Question about Maytag Performa PAV2200

1 Answer

Fridge and freezer not cold

Everything in the freezer thawed out and the fridge is not cold. We can hear it running and adjusted the freezer control but nothing happens. the freezer fan is running.

Posted by on

  • 2 more comments 
  • cinderella49 Jun 21, 2008

    Maytag Side by Side Refridgerator-freezer Model PS*21***R*

  • Anonymous Jun 22, 2008

    I have a maytag performa fridge that we bought in 2005. Last year I had the same problems, and it was the relay something, it was a $300 repair. Not even a year later, I have the problem again.

  • fairlycloudy Dec 14, 2008

    Maytag side by side delivered

    Wed.; freezer not working Sat.

  • eric bosman
    eric bosman May 11, 2010

    ? please state brand and model number as you are listing under washers. lol and they are never cold

×

1 Answer

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

It happenedn to my performa fridge just yesterday. It was bought in 2005. Now there is humming and clicking sound from the lower back side once in a while and the fridge is not cold. the compressor is hot/warm and it seems to be where the noise is coming from.

Posted on Jul 04, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

KitchenAid KSSS36FKX00 Dampner frozen. ice cold freezer warm fridge


Fridge freezing up- and no fan or air circulation:


AT TIMES The fan usually stops working due to ice obstruction when the defrost terminator has gone out and u get ice build up? u can check the terminator with a multi meter for continuity but do not check at room temperature. stick the terminator in cup of ice water for 20 minutes then check it for continuity, should be closed when cold and open at room temperature.
May also need to check the defrost timer, The defrost timer is usually found behind the front grill "toe kick" of the refrigerator. Or in the fridge compartment near middle top section.
u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad?
Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next.
Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance..

Another item to check with a meter is the heating element itself. Located under the evaporator coils. It should show continuity or resistance OHMS WHEN TESTED AT BOTH ENDS OF THE PRONGS .

Lastly check the cold control thermostat with a meter for both OHMS and volts ( VOLTS is a live test with fridge plugged in so be careful) It must show 110 volts. An open or thermostat that reads infinity will not allow the proper cooling and defrosting cycles to operate and may in fact stop anything from happening as if there is no power to the unit?

ALSO CHECK THE AIR FLOW VENT SYSTEM and THERMISTORS At times it can get stuck to far closed or open. Some units feature a digital electric adjusting vent system while others are manually set. Check for any ice build up or other obstruction in the vent damper, see if u can manually open or close it. Some times when u have the settings set to the highest it closes off one area while allowing to much cold air flow to the other area!
THERMISTORS in the freezer and fridge section for continuity OHMS and for amount of OHMS current being put out. In most models around 1300 ( give or take 150 ohms) ohms is required


God is so good: so this is why I give free advice so please thank him not me.
















25196408-iizpua1124tc1voeqjalmrl5-3-0.jpg

25196408-iizpua1124tc1voeqjalmrl5-3-2.jpg

25196408-iizpua1124tc1voeqjalmrl5-3-5.jpg

25196408-iizpua1124tc1voeqjalmrl5-3-9.jpg

25196408-iizpua1124tc1voeqjalmrl5-3-14.jpg

25196408-iizpua1124tc1voeqjalmrl5-3-20.jpg

Oct 07, 2014 | KitchenAid KHWS01PWH Global Horizontal...

1 Answer

M y Westinghouse mastermind fridge/freezer just runs and runs , it is cold but hardly ever cuts out


Hay Paul ,
1) Are the door gaskets torn ?
2) Is the fridge empty , in order for the unit to cycle it must replace warm air with cold air .
GOOD LUCK
APPLIANCES R'EN

Dec 11, 2013 | Washing Machines

1 Answer

Freezer cold fridge not found no air flow. took apart and found evap frosted up bad. checked heater with meter and it has continuity. do not want to just start replacing parts. Does it have a timer or...


DEFROST PROBLEM
The evaporator coil behind the cover on the back wall inside the freezer will ice up under normal conditions. Every 8 to 10 hours for around 20 minutes the defrost timer (or in most newer models the electronic adaptive defrost control) will turn the defrost heater on to melt the built up ice. There is a defrost thermostat which prevents the heater from overheating the freezer by breaking the heater circuit when the temp reaches close to 32 degrees F. The entire cooling system shuts off during the defrost cycle and starts back when the timer advances through the cycle.

If this ice is not melted it will continue to build up until the air can't flow over the coil to circulate the cold air through the freezer and into the fridge. The temperature change in the fridge is usually noticed first followed by the freezer.

If the defrost thermostat is bad, it can prevent the heater from coming on OR it won't turn the heater off when it gets too warm. It is clamped to the evaporator coil at the top to sense the temp. If it appears to be misshapen it is bad.
With an ohm meter it should show continuity when cold and none when warm.
You can also bypass(disconnect the two wires plugged into it and twist them together) the thermostat to see if the heater comes on then. If it does then you know the thermostat is bad and needs replaced.

The defrost heater is located on the evaporator. It is in a tube which is at the bottom and can also go up the sides of the evaporator. On some types you can see a burnt spot if it's bad. With an ohm meter it should show continuity from end to end when disconnected from the wiring in the freezer. You can also test the wiring for voltage when it's in the defrost mode.

If you have a defrost timer you can test it. It can be located under the fridge behind the kick panel on the front. Some are in the fridge with the controls at the top. You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer because that means the timer is not running. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.

If you have an adaptive defrost control instead of a timer, replace it if the heater and thermostat test good. It is located in the fridge with the controls in some models and on the back in others.

Mar 22, 2011 | Kenmore Washing Machines

1 Answer

My Maytag MSD2756GE is not cooling on the regrigerator side but is freezing ok. What could be the problem?


Normal 0 MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-fareast-font-family:"Times New Roman";} The fridge gets its cold air from the freezer through a vent(damper) between the freezer and fridge.The fan in the freezer blows air through it. Make sure this fan is running. You may have to hold the door switch in for it to run. There is a flap you adjust with the fridge temp. control. Make sure it's opening and closing when you adjust the fridge temp.
The problem could be the electronic control if you have one or the mechanical linkages.

If the evaporator coils behind the back panel of the freezer are icing up because of auto defrost failure that will stop the circulation of cold air and eventually affect the freezer too.

check defrost timer, defrost heater, defrost thermostat. In most newer models the timer has been replaced by an electronic control board. If the heater and thermostat are ok it’ll be the control.

Dec 13, 2009 | Washing Machines

1 Answer

Kitchenaid Side by Side Refrigerator minus the cold air?


your compressor has issues. some times the start relay goes bad or the compressor windings are shot. thats why it clicks on then off .a service tech can install a "3-n-1 hard start on it. sometimes that works. good luck

Dec 10, 2009 | Washing Machines

1 Answer

Interior frost buildup - about half way down from the top of the refrigerator 10 inces by 20 inches about a quarter inch deep


Normal 0 MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-fareast-font-family:"Times New Roman";} DEFROST PROBLEM
The evaporator coil behind the cover on the back wall inside the freezer will ice up under normal conditions. Every 8 to 10 hours for around 20 minutes the defrost timer (or in most newer models the electronic adaptive defrost control) will turn the defrost heater on to melt the built up ice. There is a defrost thermostat which prevents the heater from overheating the freezer by breaking the heater circuit when the temp reaches close to 32 degrees F. The entire cooling system shuts off during the defrost cycle and starts back when the timer advances through the cycle.

If this ice is not melted it will continue to build up until the air can’t flow over the coil to circulate the cold air through the freezer and into the fridge. The temperature change in the fridge is usually noticed first followed by the freezer.

If the defrost thermostat is bad it can prevent the heater from coming on OR it won’t turn the heater off when it gets too warm. It is clamped to the evaporator coil at the top to sense the temp. If it appears to be misshapen it is bad.
With an ohm meter it should show continuity when cold and none when warm.
You can also bypass the thermostat to see if the heater comes on then. If it does then you know the thermostat is bad and needs replaced.

The defrost heater is located on the evaporator. It is in a tube which is at the bottom and can also go up the sides of the evaporator. On some types you can see a burnt spot if it’s bad. With an ohm meter it should show continuity from end to end when disconnected from the wiring in the freezer. You can also test the wiring for voltage when it’s in the defrost mode.

If you have a defrost timer you can test it. It can be located under the fridge behind the kick panel on the front. Some are in the fridge with the controls at the top. You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer because that means the timer is not running. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.

If you have an adaptive defrost control instead of a timer, replace it if the heater and thermostat test good. It is located in the fridge with the controls in some models and on the back in others.

Nov 27, 2009 | Washing Machines

1 Answer

Ice forms on food in back of frig.


Normal 0 MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-fareast-font-family:"Times New Roman";} The fridge gets its cold air from the freezer through a vent(damper) between the freezer and fridge.The fan in the freezer blows air through it. Make sure this fan is running. You may have to hold the door switch in for it to run. There is a flap you adjust with the fridge temp. control. Make sure it's opening and closing when you adjust the fridge temp.
The problem could be the electronic control if you have one or the mechanical linkages.

Nov 25, 2009 | Washing Machines

1 Answer

LG refrigerator freezer temperature adjust does not work


The fridge gets its cold air from the freezer through a vent(damper) between the freezer and fridge.The fan in the freezer blows air through it. Make sure this fan is running. You may have to hold the door switch in for it to run. There is a flap you adjust with the fridge temp. control. Make sure it's opening and closing when you adjust the fridge temp.
The problem could be the electronic control if you have one or the mechanical linkages.

Nov 13, 2009 | Washing Machines

1 Answer

My performa refrigerator,on top,of unit is freezing all the food .where should the dial be set?


The fridge section shouldn't ever freeze anything.
The fridge gets its cold air from the freezer through a vent(damper) between the freezer and fridge.The fan in the freezer blows air through it. There is a flap you adjust with the fridge temp. control. Make sure it's opening and closing when you adjust the fridge temp ..

Sep 02, 2009 | Maytag Performa PAV2200

1 Answer

Fridge stops working when power goes out.


It sounds like maybe the freezer fan is coming back on ??? Do you hear it in freezer?? I would recommend having it looked at ----this definately doesnt sound normal.

Jan 16, 2008 | Kenmore Elite 21082

Not finding what you are looking for?
Washing Machines Logo

Related Topics:

428 people viewed this question

Ask a Question

Usually answered in minutes!

Top Maytag Washing Machines Experts

Richard Roth
Richard Roth

Level 3 Expert

9472 Answers

Al Clark

Level 2 Expert

290 Answers

Todd Marr
Todd Marr

Level 2 Expert

77 Answers

Are you a Maytag Washing Machine Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...