We have a Carrier Series 38, it worked fine last year now this year we turned it on and the fan will run for a minute then stop and then start again. Someone told us to try a new thermostat so we did and it didn't fix anything....

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

  • Expert
  • 95 Answers

Probably need a new fan motor, sounds like it is overheating. This can happen if the bearings are too tight. Not something you can fix just replace. Need an amp meter to check the amp draw on the motor

Posted on Jun 10, 2008

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Condenser fan replaced one year ago, fan not turning but can hear motor


the answer to your problem is most likely the motor start capacitor. A AC motor can run in both directions. The start capacitor is used to cause the current to lag behined the voltage which determines the direction the motor will turn. Its posible the start and run capacitors are in one can. so changing one will change the other. However look for a wiring diagram. Do not asume that both capacitors are wired in properly. They may be fighting one another causeing premature failure.

Sep 18, 2012 | Carrier 38CKC036 Air Conditioner

1 Answer

8 year old Air conditioner only used in the last 3 years more than a week or two a year. capacitor changed last year Unit was working a week ago now fan is not turning, Connector clicks when turn on...


Outdoor units require there own power supply, check the breaker panel and the fuses in the disconnect switch box next to the unit if there are fused, If the capacitor that was changed last year was not the right rating or configuration it may need to be corrected. One of the most common mistakes is to find a dual run capacitor with on side not functioning and jump in a capacitor for the non functioning side, if this was done it needs to be corrected with the proper capacitor or capacitors.

May 24, 2011 | Carrier 38CKC036 Air Conditioner

1 Answer

I have a 10-year old Carrier Gas pack Model #48GS024060301. Turned on the heat for the first time this season and the unit did not turn on. I was able to turn on the house circulation fan and since it...


If the induction motor ain't going I would look for a blown 3 amp (purple) fuse on the control board. If that was good I would check if any of the roll out switches were tripped. If a rollout switch was tripped check or air restrictions somewhere.

Oct 17, 2010 | Heating & Cooling

2 Answers

I have a Carrier RV Air V air conditioner. I turn


Have fan start capacitor checked/replaced by licensed tech, or electrician as they are very dangerous to work with if not experienced and can give a very high voltage shock, that could be fatal. They basically store and increase voltage to higher range for start up of fan and compressor.

Jun 01, 2010 | Dometic Rooftop RV Air Conditioner

1 Answer

Possible Contactor Issue


Sounds like a bad fan switch in your unit. That unit has a fan board in it that is time delay on and off. Turn the fan to the on position and let it run all the time. If it keeps temp and does not shut off it is the fan realy board. The board also controls the compressor. Check that first and then the tsat. Russ

Jul 24, 2009 | Carrier 38CKC042 Air Conditioner

1 Answer

Carrier Weathermaker SX model 58SX060-CC Blower runs all the time


Remove all power from the furnace, it is likely the brain in the furnace is need of being reset, from the battery replacement, why did you change the battery, was there an indicator telling you to change it?

Many times just removing all the power to the furnace will do the trick with a reset, if not let me know and we will go from there, but it sounds like the main brain is confused or bad, more likely confused, so try the power removed first.

Than let me know wbwill@sbcglobal.net

Oct 22, 2008 | Carrier XHB123D X/Y Series Heat/Cool Air...

1 Answer

Central Air Conditioner


Turn the power to the indoor unit off. Remove the cover where the fan is. Feel the motor of the fan. If it is very hot the bearings have likely gone out. If the fan is cool to the touch I would call a service company because you likely have an electrical problem that will require some training to solve.

Jul 09, 2008 | Carrier 38CKC042 Air Conditioner

Not finding what you are looking for?
Carrier 38BRC048 Air Conditioner Logo

Related Topics:

82 people viewed this question

Ask a Question

Usually answered in minutes!

Top Carrier Heating & Cooling Experts

Dan Webster
Dan Webster

Level 3 Expert

8205 Answers

Donni Steen

Level 3 Expert

659 Answers

Bill Long

Level 3 Expert

587 Answers

Are you a Carrier Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...