Question about Behringer XENYX 2442FX Mixer
You have likely lost one, probably the +15 volt power supply... This is possibly a shorted component or a short on the circuit board causing this. It takes some skills at troubleshooting to find this. Sometimes using a thermal imaging camera will show hot spot... other times you have to search with a millivoltmeter. The rude solo light is driven by an op amp that uses both polarities of 15 volts and to turn it on it pulls negative... Hence I suspect the +15 is missing.
Posted on Nov 06, 2010
Hi,
A 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
The service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Good luck!
Posted on Jan 02, 2017
Feb 15, 2015 | Behringer XENYX 2442FX Mixer
Mar 05, 2014 | Behringer XENYX 2442FX Mixer
May 18, 2012 | Behringer XENYX 2442FX Mixer
Nov 20, 2011 | Behringer XENYX 2442FX Mixer
Aug 30, 2011 | Behringer XENYX 2442FX Mixer
Jul 26, 2011 | Behringer XENYX 2442FX Mixer
Jul 16, 2011 | Behringer XENYX 2442FX Mixer
Apr 14, 2011 | Behringer XENYX 2442FX Mixer
Feb 13, 2011 | Behringer XENYX 2442FX Mixer
Nov 20, 2010 | Behringer XENYX 2442FX Mixer
Jun 11, 2014 | Behringer XENYX 2442FX Mixer
735 people viewed this question
Usually answered in minutes!
×