Question about GE (PSS26MSRSS) Side by Side Refrigerator

1 Answer

Freezer GE model tfx25nrdaww has a freezer problem. When unit defrosts it condenses water and cubes begin to melt. Then after defrost it freezes condensate and ice cubes together. Motor to move ice out is frozen also. Refrigerator works fine. Is the freezer fan suppose to operate during defrost cycle?

Posted by on

  • Anonymous Apr 06, 2009

    I have GE SSS25KFMDWW with the same symptoms except I'm not sure whether the freezer fan runs during the defrost cycle. I'll check. To me it appears the defrost cycle is too long. How long should the defrost cycle be, and how often should the defrost cycle occur? What is the maximum temperature the freezer should reach in the defrost mode?

×

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    MVP:

    An expert that gotĀ 5 achievements.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Contributor
  • 54 Answers

If the freezer is in defrost then the freezer fan should be off. Only on the electronic will the freezer fan come on in defrost but the freezer door has to be held open for 3 min before the fan comes on

Posted on Jul 03, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Ice build-up in bottom of freezer section.


your defrost drain on the freezer side is stopped up causing the drain to freeze over then eventually running out on the floor during the defrost cycle. Locate the drain at the back of the freezer and thaw it out using hot water. Using a screw driver or other object gently push down into the defrost hole and dislodge whatever is stuck there.

An air hose with good air pressure may also work well. When the drain line is clear you should be able to pour water through it freely.

Jun 30, 2010 | Whirlpool 25.6 cu. ft. Side-by-Side...

1 Answer

I have a GE refrigerator with water and ice through the door. the water through the door has stopped working. the ice cube section is functioning.


A common fault on some GE models is that the water line freezes where it passes through the freezer. The fix is to leave the lamp for the water dispenser on overnight, or defrost the unit manually.

Sometimes you can fix this with a hairdryer, but this can cause fire/melted plastic/electrocution issues.

Oct 21, 2009 | GE (PSS26MSRSS) Side by Side Refrigerator

2 Answers

Water is leaking in the freezer underneath the vegetable bin. Anybody knows what the problem maybe and how to fix it?- GE MAKE 685 ENERGYSTAR


I believe your defrost condensate drain has a blockage of ice and will need to be defrosted and clean the condensate line from the freezer to the condensate collection plate below your refrigerator. Most times the blockage begins slowly until the opening of the drain hole under the evaporator freezes itself shut. Below is a link to some solutions I have collected over a period of time. Also has a short movie that makes the repair look simpler. There are many reasons for this happening for example water leaking from a water supply line for the dispenser or ice maker, a crack in the defrost pan, water leaking inside and draining through the refrigerator cabinet, but most are caused by a defrost drain line blockage. Below is a link that may be helpful so try to take it all in and use the parts that most refer to your specific problem, Thanks Sea Breeze
click on link below

Sep 22, 2009 | GE Profile¿ Energy Star® 25.5...

1 Answer

Freezer coils frost up within minutes after being turned back on


Your evaporator coils frost up in normal use and every eight hours or so the entire unit shuts down and the defrost heater comes on to melt the frost. This cycle last about 20 minutes. The melted frost drips into a drain pan and through a drain tube to the drain tray under the freezer/refrigerator where it's evaporated by the condenser fan.

If the evaporator coils behind the back panel of the freezer are icing up because of auto defrost failure that will stop the circulation of cold air and eventually affect the freezer too.

check defrost timer, defrost heater, defrost thermostat. In most newer models the timer has been replaced by an electronic control board. If the heater and thermostat are ok it’ll be the control.

You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.

How to check everything
http://www.acmehowto.com/howto/appliance/refrigerator/refrigerator.php




Aug 31, 2009 | Bosch Classixx KGV28323 Bottom Freezer...

1 Answer

I have a GE Model #GSL25JFPABS fridge. My freezer has been frosting up for quite some time with the ice cubes melting a bit and freezing together. Recently the fridge side has also been warming once in a...


Is the freezer cold enough? Should be close to 10 degrees.
Is there water or ice in the ice mold? If not put water in it and see if it dumps the ice after it’s frozen. If there is ice, lift the cut off arm and let it drop to see if it will start.
If it does dump the ice but don’t refill with water.
Try swapping the wires on the dual water inlet valve. Then try the water dispenser. The water should go to the ice maker. This will tell you weather or not the ice maker valve is working and if the line is clear.
How to check everything
http://www.acmehowto.com/howto/appliance/refrigerator/refrigerator.php

If the evaporator coils behind the back panel of the freezer are icing up because of auto defrost failure that will stop the circulation of cold air and eventually affect the freezer too.

check defrost timer, defrost heater, defrost thermostat. In most newer models the timer has been replaced by an electronic control board. If the heater and thermostat are ok it’ll be the control.

You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.

Aug 29, 2009 | GE GSL25JFPBS Side by Side Refrigerator

1 Answer

GE REFRIG. MODEL#TFX30PRYAA. side by side both


It sounds like your defrost control timer is working, but your defrost heater is most likely burnt out. It is a part number WR51X443
and is located behind the back wall inside the freezer. Turning the refrig off for 24 hours helped melt some of the accumulated frost, but not all. You will have to take that back cover off inside the freezer and melt all the frost with a hair blower, replace the defrost heater and reassemble.

Jul 01, 2009 | Refrigerators

1 Answer

Freezer cool but not freezing


Your evaporator coils frost up in normal use and every eight hours or so the entire unit shuts down and the defrost heater comes on to melt the frost. This cycle last about 20 minutes. The melted frost drips into a drain pan and through a drain tube to the drain tray under the freezer/refrigerator where it's evaporated by the condenser fan.


If the evaporator coils behind the back panel of the freezer are icing up because of auto defrost failure that will stop the circulation of cold air
check defrost timer, defrost heater, defrost thermostat. In most newer models they don't have the timer but an electronic device which replaces the timer.


Jun 30, 2009 | Frigidaire FRT21S6A Top Freezer...

1 Answer

Water "pouring" from freezer condenser


sounds like drain in freezer is clogged and has iced over

so when unit goes into defrost water leaks into freezer bottom and freezes

you can either shut off fridge for a day and let ice in drain melt
and hopefully clear line

or u can take back cover off freezer section pour hot water in drain pan and make sure drain hole is cleared and draining down to pan

Jun 21, 2008 | Sub-Zero 611 / O Bottom Freezer...

2 Answers

Refrigerator condensation


I have a Kenmore Coldspot Model 70262990. When I get wet shelves (water, not just condensation), I was able to trace my source to the cold air vent from the freezer. In my case, the water melts from the evaporator and collects in the rear lower section of the freezer. It is "supposed" to go down the drain tube. However I had the drain hole freeze over. Then additional water from the defrost cycle would accumulate in the freezer floor (under the plastic floor) and eventually find its way down the cold air vent between the freezer and refrigerator section. You'll need to unplug the unit, take the plastic floor out of the freezer, remove the evaporator panel to access the defrost drain, melt the frozen water (hair drier works nice), and remove all the water (towel/sponge & bucket). Make sure the drain is not frozen and not blocked. Then put it back together and plug it in.

Does anyone know how to stop the drain tube from freezing over?

Good luck.

Mar 11, 2008 | Refrigerators

Not finding what you are looking for?
GE (PSS26MSRSS) Side by Side Refrigerator Logo

267 people viewed this question

Ask a Question

Usually answered in minutes!

Top Refrigerators Experts