Question about Reddy Portable Forced Air Propane Heater w/ Variable Heat Ouput

1 Answer

I have a reddy heater model M100D, when I turn it on it runs for about 30 seconds and then the circuit breaker trips and shuts the heater off.

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 6,927 Answers

Check the fan motor to make sure there is no obstruction on the intake for the motor,and clean out the intake filter,and see if the fan motor spins freely by hand,if it is restricted in turning at all,the blower motor is bad,I have a pdf I can send you if you like,this will help you,it is a manual.If it will help,let me know,,by email,I can send it,,,roniecon@gmail.com

Posted on Oct 12, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

How to bypass the relay on a Reddy M100D


Best change the switch ,than bypass it .

Jan 03, 2017 | Reddy Heating & Cooling

2 Answers

Vogelzang kerosene heater will not ignite (no spark)


There is an igniter module and then the igniter electrodes (check the air gap) that produces the spark to start the fuel burning, both could be defective.

May 18, 2017 | Reddy Heater-30-55,000 BTU Variable

1 Answer

Heaters runs for a few minutes then shuts off.


was working fine refilled it and now it will run 5sec. and kick the breaker on it.It's an old 80's model 35,000 B.T.U. I cleand the photo eye with a cloth no change. Any solution's

Jan 29, 2010 | Reddy Heater-30-55,000 BTU Variable

1 Answer

Starts to run. Then pops CB in about 2 seconds. Ignition is OK. I think it momentarily lights off. REDDY HEATER made by DESA of Bowling Green, KY


Hi, when a circuit trips that quik, it indicates a dead short somewhere or even a motor drawing way to much amps for the breaker to handle. If this heater is a forced air type, try and find the wiring that controls the blower motor and disconnect it for just a few minutes to test it. You may want to do this with other control componants one at a time, just by- pass each one by unplugging or disconnecting each one and start it. If the breaker holds when you do this, you will then know which part is causing the breaker to trip. Keep me posted on your progress.
Shastalaker7

Jan 18, 2010 | Reddy R155D Utility Heater

1 Answer

Have a 155000 btu ready heater


It sounds like the unit is tripping the breaker because the breaker is not rated high enough to handle the heaters power usage! If its not that then it may very well be the thermostat needs replaced in unit!
Test at a friends house to see if its your system or the unit!

Dec 18, 2008 | Reddy Heater-30-55,000 BTU Variable

1 Answer

50K BTU Reddy Heater Trips Circuit Breaker


If the unit lights Check the photo cell this can be done with an ohm meter and good light. Should have continuity in light.

Jan 14, 2008 | Dayton E50 Heater

Not finding what you are looking for?
Reddy Portable Forced Air Propane Heater w/ Variable Heat Ouput Logo

Related Topics:

254 people viewed this question

Ask a Question

Usually answered in minutes!

Top Reddy Heating & Cooling Experts

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6924 Answers

Mack Baxter

Level 3 Expert

383 Answers

T bone 1963

Level 2 Expert

69 Answers

Are you a Reddy Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions