Question about Paragon 4001-00 24-hr Timer Control 120v Ac Cd101

1 Answer

I have a Paragon time switch type 4001-0 spst where can I buy extra on off tripers ??? I live in Winnipeg Manitoba . Is there a distributor or an agent here ??? please

Posted by on

1 Answer

I have a Paragon time - baf42df.jpg

The following website that shows Paragon parts > the chart shows you need the X2772 tripper
http://www.icca.invensys.com/paragon/parts_accessories.htm

1) Here's a website that sells X2772 for the unreasonable price of $16
http://www.gellert.com/index.php?action=item&id=2684&prevaction=pricelist

2) Here's a website that sells X2772 for the unreasonable price of $9 (marked down from $13 whow)
http://www.frontierlighting.com/product.jsp?part=49598&process=search

Up-vote if this information helped. Thanks for the feedback.

Posted on Oct 15, 2010

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have the Paragon 4001-00 timer. The timer seems to be working okay as far as time and trippers are tripping however it doesnt seem to be engaging our secutiy door lock for the night. Could the conrt


Does the manual override lever move back and forth as trippers pass? If NO, then trippers are bad
http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000
http://www.amazon.com/dp/B00441YVCO/?tag=waterheaterti-20

120 Volt timer.
When timer is ON, test across terminals 2 and 3 for 120 Volt
If 2 and 3 show 120 volt, then timer is delivering power on schedule. Look for loose connections. Loose wire nuts.
If 2 and 3 do not show 120 Volt, then timer has failed.
Suggest buy T101 as replacement for durability and generic replacement parts.
http://waterheatertimer.org/Buy-T100-series-timers.html

Crossover wiring from Paragon 4001-00 to Intermatic T101
Paragon 1 to Intermatic 1, Paragon 2 to Intermatic 2, paragon 3 to Intermatic A

Nov 05, 2014 | Paragon 4001-00 24-hr Timer Control 120v...

1 Answer

I need trippers for timer paragon 4001-00m


1) Paragon is no longer making X2772 trippers for the 4000 series timer.
Some places may still sell the X2772 tripper.
http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000

2) I saw X2772 trippers for $60 spring 2011. And the ad did not say the trippers were new.

3) Buy replacement T101 Intermatic timer for less than that.
Example at Amazon showing T101 indoor timer: For outdoor timer, buy T101R.
http://www.amazon.com/Intermatic-T101-Hour-Dial-Timer/dp/B00002N5FN

4) Crossover wiring from Paragon 4001-00 to Intermatic T101:
Paragon terminal 1 goes to Intermatic 1
Paragon terminal 2 goes to Intermatic 2
Paragon terminal 3 goes to Intermatic A
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

5) Add a comment for more help

6) Take a moment and rate answer for accuracy:
And take advantage of fixya expert assistance live.
For a price, expert works with you while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

Sep 14, 2011 | Hardware & Accessories

1 Answer

I need the on tripper for timer 4001-00


Google search: X2772 tripper

Thank you for including model number.
Paragon is no longer making 4000 series timer or the X2272 tripper.
Some places might still carry the tripper.
Resources:
http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000

Replacement timer for 4001-00 is Intermatic T101 timer:
Crossover wiring from 4001-00 to T101:
Paragon terminal 1 connects to Intermatic terminal 1
Paragon terminal 2 connects to Intermatic terminal 2
Paragon terminal 3 connects to Intermatic terminal A
Resource:
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

Take a moment and rate answer for accuracy:
And take advantage of fixya expert assistance live.
For a price, expert works with you while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

Sep 12, 2011 | Paragon 4001-00 24-hr Timer Control 120v...

1 Answer

Where can I find the timer triper set for a paragon 4001-0g


Open following link to identify timer and download manual
http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000

1) Paragon 4000 series uses X2772 tripper.

2) Internet search for tripper reveals some sources selling set of trippers for $50.
Paragon is no longer making timers or parts, except for defrost series timers.
4000 series is not a defrost timer, which explains high price for trippers.
Some sources might still have X2772 tripper at lower price.

3) Other companies are still manufacturing some Paragon timers for niche sales.
Certainly the Paragon line is still active although names and numbers will probably change over next few years.

4) I cannot specifically identify 4001-0g, and the 'g' suffix does not show in sell sheet
http://waterheatertimer.org/pdf/Paragon-4000-24hr-7000-7day.pdf

5) Replacement timer for 4001-00 is Intermatic T101
http://www.intermatic.com/customer%20service/competitive%20cross%20reference.aspx
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

6) New T101 from Amazon is $45.00 with free shipping
http://www.amazon.com/Intermatic-T101-Hour-Dial-Timer/dp/B00002N5FN

Add a comment for more free help.
Also take advantage of fixya expert assistance live.
For a price, expert works with you while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

Mar 23, 2011 | Paragon Hardware & Accessories

1 Answer

Not keeping correct time


You posted under Paragon 4001-00 120Volt SPST timer

1) If timer is not keeping correct time, generally you need to buy new clock motor.
However Paragon is no longer making timers and parts, except for defrost timers.
4001-00 is not defrost timer.
http://waterheatertimer.org/Paragon-timers-and-manuals.html#Paragon4000

2) You probably need to replace timer
Intermatic cross reference shows T101 timer is correct replacement.
http://www.intermatic.com/customer%20service/competitive%20cross%20reference.aspx

3) Amazon sells T101 for $43.
This price is a lot lower than trying to find somebody who has specific Paragon clock motor
http://www.amazon.com/Intermatic-T101-Hour-Dial-Timer/dp/B00002N5FN

4) Grainger and many other places sell T100 series replacement trippers and motors.
No worry about defunct product

5) Wiring for T101 appears below:
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

Cross-over wiring is as follows:
Paragon terminal 1 goes to T101 terminal 1
Paragon terminal 2 goes to T101 terminal 2
Paragon terminal 3 goes to T101 terminal A

Add a comment for more free help.
Also take advantage of fixya phone service.
For a price, expert speaks with you over phone while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

Jan 27, 2011 | Paragon 4001-00 24-hr Timer Control 120v...

1 Answer

NEED TO REPLACE A PARAGON MODEL 4001 24 HOUR TIME SWITCH WITH KNOCK OUT FOR CONDUIT CONNECTION ON TOP


Paragon 4001 is 120Volt SPST indoor timer.
http://waterheatertimer.org/Paragon-timers-and-manuals.html

I've never seen knock-outs for these timers on top because the timing mechanism is in the way.

Turn timer sideways, the timing mechanism still works.
geno_3245_77.jpg

geno_3245_78.jpgTimer flipped 90 degrees so KO is on top

Nov 18, 2010 | Paragon 4001-00 24-hr Timer Control 120v...

1 Answer

Need a programing Manual for a Paragon electronic timer, used for bells.


Paragon 4000 is a mechanical dial-type timer
You probably have Paragon EC4000 digital timer:
Single channel, NO, NC contacts, SPST with 5 poles or SPDT with 8 poles.

To identify your timer: Paragon 4000-7000 series

If you have EC4000, the following pdf files are helpful
EC4000 Sale sheet
EC4000 Programming

Sep 09, 2010 | Paragon 4001-00 24-hr Timer Control 120v...

1 Answer

HOw to disable the paragon 4001


4001 series timer is Paragon 120V mechanical timer.
http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000
1) To disable the timer, turn off circuit breaker and take wires off of the terminals. Put wire nut over each wire, and circuit will no longer operate.
2) If you want the circuit to operate without timer, then take wires off terminals. Twist black wires together and cover with wire nut. Twist white wires together and cover with wire nut.
3) Buy Intermatic T-101 timer to replace Paragon 4001 timer
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

Sep 13, 2009 | Paragon 4001-00 24-hr Timer Control 120v...

Not finding what you are looking for?
Paragon 4001-00 24-hr Timer Control 120v Ac Cd101 Logo

Related Topics:

1,313 people viewed this question

Ask a Question

Usually answered in minutes!

Top Paragon Hardware & Accessories Experts

Gene Haynes

Level 3 Expert

5089 Answers

Steve

Level 3 Expert

3287 Answers

jdthefixer

Level 3 Expert

744 Answers

Are you a Paragon Hardware and Accessory Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...