Tv does not turn on

I have a Sony Triniton, I think it is the 36in model, and it will not turn on. When you go to turn it on it makes the sound like it is going to come on , but it does not. I will wait a while sometimes and try again and nothing happen. There is a red blinking light that indicated stand by, and will blnk for 6 or 7 times. Do you have any ideas on this problem? Thanks

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Genius:

    An expert who has answered 1,000 questions.

  • Sony Master
  • 1,635 Answers

The power supply is in the protect mode. This is most likely a scan amplifier failure. Most of the time it would be in the horizontal output section. If the CRT is shorted, or there is a failure in the vertical section, this type of error will show. When there are scan amplifier failures, sometimes the power supply is also damaged and requires service.

Jerry G.

Posted on Oct 01, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My Sony triniton tv won't power on because the


Every set has a standby power supply that runs 7/24 when set is plugged in---it means in this case a main power board or something associated with that is not working, Set is not making it from just standby to full on.

Dec 23, 2012 | Standard (CRT) Televisions

1 Answer

Hi i have a Sony tv and it doesn't turn on anymore there's only a red light flashing and the sign shows


Visit the site named 'Electro-help' for more details. Click this link. View it in 'Flip card' option, which can be selected from the drop down box menu by the [Sidebar] tag, at the top left corner of the display window. It will make search easy. There are more than 975 posts to different brand TVs now.

Sep 09, 2012 | Sony FD Trinitron WEGA KV-27HS420 27" TV

1 Answer

Stand By timer light continues to blink on Sony Triniton TV


That problem comes up when one or both of the convergence IC's are burnt ... it normally has an "STK" number on it screwed onto some large aluminium heatsink ..... however if you venture to change it get back to me ... I'll try to guide you through ....

May 23, 2009 | Sony FD Trinitron WEGA KV-34HS420 34" TV

1 Answer

Sony Trinitron XBR, Stand By Mode?


Generically, the 6 or 7 blinks usually indicate a problem with the horizontal circuit. In order to provide accurate diagnosis and suggested solutions, the exact model number is needed. Please update this with tha number and I will post more details.

Thanks,
Dan

Mar 18, 2009 | Standard (CRT) Televisions

1 Answer

Sony Trinitron XBR, Stand By Mode?


The 6 or 7 blinks usually indicate a problem in the horizontal circuit. Since the TV recovered once, the problem is most likely to be a bad solder connection in that area. If you can solder, resolder any connections on the board that appear grainy or have rings. That may resolve the problem. If not, update this and we'll look elsewhere for defective parts.

Dan

Sep 16, 2008 | Sony FD Trinitron WEGA KV-36HS500 36" TV

1 Answer

Tv turning off


Hello
Sony FD Triniton Wega KV-36XBR400 service manual has no info for 11 times flash. It has info up to 7 falshes. Please count again. Error codes are in below pictures...

0000abe.jpg a288bbc.jpg
Regards,

Aug 27, 2008 | Sony FD Trinitron WEGA KV-32XBR400 32" TV

5 Answers

Sony Trinitron XBR, Stand By Mode?


Many of the later model Sony TV?s have a built in self-diagnosis function. If the timer/standby indicator is blinking, this could be an indication of a problem with the unit. The diagnostic blinking will occur automatically with no action required by you to engage it. The timing of the blinking you see would be as follows: two to nine blinks, (depending on the fault), about a third of a second apart, then a pause for 3 seconds, then the two to nine blinks about a third of a second apart again. Here is a list of the problems that might have occurred indicated by the number of blinks. The words in parentheses are those, which you will see for each of these faults on a diagnosis screen described later in this article. Unit is dead, No blinks - Problem in the standby power section. Might check fuse, R607, Q601, IC601, R612 and VDR601 (should show open). Continuous blink once a second, no pausing - No reply from the jungle IC301 (data bus is busy, shorted to ground, or held high), IK video path is defective. One blink - not used for the self-diagnosis Two blinks - B+ over current protection (OCP), unit goes to the standby mode then displays the 2 blink fault. Could be a short in the power supply of any of the circuits. Three blinks - B+ over voltage protection (OVP), unit goes to the standby mode then displays the 3 blink fault. This is also a problem in the power supply circuit, check T603 and R672. Four blinks - No vertical Deflection (V STOP), Screen goes to a single horizontal line then the video signal muted. Check IC1509, Q1505 Five blinks - AKB circuit (automatic kine bias), the timer/standby indicator blinks for about 30 seconds then goes to the self-diagnosis function. Something is wrong with the video. Check video out, Q705, 732, 761 and other components on the C board, also check Q218, 219, 220 on the A board. In addition, unit could be in IK blanking, try turning up screen slightly. Six blinks - No Horizontal (H STOP), no raster, goes to the blinking self-diagnosis function immediately. Check C515 & 516 and the jungle IC, IC206. Seven blinks - High voltage shutdown. The high voltage has exceeded 33k and the unit goes immediately into safety shutdown. Check power supply regulation and horizontal circuits. Eight blinks - Problem with the audio (AUDIO), unit goes to standby and blinks the self-diagnosis code. Check IC406 audio amp, PS401, and 402. On some projection models of Sony TV sets, this code means that T8005 (flyback transformer), or the associative components in the high voltage circuits are defective on the D board. Nine blinks - Replace D 6116 and D 6301 on the "G" board, do not resolder as this will fix the problem temporary. Or Panel Module Error or Thermal Error. If it is intermittent 9 blinks, meaning sometimes the TV comes on and other times you get flashing, then change the switching regulator on the "G" board or check connections. Make sure the regulator is -12 or -13 (negitive). Ten blinks - Check Q8014 and Q8013 for shorts, leakage, or bad solder connections on the " D" board. If the transistors are bad, check R8051 and IC8005, also on the "D" board.

May 21, 2008 | Sony FD Trinitron WEGA KV-36XBR800 36" TV

Not finding what you are looking for?

Open Questions:

See all Sony FD Trinitron WEGA KV-36XBR800 36" TV Questions

Sony FD Trinitron WEGA KV-36XBR800 36" TV Logo

Related Topics:

204 people viewed this question

Ask a Question

Usually answered in minutes!

Top Sony Standard (CRT) Televisions Experts

The Knight
The Knight

Level 3 Expert

68368 Answers

Jaime Hernandez

Level 3 Expert

2267 Answers

matt martin
matt martin

Level 3 Expert

1191 Answers

Are you a Sony Standard (CRT) Television Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...