Question about Generac Guardian Series 5502 10 kW Emergency Power System 5502

1 Answer

It is a Guardian-Generac Generator Model 0052410. It does not start. I tried a manual start test and all I get is a clicking sound comeing from the PCB Assy. controller and the generator does not crank. A FLASHING RED LIGHT shows NO RPM SENSE. I checked the oil level and its ok, checked the natural gas its ok and the battery is ok. Thanks, Jerry.

Posted by on

  • jraines49 Nov 02, 2010

    Thank You. I will order a new regulator.

×

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 10,319 Answers

My cousin has one of these models and the same thing happened to his. It was the natural gas regulator valve that went out. He could hear the clicking noise which is the spark ignitor trying to ignite the gas pilot light. After replacing the gas regulator the unit work fine as ever

Posted on Nov 02, 2010

×

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

I need a rectifier or avr for generac 3500 xl genarator


Ebay and various places including the maker..

  • VOLTAGE-REGULATOR-3000-3500-WATT-GENERATOR-GENERATORS ... www.ebay.com/sch/sis.html?_nkw=VOLTAGE-REGULATOR-3000-3500-WATT... VOLTAGE-REGULATOR-3000-3500-WATT-GENERATOR ... New listing 3500 Watt Generator AVR Automatic ... 3500W Generator AVR Automatic Voltage Rectifier ...
  • 3500 W 3500 Watt Generator AVR Automatic Voltage Regulator ... https://sites.google.com/site/kltthtyz0i04cd/3500-w-3500-watt... Generac Guardian 22kW Standby Generator NG ... Previously Pay for Shop 3500 W 3500 Watt Generator AVR Automatic Voltage Regulator Rectifier 3.5KW Generator AVR ...
  • How to test your Electricity Generator's AVR, Brushes and ... www.youtube.com/watch?v=tC_LrrZcx38
    • BY GENERATOR GURU
    • 9 MIN
    • 454K VIEWS
    2011-10-21 · Video embedded · When your electricity Generator stops producing power, ... How to test your Electricity Generator's AVR, ... Generac iQ: The Quietest Generator ...
  • Generac Power Systems - Home www.generac.com Generac manufactures the widest range of power products in the marketplace including portable, RV, residential, commercial and industrial generators.
  • Generac Guardian Generator Voltage Regulator Rectifier ... www.ebay.com/sch/sis.html?_nkw=Generac+Guardian+Generator+Voltage... Generac Guardian Generator Voltage Regulator Rectifier ... Generac Guardian Generator Voltage Regulator Rectifier ... Generac Guardian Generator Voltage Regulator ...
  • Automatic Voltage Regulator (AVR) for Generators portable.generatorguide.net/avr.html How automatic voltage regulator (AVR) works in portable generators: ... here you can see a reverse engineered Generac regulator that uses SCRs and UJT.
  • Diagnosing A Generator That Has No Power Output. - YouTube Youtube
    • BY THEDIYGUYDOTNET
    • 3 MIN
    • 150K VIEWS
    2012-11-12 · Video embedded · Diagnosing A Generator That Has No Power Output. ... How to test your Electricity Generator's AVR, ... Generac Portable Generator ...
  • GENERATOR Diagram & Parts List for Model 3500xl Generac ... www.searspartsdirect.com > ... > 3500XL GENERAC Generator-Parts GENERATOR Diagram and Parts List for GENERAC Generator-Parts model # 3500XL ... Generator rectifier Part #: ... Generator voltage regulator Part #: ...


  • Jun 28, 2016 | Generac Electrical Supplies

    1 Answer

    Generator hard to start and sputters like its missing


    About 15,000 results (0.73 seconds) Search Results

      2 - Generac : Questions, Answers, How To, FAQs, Tips ...

      answers.generac.com/answers/1506-en_us/searchquestions.htm?...
      Can I run an 8kw standby generator on a 100 lb propane tank? 2 answers ... What am I getting for the extra cost of the Guardian unit? ... The engine starts hard and runs rough. 1. Air ... On auto start, unit sputters and I smell gas. ... Does the gas and electrical feed into the unit from the back as previous air cooled units?

      2 - Generac Questions and Answers

      answers.generac.com/answers/1506.../generac.../questions.htm?...
      On auto start, unit sputters and I smell gas. .... The 20kW automatic standby generator has the option to delay start up during an ... This is for a guardian 20kw. ....has been designed to make the battery installation and removal so difficult? ... The air cooled generators are designed to allow for the smallest footprint while still ...

      3 - Generac Questions and Answers

      answers.generac.com/answers/1506.../generac.../questions.htm?...
      Generac's Guardian Series 17kw automatic standby generator does not come with a.... The automatic response features of our air-cooled units initiates the unit's startup,.... This week I tried the same and it tries to start but just sputters and fails until .... A C delayed start still chocks 17kw generator would a hard start kit help?

      On auto start, unit sputters and I smell gas. On manual start ...

    Feb 08, 2016 | Generac Guardian Air-Cooled Standby...

    1 Answer

    Why does it crank and almost start on 1st try?


    Generac Generator Troubleshooting - YouTube

    ? 1:39
    https://www.youtube.com/watch?v=AKN2dc59cxY
    Dec 20, 2013 - Uploaded by Appliance Princess
    I want to learn about Generac generator troubleshooting. ... I have a 16 kW propane fueled standby air-cooled generator. ... I have a brand new generac 20K guardian Evolution and the first time my power went out my generac ...

    Generac Power Systems - ConsumerAffairs.com

    www.consumeraffairs.com > Homeowners > Utilities

    Rating: 1.3 - ‎26 votes
    Hey, Generac, make a change and start making generators that work, don't cost .....Standby generators are not supposed to be used as a primary power source ... and three months ago, I spent $4,000 to have a Guardian generator installed at ...

    Generac standby generator - Propane - wont start?? - DoItYourself ...

    www.doityourself.com/.../487838-generac-standby-generator-propane-w...
    Feb 4, 2013 - I have a Generac 4LM41A standby generator that I need help introubleshooting and repairing. It is about 12 years old and hasn't been used ...

    141 GENERAC complaints and reviews @ P'ed Consumer


    Dec 12, 2015 | Generac GUARDIAN Standby Generator 10 kW/9...

    1 Answer

    How to change the fuel filter on guardian quietpact rv generator


    Dec 05, 2015 | Generac Electrical Supplies

    1 Answer

    How to replace battery in a generac standby 8kw generator


    Switch generator to off. Remove 7.5A fuse. Disconnect Negative (-) battery terminal first and then Positive terminal (+). slide battery out the front (may be a tight fit) and install the new battery reversing removal steps. Connect (+) first and (-) last. Reinstall 7.5A fuse and switch to manual to start and test run.

    Sep 06, 2013 | Generac Guardian 8kw Standby Generator

    3 Answers

    Generac gardian model:005885-0 running rough


    Check the spark plugs, ignition coil etc and try to start it manually.

    Jun 15, 2010 | Generac Guardian Quietsource 25,000 Watt...

    1 Answer

    After shutting it down for summer months it will not start, only makes click noise i have a guardian generac 7000kw home standby generator it is not the limit switch


    sound like a dead battery, or dirty / bad connection from battery- try jumping it with a car battery-- if that doesn't work, check battery connection, loose or corroded leads.. otherwise it is solenoid or starter or starter switch

    Sep 29, 2009 | Generac Guardian 084464 - limit switch

    1 Answer

    Generac Guardian 15kW Generator


    That sounds just about right, if the relay contacts get welded together it sometimes takes out the driver on the printed circuit board. As you found out, 12vdc from 23 to 194 makes the transfer switch move to the Generator position, relay not energized makes the ATS move to the Normal position.

    You can make a nice test function by installing a 10 amp contact switch in series with either the N1 or N2 terminals. When the switch is open the generator thinks the Normal power has failed.

    Regards,
    Carl

    Jan 20, 2009 | Generac Guardian 100 Amp Transfer Switch...

    Not finding what you are looking for?
    Generac Guardian Series 5502  10 kW Emergency Power System  5502 Logo

    Related Topics:

    849 people viewed this question

    Ask a Question

    Usually answered in minutes!

    Top Generac Guardian Electrical Supplies Experts

    Craig Butler
    Craig Butler

    Level 3 Expert

    1723 Answers

    epangan29

    Level 2 Expert

    112 Answers

    yadayada
    yadayada

    Level 3 Expert

    80608 Answers

    Are you a Generac Guardian Electrical Supply Expert? Answer questions, earn points and help others

    Answer questions

    Manuals & User Guides

    Loading...