Air conditioner Mod.# AF-S120FX. Runs for a short while then shuts itself off. Readout blinks E1.

Posted by on

2 Answers

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 3,037 Answers

This is the reset procedure, let me know how it works for you

1. Unplug the unit for 5 seconds 2. Hold the power button in until the unit beeps
3. Pull the plug and reconnect a second time.

If that doesn't work 1. Pull the power cord. 2. Hold the MODE button while plugging the unit back in, but do not let go of MODE 3. The unit will beep and start to operate 4. Let go of MODE and depress the Power button to turn it off 5. Press power to turn back on
And one more way

1. Pull the power 2. Hold the power button in for the next bunch of steps - don't let go! 3. Plug the unit back in, it will start, stop, and beep 4. Pull the plug out, don't let go of power 5. Plug the unit back in, it will start, stop and beep 6. Pull the plug out. Let go of power button. 7. Plug the unit back in and power it up. Set controls to your liking.

Posted on Jun 06, 2008

  • Benjamin Patri
    Benjamin Patri Jun 06, 2008

    The reason for the reset, is that it is needed after 720 hours of use and this is the time to clean it also especially the filter but make sure you clean all of the dust out, if none of the reset options work, then let me know

  • Benjamin Patri
    Benjamin Patri Jun 08, 2008

    If you are satisfied with your experience here, then feel free to provide me with some feedback by
    rating my solution. If you need any more help, I would be glad to
    assist you, just ask.





    Thanks for your time and service and I hope you have a Great Day!

×

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Sharp Master
  • 13,433 Answers

The system has run for 750 hours and you have to clean the filter

Posted on Jun 06, 2008

  • 1 more comment 
  • Ekse Jun 06, 2008

    The manual says to clean filter and unplug unit, plug unit back in and code will be reset.

  • Ekse Jun 06, 2008

    sorry that information was out of date, try this





    Unplug unit, clean filter, HOLD DOWN power button and CONTINUE HOLDING while plugging unit back in. Unit will beep. Unplug again, plug back in and resume normal operation

  • jennchick308
    jennchick308 Aug 05, 2012

    This worked for my unit this morning. Thank you so much for the suggestion!

×

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

A/C runs fine for 7-8 minutes, then shuts off


Refrigeration problem. Must be a bad thermostat.

May 11, 2013 | Sharp AF-S120FX Air Conditioner

1 Answer

How much Sharp AF-S120FX Air Conditioner?


The model number you listed has been discontinued by Sharp. So, getting an accurate retail price is difficult. I did see one online marked Clearance for $269.00. But be careful buying discontinued models, as the warranty may only for a short period of time. Also, customer ratings/opinions on this model, dating back to 2005, were not good.

Hope this helps you and thanks for choosing FixYa.

Aug 24, 2011 | Sharp AF-S120FX Air Conditioner

1 Answer

Ac shuts off E1 error message


E1 Error Code -->> Clean Filter

Owners of Sharp air conditioner models AF-S60FX, AF-S80FX, AF-S85FX, and AF-R80FX may experience the following (highly annoying) issue. After 720 hours of fan operation, the error code E1 will appear on the seven segment LED temperature display. This error code is intended as a reminder for the user to clean the air filter. However, because the procedure outlined in the user manual does not clear this error code as indicated, and the appliance has a nonvolatile memory that cannot be reset by simply unplugging it, the user of the appliance will become mightily frustrated, standing in potentially sweltering heat watching the appliance repeatedly shut down in the midst of operation with the "E1" display flashing.

Believe it or not, that is what it does: if you unplug it to remove the "E1" code from the display, and plug it back in and re-start it, it will simply run for anywhere from a few minutes to a few hours, and then merrily shut down again with the same flashing "E1" code.

Many people at this point, having put the manual under the canary or some such, will simply return the unit and never buy another Sharp air conditioner. But for the tech-savvy and search-adept, I offer the following procedure to clear the nefarious E1 indication, and obtain another 720 hours of cooling bliss:
1. Power down the air conditioner using the "power" button on the front panel.
2. Unplug the air conditioner from the wall socket.
3. Hold the front panel "power" button down and plug the air conditioner in. Continue to hold the power button down as the machine goes through a brief test sequence (fan & compressor each come on briefly, etc). There is a "beep" sound at the end of the test sequence, and the machine will be off. At this point, you can release the power button.
4. Unplug the air conditioner.
5. Plug the air conditioner back in.
6. Congratulations! You should now be able to operate the air conditioner normally for another 720 hours, but only if you followed the instructions above exactly.

If you doubt the veracity of this information, or it does not work as expected, you can get it directly from the source at: 1-800-237-4277 (Sharp customer service line). You'll need to call between 7 AM and 7 PM US Central time, and have your model number and serial number ready.

May 28, 2011 | Sharp AF-S120FX Air Conditioner

1 Answer

My AF-S120FX sharp air conditioner will work for about 15 minutes and then stop and the error/problem code E1 shows up. Do you know what this code means and/or how to correct the problem?


Check the outside fan and condenser . condenser must be really clean and fan must operate. Make sure the fan on the evaporator in the house is working as well. Pressures exceed rated running values if not.

Aug 04, 2010 | Sharp AF-S120FX Air Conditioner

1 Answer

E1 WHAT DOES MEAN


E-1- Indoor room temp sensor defective. Replace it.

Jul 29, 2010 | Sharp AF-S120FX Air Conditioner

1 Answer

My Sharp Room Air conditioner (Mod.AF-S120FX-A) when it's starts


Most likely the terrible noise you hear is the compressor starting... Sometimes it is louder than when its runs continuous. Just make sure if the unit is shut off allow a few minutes for the freon to equalize before restarting the unit. Its possible that the Compressor is going out, But as long as it cools and the noise goes away after a minute or so, i wouldn't worry about it to much.

Apr 29, 2009 | Sharp AF-S120FX Air Conditioner

1 Answer

Shutting off


I would try the same solution as the E1 error code, Not sure if it will work, but it seems to be the same issue


1. Power down the air conditioner using the "power" button on the front
panel.
2. Unplug the air conditioner from the wall socket.
3. Hold the front panel "power" button down and plug the air
conditioner in. Continue to hold the power button down as the machine
goes through a brief test sequence (fan & compressor each come on
briefly, etc). There is a "beep" sound at the end of the test sequence,
and the machine will be off. At this point, you can release the power
button.
4. Unplug the air conditioner.
5. Plug the air conditioner back in.
6. Congratulations! You should now be able to operate the air
conditioner normally for another 720 hours, but only if you followed
the instructions above EXACTLY.

Sep 10, 2008 | Sharp AF-S120FX Air Conditioner

2 Answers

Air condition problem


An E1 error is automatically generated after the AC runs for so many hours to remind you to clean the filter. The manual says to clean filter and unplug unit, then plug unit back in and code will be reset.

Aug 02, 2007 | Sharp AF-S120FX Air Conditioner

Not finding what you are looking for?
Air Conditioners Logo

Related Topics:

262 people viewed this question

Ask a Question

Usually answered in minutes!

Top Sharp Air Conditioners Experts

AJMAL KHAN

Level 2 Expert

382 Answers

Tim Whalen

Level 3 Expert

3056 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

21949 Answers

Are you a Sharp Air Conditioner Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...