Question about Hitachi Heating & Cooling

2 Answers

In 16.5 T Ductable Microcool AC , in out doorunit red led blinking 7 times , What is the problem? The phase Sequence is correct

Posted by on

Ad

2 Answers

  • Level 1:

    An expert who has achieved level 1.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 1 Answer

Remote hanset showing alaram code number 18 in11 tr ductable a/c.ther is no drain pump in unit

Posted on Dec 06, 2010

Ad
  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

What do u mean? i could not get,,

Posted on Apr 19, 2013

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My hitachi ac disply led 7 times blinking red light machine not working


These blinks [flashes] are fault indication (Error Codes). From the number of blinks occur at one time switch ON, you can get an idea about the faulty circuit section inside it. This will make repair easy. These are called blinking codes. Make sure about the exact number of blinking of the standby/power LED, by switching On & OFF the set, for at least two times. Count it carefully. If you wish to get some details, check the site linked here. It has details about blinking codes, and fault locating procedure, to many popular brand.
http://electro-medical.blogspot.com/

Jul 10, 2016 | Hitachi Televison & Video

2 Answers

Charger seems to have both red and green lites flashing at the same time no sequence and both batteries connected read 4.0 VDC, are these chargers repariable or throw aways


Your manual is here. The section on charging states, that green blinking means your battery is fully charged but blinking red means that your charger is faulty. I would say repairable.

1. Plug the female connector of the AC power cord (supplied) to the AC receptacle on the charger and plug in the male connector on the AC power cord into the wall outlet.

2. The On/Off LED indicator is blinking RED, this is abnormal. Unplug AC power cord from the on-board battery charger and wall outlet. Charger may need to be replaced. Contact an Invacare dealer or qualified technician.

3. When the On/Off LED indicator light is Off, charger is Off.

4. When the Charge LED indicator light is YELLOW, the batteries are charging.

5. When the Charge LED indicator light is solid GREEN, the batteries are fully charged (as their condition will allow).

6. When charging is complete, unplug the male connector of the AC power cord from the wall outlet and then unplug the female connector of the AC power cord from the AC receptacle on the charger.


http://www.invacare.com/doc_files/1125085.pdf

http://www.invacare.com/doc_files/1125085.pdf

Mar 24, 2016 | Invacare Pronto M51 Power Wheelchair

1 Answer

My Xenon high efficiency furnace has a red blinking led light that blinks 4 times and my furnace will not light. What could be the problem?


Gas furnace fault or error codes for common furnaces - Gray ...

www.grayfurnaceman.com/-ifc-failure-codes.html
Each color will also flash a specific number of times to signify a specific error. ... 4 redcolored flashes may be signaling that the "high-limit" switch might be open. ... 3 green colored flashes on your furnace has the same meaning as 2 green colored flashes. ....If a system problem occurs, a blinking LED shows a fault code.Missing: xenon

7 Tips and Tricks to repair your Furnace DIY - YouTube

? 13:25
https://www.youtube.com/watch?v=rAtcvPqUsBA
Dec 18, 2012 - Uploaded by JRESHOW .
Flash sequence codes 1 through 11 are as follows: LED will turn "on" ... 4 RED FLASHES: This indicates that the main limit switchhas opened ... This no-light condition occurred 3 times (2 retries) during .... My furnace trane xe80 is only flashing once my manual says something about flame being locked out ...Missing: xenon ‎efficiency

Nov 21, 2015 | Heating & Cooling

1 Answer

APC SILICON 40KW Ups.. on statrting ups it doesnt goes further to any screen display,Red ALaram LED is on(no blinking etc),. can any one guide?


apc silicon 40kw ups,1.check if input phases are complete.2.do a phase swap like changing the phase sequence and see if it will complain sequence error.3.after start-up u need to do a dc start-up,the dc bus is +360/-360vdc and after the dc bud is completed you need to press the green botten to power the inverter.if it doesnt do the dc start-up then go to the log and see what it complains about.write out the complain on the log and forward it to me.08082245266.engnr festus.

Oct 02, 2015 | APC Computers & Internet

1 Answer

My Viera TV: TH-P42ST30z seems to have shut down. When I turn it on the pilot light initially flashes green then starts a sequence of 7 red flashes, a gap, 7 more red flashes and this continues indefi


These blinks [flashes] are fault indication (Error Codes). From the number of blinks occur at one time switch ON, you can get an idea about the faulty circuit section inside it. This will make repair easy. These are called blinking codes. Make sure about the exact number of blinking of the standby/power LED, by switching On & OFF the set, for at least two times. Count it carefully. If you wish to get some details, check the site linked here. It has details about blinking codes, and fault locating procedure, to many popular brand TVs and other devices. http://electronicshelponline.blogspot.com/
Blinking codes details to many popular brand TVs are given. Surf the site with patience.

Oct 09, 2014 | Panasonic Televison & Video

1 Answer

Zanussi washing machine error codes 1 red flash and then 1 green flash


Hi there Yovanah:
Reds and greens on the start LED in a recurring sequence (unless you have an LCD display in which case the error code is displayed on screen).

Red flashes are the first digit in the error code, green the second. i.e. 5 reds, 2 green, then pause = E52. Which indicates a fault in the drive train...motor, motor capacitor, wiring, or pcb. Error codes are far from foolproof...on the contrary they can be directly misleading at times. But invalid error codes are almost always an indication of a defective pcb.

According with your code, E11 = Problems with water fill in wash phase (maximum 10 minutes for each fill phase).

Possible causes:
1: Tap closed
2: Mains water pressure insufficient
3: Solenoid valve
4: Hydraulic circuit of pressure switches
5: Pressure switches
6: Wiring 7: Main PCB

Hope this helps; also keep in mind that your feedback is important and I'll appreciate your time and consideration if you leave some testimonial comment about this answer.

Thank you for using Fixya, and have a nice day

Dec 19, 2011 | Washing Machines

2 Answers

My laptop screen is black and caps lock and scroll key are flashing


That is a security configuration on HP Laptops, depending on the way they blink is the problem your machine has.

Here is the web page where this info is posted, in case you need more info, hope this helps you to determain.

http://h10025.www1.hp.com/ewfrf/wc/document?docname=c01443366&lc=en&dlc=en&cc=uk&lang=en&rule=26781&product=3816592
This document pertains to HP Notebook PCs with the HP Unified Extensible Firmware Interface (UEFI) beginning in late-2008. On startup, you may see a blank screen. If the diagnostic utilities detect a specific problem with hardware components, the fan turns on, but the screen remains blank. To help identify the cause of the problem, various LED lights on the keyboard blink a series of codes. The diagnostic utilities use the LEDs near the Num Lock or Caps Lock keys to blink a series of error codes. At the end of the series the blinking stops. The pattern of blinks will occur any time you attempt to start the computer until the error is resolved. Battery power LED blinks The Battery power LED indicates the condition of the power supply. When starting the computer, or when the computer is in operation, use the chart to identify the power condition. Battery Power LED Component Tested Error Condition Battery power LED off, and Caps Lock/Num Lock off Battery or AC Adapter AC adapter not connected or failure

Battery low charge or failure Battery power LED blinking Battery Insufficient charge on the battery When new computer is used for first time, the white LED light for the AC power connector blinks. Battery is still in "Shipping Mode", the light continues to blink even when AC power is connected.

To resolve, turn off notebook, connect AC power and allow battery to charge for at least 30 minutes, then start computer. LEDs near Caps Lock and Number Lock keys blink when starting notebook The LED lights near the Caps Lock and Num Lock keys will blink if an error is detected during the start up process. The LEDs will blink a number of times in a sequence and then stop. The number of blinks in the sequence indicates what component caused an error when it was being tested during start up. If the LEDs stop blinking and the computer does not start, you can press the power button again to repeat the tests. Count the number of blinks, and use the chart to identify the error condition. Knowing the number of blinks is helpful when you contact an HP support agent for technical help. Caps Lock/Num Lock LED Component Tested Error Condition LEDs blink 1 time CPU CPU not functional LEDs blink 2 times BIOS BIOS corruption failure LEDs blink 3 times Memory Module error not functional LEDs blink 4 times Graphics Graphics controller not functional LEDs blink 5 times System board General system board failure LEDs blink 6 times BIOS BIOS authentication failure

Dec 01, 2011 | HP Computers & Internet

1 Answer

Power would not stay on red led flashes


I do not think we will get a response from person asking but you are correct, number of blinks indicates where problem is, the two most common are either a sequence of 3 blinks or one of 5 blinks.

Hard to help unless blink count is known.

SD TECH

Oct 23, 2011 | Panasonic PT-53WX42 53" Rear Projection...

1 Answer

KV-36XBR400 won't turn on, "standby/stero" light


You are correct. You are right about the power supply and replacing with led hdtv. You will be happy with a Samsung led. Time to upgrade.

Mar 04, 2011 | Sony KV-36XBR400 36" TV

1 Answer

42PF7220A/37 Blinking red led (7 times)


sounds like your tv in shut down mode why lamp needs 2 be replaced nominal cost 120 200$

Jul 25, 2009 | Philips 42PF7220A 42 in. Plasma Television

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

389 people viewed this question

Ask a Question

Usually answered in minutes!

Top Hitachi Heating & Cooling Experts

D. E. Hev

Level 3 Expert

1167 Answers

rugby prop

Level 3 Expert

580 Answers

yadayada
yadayada

Level 3 Expert

76051 Answers

Are you a Hitachi Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...