timer button then flashes and that's all.... I have checked for an error code it is H00. I have also made...


Hi Tania,
Have you gone through this checking sequence.? it's from a Panasonic a/c manual. It could be something as simple as a clogged filter. Once you have rectified the fault, you will probably have to clear the fault code as described at bottom below, before it will condescend to work again.
David
  • Once error occurred during operation, the unit will stop its operation, and Timer LED blinks.
  • Although Timer LED goes off when power supply is turned off, if the unit is operated under a breakdown condition, the LED will ON again.
  • In operation after breakdown repair, the Timer LED will not blink. The last error code (abnormality) will be stored
    in IC memory.
14.2.2 To Make a Diagnosis

  1. 1 Timer LED starts to blink and the unit automatically stops the operation.
  2. 2 Press the CHECK button on the remote control continuously for 5 seconds.
  3. 3 "- -" will be displayed on the remote control display.
    Note: Display only for "- -" (No signal transmission, no receiving sound and no Power LED blinking)
  4. 4 Press the TIMER ? or ? button on the remote control. The code "H00" (no abnormality) will be displayed and signal will be transmit to the main unit.
  5. 5 Each press of the button (? or ?) will increase error code number and transmit error code signal to the main unit.
  6. 6 When the latest abnormality code on the main unit and code
    transmitted from the remote control are matched, Power LED will
    light up for 30 seconds and a "beep" sound (continuously for 4
    seconds) will be heard. If no codes are matched, Power LED will light up for 0.5 seconds and no sound will be heard.
  7. 7 The breakdown diagnosis mode will be canceled unless pressing the CHECK button continuously for 5 seconds or operating the unit for 30 seconds.
  8. 8 The LED will be off if the unit is turned off or the RESET button on the main unit is pressed.
14.2.3 To Display Memorized Error Code (Protective Operation)
  1. 1 Turn power on.
  2. 2 Press the CHECK button on the remote control
  3. 3 "- -" will be displayed on the remote control display. Note: Display only for "- -" (No signal transmission, no receiving sound and no Power LED blinking)
  4. 4 Press the TIMER ? or ? button on the remote control. The code "H00" (no abnormality) will be displayed
    and signal will be transmit to the main unit.
  5. 5 Each press of the button (? or ?) will increase error code number and transmit error code signal to the main
    unit.
  6. 6 When the latest abnormality code on the main unit and code transmitted from the remote control are matched,
    Power LED will light up for 30 seconds and a "beep" sound (continuously for 4 seconds) will be heard. If no
    codes are matched, Power LED will light up for 0.5 seconds and no sound will be heard.
  7. 7 The breakdown diagnosis mode will be canceled unless pressing the CHECK button continuously for 5
    seconds or operating the unit for 30 seconds.
  8. 8 The same diagnosis can be repeated by turning power on again.
14.2.4 To Clear Memorized Error Code after Repair (Protective Operation)

  1. 1 Turn power on (in standby condition).
  2. 2 Press the AUTO button for 5 seconds (a "beep" sound is heard) on the main unit to operate the unit at Forced Cooling Operation Mode.
  3. 3 Press the CHECK button on the remote control for about 1 second with a pointed object to transmit signal to
    main unit. A "beep" sound is heard, and the Error Code is cleared

Dec 10, 2014 | Panasonic Air Conditioners

1 Answer

I HAVE A FEDDERS AIR CONDITIONER MODEL AED24E7F-C THIS UNIT TRIPS THE RESET BUTTON ONCE IN A GREAT WHILE IT RUNS FOR HOURS OR DAYS ON END AND THEN TRIPS. IT TAKE AWHILE AFTER THAT BEFORE I CAN RESET...


The reset button is part of the cord. The cord has built in arc detection. This is a complex circuit that monitors the unit and senses potentially dangerous sparks or arcing inside the internal components of the A/C (motors, switches, etc.) It sounds like the problem is getting worse - as they usually do. Sparking and arcing happen when dirt, corrosion, etc. accumulates and can result in pitted contacts. All of these conditions only make the sparks and arcs worse. Page 1 of the manual (left column) says this:

If the Arc Detection Device has tripped, the
reset button will pop up.


Follow these steps to reset the Arc Detection
Device:


1. Unplug unit from electrical outlet
2. Press the reset button
3. Plug the unit back into electrical outlet
4. Check to see if power has returned to the unit

Testing


You should test the Arc Detection Device
equipped power cord monthly, after every major
electrical storm, or if power to your Room Air
Conditioner has been interrupted.

Follow these steps to test the Arc Detection
Device:


1. Unplug unit from electrical outlet
2. Press the reset button
3. Plug the unit back into electrical outlet
4. Press test button. Unit should trip and reset
button will pop up.
5. Press reset button again for use
If above test fails, stop using the air
conditioner and contact customer service by
calling the following toll-free number:
1-800-332-6658 or email:
customerservice@fedders.com

I hope this helps & good luck!

Aug 30, 2011 | Air Conditioners

1 Answer

Cannot turn on.


Since you have power to the clock display- there is power to the unit. The "power" function button has failed because the momentary switch on the circuit board below the touch pad has failed. These little push switches have a short service life.
I suggest checking a source who sells the control circuit board for Soleus Air LX-140. Might be similiar component.
KT

Jul 30, 2010 | Soleus LX-120 Air Conditioner

3 Answers

My unit shut off now displays E1.


Sharp updated the procedure for resetting the E1 code.

1. unplug unit
2. hold the Power button while plugging the unit back in
3. keep holding the Power button until the unit beeps
4. unplug unit again
5. plug it back in and it should be good

Here is the updated user manual

http://www.sharpusa.com/downloads/archives/product_manuals/air_man_AFS100FX_S120FX_S125FX_R100FX_R120FX.pdf

Jun 05, 2010 | Sharp AF-S120FX Air Conditioner

Not finding what you are looking for?
Air Conditioners Logo

Related Topics:

57 people viewed this question

Ask a Question

Usually answered in minutes!

Top Air Conditioners Experts

Dan Webster
Dan Webster

Level 3 Expert

8147 Answers

Bill Long

Level 3 Expert

577 Answers

Tim Whalen

Level 3 Expert

3056 Answers

Are you an Air Conditioner Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...