I have an old Bryant heat pump. I got a Hunter 44860 2 stage heat/2 stage cool but I am having problems with the wires. These is the Bryant set up (the wire colors do not match) Y G R O W1 W2 E C (these are the ones being used) The Hunter thermostat Y1 Y2 W2 G RH RC/R L C O E W1 B I need help so can some one please help me out here . Like I said the color of the wires do not match there are all different colors. Thank you in advance.

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Sergeant:

    An expert that has over 500 points.

  • Expert
  • 162 Answers

This should help you. You need to know if your thermostat is powered by the unit or independently and which way your reversing valve switches (I,m not sure on a Bryant, but probably Your old O wire goes to your new O terminal. They should pretty much match up, the new stat just has more options. Thermostat wiring

Posted on Jun 09, 2017

3 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

heatman101
  • 43501 Answers

SOURCE: im replacing my honeywell with a hunter 44110 the

Hi,
I hate to tell you this but that thermostat will not work with your system.
The system you have is a 2 stage system and the thermostat you got will only do one stage.
You will need to get a thermostat theat is compatible with stage heating and cooling.
The W1 is the first stage heating, the W2 is second heating. The same is true for Y1 and Y2 on cooling
You could double them up, but it would defeat the encomoy reasons for having a 2 stage unit.
Wish I could give you better news..

I hope that this will help you to solve your problem!

Thanks for using Fixya!!

Heatman101

Posted on Dec 05, 2009

  • 98 Answers

SOURCE: The Honeywell LR69071 (old) has 7 wires connected

Wiring on the old one, "X", probably a brown wire will not be used on the new stat. If it's a blue wire, this may be your common. "E" and "W2" probably wired together with a white wire, this controls electric heat. "R" with a red wire, this is 24 volt power. "O" is an orange wire, this is the reversing valve. "Y" is a yellow wire, this is the contactor. "G" is a green wire, this is the blower. This pretty accurate? On the new stat, the jumper should be connecting "RH" to "RC/R", leave it in and wire the "R" from your old one to either terminal. White from the old one will go to the "E" of the new one. If your electric heat doesn't work after the install, you may need to jumper the "W1" and "W2" with the "E". "O" wires to "O". "Y" from the old one wires to the "Y1" of the new. "G" wires to "G". "C" on the new one is common. Usually a blue wire goes here. If "X" on the old one was blue, plug it into the "C". If it was brown, I'd suggest not using a common, and installing batteries. Hope this helps.

Posted on May 09, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

How do I set my hunter thermostat so when the heat pump comes on, how to set so the thermostat and heat strips from the heat pump sinc with each other. The model number is 44860


call a service tech, this sounds complicated. To avoid using too much energy or burning down your life savings in heating bills, a certain sequence should be followed when the thermostat operates. The actual sequence will differ depending on what equipment you have available to control, as well as your location and heating and cooling loads. The money you could save by having it done right the first time will quickly pay for a service call, then keep on saving you money after that.
25457614-epwetmasq2n0wnrof1fw5po3-5-0.jpg

Feb 21, 2015 | Hunter 44860 H Univ. Touchscreen...

1 Answer

Hunter 44272 Not turning on heater


i am recommending you try again to call to the service man. The reason is simple you change it and they have all the wiring diagram for do it quickly. Get support via ONLINE or chat or phone.

Maybe you have some wrong wires connect
God bless you

Oct 08, 2012 | Hunter 44272 5-Minute 5-1-1 Day...

1 Answer

I have 7 wires, how do I wire it Red Green White Black Yellow Orange Blue


Conventional heating, air conditioning and heat pump thermostat wiring labels, wire color codes and the corresponding function description: Terminal
Designation
Wire
Color
Function
Description
Rh Red 24 Volt Hot for Heating Rc Red 24 Volt Hot for Cooling Y1 Yellow First Stage Cooling Y2 Blue Second Stage Cooling G Green
Grey * Energizes Indoor Fan W1 White Energizes First Stage Heat W2 Black Energizes Second Stage Heat O Orange Heat Pump
Reversing Valve
Energized In Cooling B Brown Heat Pump
Reversing Valve
Energized In Heating C Brown** 24 Volt Neutral
(Common) leg

Hope this helps
Tom Miller
Broadcast Eng

Sep 07, 2011 | Hunter Fan Company 5/1/1 Programmable...

2 Answers

I am trouble shooting a Bryant Hi-bred system that uses an air cooled heat pump with high efficiency gas furnace for backup and low ambient operation. How does the system decide whether to use the air...


Your t-stat should be set up so that the furnace is the second stage heat and also emergency heat. First stage (heat Pump comes on) sometimes they use Time to start 2nd stage, sometimes they use outdoor temp and this all bepends how bryant has set it up, without a model # I cannot tell you but send it and i will look in somebooks i have to tell you.

Mar 01, 2011 | Bryant Heating & Cooling

1 Answer

Reversing valve wire kills either heat or AC


Your solution is throw that Hunter tsat away and get a good one. You need one with 2 stage heat 1 stage cool heat pump tstat. Heat pump tsta has w,y,o,g,w,rnad w2. Don,t buy one without this one it. I have been in this business 45 years and people are always getting sold the wrong tstat at Lowe or Home Depot. Those guys dont know jack about Tstats. Keep in touch Rus GOOD LUCK. Get the right tstat follow the letter on wiring and you wont have any problem.

Nov 19, 2009 | Heating & Cooling

1 Answer

Is the Bryant 661CJ030-A heat pump single- or multi-stage?


Single stage heat pump. But you must have a two stage tstat for backup electric heat. You single stage cool two stage heat. The second stage brings on the electric heat in case the heat pump can not keep up. Wiring goes r y w1 on most heat pump tstats are switchover valve or o terminal. W2 second stage heat or emergency heat. g is fan c is common terminal.Rus

Nov 11, 2009 | Bryant 463AAC008BA Air Conditioner

1 Answer

Hunter thermastat, model 44860 not working


Is the compressor running? is the outside unit clean and free from debris? does this unit work in the heating mode during the winter, and is it still capable of that now.

Jun 01, 2009 | Ruud UAMB Air Conditioner

4 Answers

44860 thermostat won't activate in heat mode


I had the same set and problem. I had a RC wire which is the power to the AC. But didn't have an RH wire which is the power for the heat. To fix this just use the jumper wire and insert it in with the RC wire and hook it up to the RH. Fixed my problem.

Oct 20, 2008 | Hunter Fan Company 5/1/1 Programmable...

Not finding what you are looking for?
Hunter Fan Company 5/1/1 Programmable Thermostat Logo

Related Topics:

239 people viewed this question

Ask a Question

Usually answered in minutes!

Top Hunter Dryers Experts

Paul Bade

Level 3 Expert

1536 Answers

yadayada
yadayada

Level 3 Expert

75797 Answers

Brandon Berry
Brandon Berry

Level 2 Expert

407 Answers

Are you a Hunter Dryer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...