Question about Microsoft Windows Vista Ultimate Edition

1 Answer

HyperTerminal to control serial devices

Hello Tom,

I urgently required HyperTerminal to control serial devices, unable to find out in Vista, please suggest some alternative.

Like to hear from you soon.

Thanks,
Mayank

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Expert
  • 63 Answers

HyperTerminal is not included in Windows Vista, but can be purchased separately. One such product is located here:

http://www.hilgraeve.com/hyperterminal.html

Posted on Jun 17, 2008

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Hello Sir,I want to buy two engines for the blower of split type model AC 18000 BTU , two remote control and two electrical panel of same model.Kindly send me the quotation of the articles and the...


Hello Sir,I want to buy two engines for the blower of split type model AC 18000 BTU , two remote control and two electrical panel of same model.Kindly send me the quotation of the articles and the shipping cost through DHL and normal shipment .Its urgent. I have already sent this mail to Mr Tom several times but he has not reply me. Hope you will reply me and do the needful because I need the parts urgently for my client.I have bought the AC from your company and I am facing lots of difficulties with my client because of the parts are not available .Regards Sameer Sobratee

Apr 25, 2014 | YANCHENG AOCHI Solar Air Conditioning Wall...

1 Answer

What is the requirement sd card to download tom tom navigator


Min System Requirements for Tom Tom Navigator are as below:-

Windows 2000, XP, Vista, or Windows 7 (newest servicepacks required)
Pentium III or higher
256 MB RAM, 512 recommended
Internet connection (Broadband - DSL/cable/LAN) for downloading updates, maps or services
The TomTom HOME software is a 20MB download requiring 50MB of disk space when installed

For NAVIGATOR 6 devices, the system requirements for Windows are:

Windows XP, 2000, Vista or Windows 7 (newest servicepacks required)
500 MHz processor or better
128 MB RAM
Internet connection (preferably broadband - DSL/Cable/LAN) for downloading updates maps or services
Internet Explorer version 5.0 or higher

Please note that the following MOBILE & NAVIGATOR versions are not supported by TomTom HOME:

MOBILE
MOBILE 5
NAVIGATOR 1
NAVIGATOR 2
NAVIGATOR 3
NAVIGATOR 2004
NAVIGATOR 5

Dec 19, 2010 | Computers & Internet

1 Answer

My Seneo 3220 has changed its mac and gone to Realtek,can not log on to it any more,think its lost Engenius software. nigel 2205


I have no idea what it means for a Senao to "go to Realtek."
Here is the factory reset procedure for the Senao EOC-3220:

An RS-232 null modem serial cable is required for this procedure.


1. Connect the EOC-3220 to your computer with a null modem serial cable.


2. Start a HyperTerminal session: Click Start and then select Programs -> Accessories -> Communications -> HyperTerminal.


3. After the HyperTerminal window appears:


a. Give this new connection a name. Ex: EOC-3220.


b. Select correct COM port. Ex:COM1.


c. Set baud rate as "38400", data bits "8", parity "none", stop bits "1", and flow control as "None". Then press "OK" to bring up the HyperTerminal window.


4. Wait until the "#" is displayed in the HyperTerminal window.


5. Type "flash reset", then hit enter.


6. Type "reboot", then hit enter. After the device reboots, all settings will be at factory default.

Oct 25, 2010 | EnGenius EOC-3220 (EOC3220)

1 Answer

Serial port does not work?


most likely, serial port is faulty. things you can try: update chipset driver, bios, reset BIOS settings, then test serial device through hyperterminal. if the device response through hyperterminal,

Aug 30, 2010 | Panasonic Toughbook CF-51 Notebook

2 Answers

How to use hyperterminal


Run HyperTerminal in Windows by going to Start > Programs > Accessories > Communications > HyperTerminal.
After clicking on the HyperTerminal icon, you will see this window:
hyperterminal_1_small.jpg
HyperTerminal prompts you to create a new connection. Note that this is not required but let’s go ahead and do it.

Type in the word cisco for the connection name and click OK.
Connect your Cisco device to your PC’s COM1 port but don’t turn it on yet. On the next window that appears, make sure that the “Connect Using” field says COM1 and click OK.
hyperterminal_2_small.jpg
On the next window, change the Baud rate to 9600 and click OK.
hyperterminal_3_small.jpg
Now, turn on your Cisco device. In the HyperTerminal window, you should see the boot up process for your device, like this:
hyperterminal_4_small.jpg
//'); //]]> document.write(''); CollectiveMedia.createAndAttachAd("ns-74737014_1271195234","http://ad.doubleclick.net/adj/ns.petri/archive;net=ns;u=,ns-74737014_1271195234,11286e7f1d8af7d,ce_mobile_blackberry,;;kw=;tile=2;ord1=504214;sz=300x250,336x280;ppos=BTF;contx=ce_mobile_blackberry;btg=;ord=3760843785557546?","300","250,336",false); archive;ppos=btf;kw=;tile=2;sz=300x250,336x280;ord=123456789??\ You have successfully configured HyperTerminal and connected to your Cisco device.
When you are done and try to close out HyperTerminal, you will be asked if you want to save this connection. I suggest saving it with the name you gave it, cisco, so that you don’t have to configure it again next time.

Apr 13, 2010 | Cisco Aironet 1142 (AIR-LAP1142N-A-K9)...

1 Answer

I am using nokia n72 and recently i load smartmovie4.01 but now please give me unlock key device Serial Number :- 359570013235147 please give me urgently


am using nokia n6233 and please give me unlock key device Serial Number :-352915020870088 please give me urgently

Apr 30, 2009 | Nokia N72 Cellular Phone

1 Answer

Resetting EnGenius EOC 3610


Dear Venmattey,
please follow these steps, it works:

1. Connect the EOC-3610 to your computer with a null modem serial cable.

2.Start a HyperTerminal session: Click Start and then select Programs-> Accessories -> Communications -> HyperTerminal.

3. After the HyperTerminal window appears:
a. Give this new connection a name. Ex: EOC-3610.
b. Select correct COM port. Ex:COM1.
c.Set baud rate as "38400", data bits "8", parity "none", stop bits "1",and flow control as "None". Then press “OK” to bring up theHyperTerminal window.
d. Unplug the power on the POE injector and wait 5 seconds then plug the power back in.

4. Wait until the "#" is displayed in the HyperTerminal window.

5. Type "flash reset", then hit enter.

6. Type "reboot", then hit enter. After the device reboots, all settings will be at factory default.

NEW: Keenan Systems has written a software that will soft reset the 3610 series back to factory reset. Thisfree software is provided "AS IS" by Keenan Systems and is notsupported or guaranteed by EnGenius Technologies. Use at your own risk.


Be Happy Always

Regards

Dec 03, 2008 | EnGenius Computers & Internet

1 Answer

Hyperterminal


bring up hyperterminal it will open a connection window if there is a modem inyour system it will default to it select in the down arrow to the left com1.
this will open the com port window.
at which time you should select the settings accroding to your connection. bits persecond data bits flow control. all this should be within your installation instructions.
good luck

Jun 24, 2008 | Quatech SSU-100 Serial Adapter

1 Answer

AP Mode Problems


Probably you have to learn that there are various people looking for an access of the internet through your facilities. Anyway, inorder to solve your problem these are the following recommendation I made just for you. Hope this will be helpful.

PHASE I
1.) How do I reset the EOC-3220 / EOC-3220 EXT / EOC-3220+ back to factory default settings? An RS-232 null modem serial cable is required for this procedure.
(where to buy it : http://www.keenansystems.com/store/catalog/product_info.php?cPath=3&products_id=221)

1. Connect the EOC-3220 to your computer with a null modem serial cable.

2. Start a HyperTerminal session: Click Start and then select Programs -> Accessories -> Communications -> HyperTerminal.

3. After the HyperTerminal window appears:
a. Give this new connection a name. Ex: EOC-3220.
b. Select correct COM port. Ex:COM1.
c. Set baud rate as "38400", data bits "8", parity "none", stop bits "1", and flow control as "None". Then press “OK” to bring up the HyperTerminal window.

4. Wait until the "#" is displayed in the HyperTerminal window.

5. Type "flash reset", then hit enter.

6. Type "reboot", then hit enter. After the device reboots, all settings will be at factory default.

Phase II

1.) Since that you already reseted the AP you need to use the default IP which is 192.168.1.1 user: admin password: admin

2.) Make it sure you need to use different IP such as 72.10.251.xxx and the subnet: 255.255.255.xxx

3.) The idea of configuration in come from your own desire which was no body can no longer try to match your network IP so that there will be no body access your AP anymore without your knowledge.

4.) You need to make you SSID invisible to everyone inorder no body no longer able to reach your SSID by setting up basic setting which is transparent to everyone.

5) And lastly change the default user and password of your AP.

Good Luck

Nov 24, 2007 | EnGenius EOC-3220 (EOC3220)

Not finding what you are looking for?
Microsoft Windows Vista Ultimate Edition Logo

Related Topics:

144 people viewed this question

Ask a Question

Usually answered in minutes!

Top Microsoft Computers & Internet Experts

micky dee

Level 3 Expert

2642 Answers

Les Dickinson
Les Dickinson

Level 3 Expert

18375 Answers

Brian Sullivan
Brian Sullivan

Level 3 Expert

27725 Answers

Are you a Microsoft Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...