UNIT RUNS BUT WANT COOL BELOW 50 DEGREES... COMPRESSOR IS RUNNING AND COLD LINE COLD ,HIGH PRESSURE LINE HOT BUT WILL NOT COOL BELOW 50 DEGREES.

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Haier Master
  • 43,501 Answers

Hi,

Many times a freezer and/or refrigeratordo not work right because of a dirty condenser coil...there are also many otherthings that can go wrong. If you are hearing a clicking or buzzing then check out thelast two tips.

If your refrigerator is running but warm, then...

Check out this tip that I wrote about that... it is a great place to starttrouble shooting your unit...and something that you can do rather then callinga repair person to do a simple thing for you...

Refrigerator Condenser Coil Cleaning Refrigerator Repair

Refrigerator Troubleshooting Refrigerator Compressor

Refrigerator Compressor Start Capacitor and Start Relay
Refrigerator or Freezer not Cooling or Getting Cold

heatman101

..

Posted on Oct 17, 2010

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

How to tell if the compressor on your ac unit is running


If you have a split unit, it is fairly simple, just feel the small refrigerant line coming out of the unit. The temperature should be warmer than the surrounding air. If is not running the temperature will be the same as the surrounding air. If you have a package unit, take off the access cover to where the compressor is located. Find the compressor discharge piping to the the condensing coil. It is the smaller of the two major pipes on the side of the compressor. Be careful the temperature of line coming out of a properly operating compressor will be hot enough to cause second degree burns. If the line is very warm to very hot the compressor is running. If you have a set of gauges, attach the RED hose to the high pressure service connection and the other low pressure hose BLUE to the bigger pipe low pressure connection. Make sure the gauges are isolated by shutting the valves. The pressure difference between high and low pressure is normally at least 150 psig diference.

Jun 25, 2014 | Goodman CKL24AR24 Air Conditioner

1 Answer

Location of ac high pressure cutout switch on a 97 Plymouth voyager. Could it be a different problem? Had to replaced the PCM and a couple sensors because of a short in the wiring cluster. Now the ac...


HIGH PRESSURE CUTOFF SWITCH LOCATED ON AC COMPRESSOR DISCHARGE LINE LEADING TO THE CONDENSOR.THE HIGH PRESSURE CUTOFF SWITCH WILL CUT OFF THE AC COMPRESSOR IF SYSTEM PRESSURE RISES TO HIGH CAUSED BY RESTRICTION IN THE REFRIGERANT CIRCUIT OR OVERHEATED CONDENSOR.MAKE SURE COOLING FAN IS RUNNING WHEN THE AC SWITCH IS ON.THE COOLING FAN KEEP CONDENSOR COOL, IF COOLING FAN DONT RUN.YOUR AC WILL STOP BLOWING COLD AIR.HAVE THE REFRIGERANT SYSTEM CHECK OUT.MAKE SURE YOUR LOW SIDE PRESSURE IS 10 - 37 PSI. THE HIGH SIDE PRESSURE SHOULD BE 112 - 210 PSI. CHECK THE AC COMPRESSOR CLUTCH FUSE AND RELAY.

Jul 29, 2011 | Plymouth Voyager Cars & Trucks

1 Answer

The unit will not cool below 78 degrees. How do I check the freon level?


Without refrigeration gauges, you can't check your freon level. You have to check the pressure of the freon, not the level. If you are careful and have a basic knowledge of electricity and moving parts, you can get an idea if you are out of freon. If you remove the lower slotted cover from the refrigerator you will see the condensor coils. This is a radiator that has aluminum fins on the front and will have a fan running behind it. If the compressor is running this condenser coil should be hot to the touch at the top part of the aluminum fins. If the fins are covered with dust and dirt it can cause your cooler to malfunction. Also if the fan is not running the compressor will overheat and quit. If you pull the cooler away from the wall, you can see the compressor in the bottom of the cooler. There are two copper lines leading to the compressor. The small line goes to the condensor coils (the radiator) and should be hot enough to burn your finger if you have enough freon. Also the larger of the two copper lines brings the freon back to the compressor from inside the cooler. It should be cold to the touch if you have proper freon pressure. If both of those two lines feel about the same temperature, either the compressor is not running or you have no freon. BE CAREFUL! There are electrical lines and moving fan blades near the compressor, and some of the tubing gets really hot.

Sep 22, 2010 | Beverage-Air MT17 Refrigerator Commercial

1 Answer

True GDM-12 - Unit runs, but won't cool below 60 degrees,


Is it very hot out side the unit.recharging may not hurt is it cleaned the lint could be trapping the radiator were the coolan goes through to cool down try cleanning underneath before recharging

Jul 26, 2010 | True GDM-12 Refrigerator Commercial

2 Answers

Air not cold enough to cool house


Make sure the outside fan is running. Also check the high side pressure, I assume the 70# is the low side pressure, so you can tell what the compressor is doing. If the fan and compressor are both working, make sure there is good airflow through outdoor coil and check that it is clean. Let me know what you find.

May 17, 2010 | Goodman CLJ24AR32 Air Conditioner

1 Answer

Compressor working, cooling coils hot, but unit won't cool below


When you say fully charged, did you weigh the refrigerant? These small systems cannot tolerate overcharging by even small amounts because it will result in overpressure on the suction side. If there's too much refrigerant you get hot coils and cool but not cold evaporator. I typically pump the refrigerant into a recovery tank and then weigh it back in to get exactly the amount on the mfg label.

Dec 12, 2009 | True 598-TSSU608ADA SandwichSalad Unit 155...

2 Answers

96 Tahoe no Cold Air


YOU NEED 28 PSI ON LOW SIDE AND ABOUT 190 ON HIGH SIDE.YOUR REFRIGERANT IS LOW THAT WHY COMPRESSOR CYCLING ON AND OFF.

Jul 22, 2009 | 1996 Chevrolet Tahoe

2 Answers

Beverage air cycling off/on


These units are not designed to run in temps much lower than 50 degrees. They have no winter controls and the freon pressures will take a nose dive when running in a cold ambient condition. The unit will not run well in a cold environment, compressor damage may result. :(

Dec 16, 2008 | Beverage-Air Beverage Air 2- Tap Unit...

2 Answers

Compressor shuts down when warm outside


make sure you provide shade for your unit. It may help keeping it cool.

Aug 27, 2008 | Honeywell Electronic Programmable...

Not finding what you are looking for?
Haier HSB03 Compact Refrigerator Logo

316 people viewed this question

Ask a Question

Usually answered in minutes!