1 Answer

Goldstar Room Air Conditioner problem...

So I'm barely noticing this but my Air Condtioner seems to turn on and off more than usual. Before coming onto here to put up my question, someone else told me this is normal to save energy while another said this wasn't. My AC doesn't have a display to see the temperature, just a dial nob to 1-10 on 10 being the coolest of course and another setting for Hi and Low speed for the fan. It does throw cool air but only for about 2min and then it will shut off and the fan will be the only thing blowing for about 5min until again the cool air kicks in. The filter is clean and the coils too as well. Does it need any additional cleaning from within? Also not sure if it's because I've changed the location of my AC to another window in the same room which has the sun contantly hitting on the AC more than it did on it's original location that was placed in. If so, will the sun have any affect on it's performance? Perhaps I may need to put back the AC to the window where the sun was less to be hitting it directly.

Posted by on

  • Andumeba Jun 14, 2008

    Thanks for the help. Perhaps it is time to get a new AC for the room. I mean this one is not that old, ok maybe like 2yrs or 3 but we had our very old AC that we have used for 10years in the livingroom and it runs like new...oh well. Thanks.

×

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

    Scholar:

    An expert who has written 20 answers of more than 400 characters.

  • Expert
  • 104 Answers

It sounds to me like you have a weak run capacitor on the compressor. This will cause the compressor to be able to run for a short period, but it will be overworking itself to compensate for the weak capacitor. It overheats, shuts off to protect itself, cools down and restarts again. If you have it set to 10 I don't think you would be comfortable in the room if the thermostat was satisfying and turning the unit off. An a/c tech can replace the weak capacitor, but the cost of repair will probably rival that of a new unit.

Posted on Jun 12, 2008

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

The air from my air conditioner doesn't seem to be coming out as cold as it was when i first bought it. It seems to take a lot longer to cool off my living room, i dont know if it needs freon to be...


Its going to take a hile to cool down a hot room . have you cehck the filter? while your at it wash it out . what is the temp of the room and the temp of the air coming out of the unit?

Jul 22, 2011 | Goldstar Heating & Cooling

1 Answer

My A.C. unit is not cooling my room like it was a couple of days ago it just throws out air that is not cold and when I turn it on it the air that comes out on cool mode is like the air that comes out in...


Hi,

Here is a tip about troubleshooting your air conditioner...
There are many things that can cause your air conditioner not to cool...

Air Conditioner Trouble - Review the Possibilities

heatman101

Sep 27, 2010 | Goldstar Heating & Cooling

1 Answer

Does not cool room.


Goldstar WG5000 air conditioners use an R22 refrigerant. A charge kit containing the gauges needed to properly fill the unit, and the refrigerant tank/cartridge can be purchased to fill the air conditioner.

Jun 03, 2010 | Goldstar WG5000 Air Conditioner

1 Answer

Fujitsu Air CONDITIONER LEAKING AT FRONT INTO ROOM MODEL NO AST18


Ithought the service was free from the advertising..silly me...I use trades people who come and tell me what is wrong , that is a free quote, then I decide what I can afford.
Thank youfor your time.

Feb 01, 2010 | Fujitsu 24C1 Air Conditioner

1 Answer

Trying to set air conditioner


it shouldnt run for that long if it is sized right for the room in the first place. Does it not come back on after it runs for 30 to 40 mins?
sounds as though it is not the correct size for the room to me

Jun 30, 2008 | Goldstar KG6000R Window Air Conditioner

1 Answer

GOLDSTAR BG5200ER


Measure the temp of the air blowing out. It should be 20 degrees lower than the intake air at the filter. If not, we need to dig deeper.

Aug 14, 2007 | Goldstar WG5200ER Air Conditioner

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

242 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2364 Answers

Dan Webster
Dan Webster

Level 3 Expert

8205 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...