Question about Heating & Cooling

1 Answer

I have a tempstar central heat and air unit and i need a wire diagram for a model pa5548aka4.

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

My tempstar central a/c unit will not get above 80 degrees during the day, the charge is fine so we are told, we noticed that the coils and fins are filthy and we have done everything to try to clean it out with a fin tool, fin brush and coil spray and there is still junk in it. we cannot remove it and clean it outside as i would love to do; its too involved to do that so we are trying to clean it in its place we have also sprayed it with a water hose and an air compressor, although it helped some i can still see gunk in it. my coils are on the bottom end of my inside unit. any advice on what else can be done to clean it well? my unit is only 7 years old. also i was told that i need to set my blower to high speed how do i do this and where is it located? thanks for any help or advice. my e-mail is map41269@yahoo.com

Posted on Jul 13, 2011

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Tempstar Performance Series Heat Pump


damaged capacitor most likely. open the unit and see if theres any liquid spilling from the capacitor.

Aug 09, 2013 | Heating & Cooling

2 Answers

Heat pump will not turn on


I would call an expert, testing needs to be done, but based on what I have seen it may be the control board of the heat pump is defective.

Mar 24, 2017 | Heating & Cooling

1 Answer

I have a tempstar gas pack,when I cut the heat on the heat fires up, but the blower doesn't come on. I changed out the contactor and the capacitor,and had the blower moter checked and it is fine. I've been...


Does your fan work in auto. If not you may have a wiring problem. Be glad to talk to you and help. Call me at 251-540-2730 and I will give you a hand. Rus

Nov 28, 2009 | Ruud Central System Air Conditioner

1 Answer

Central air unit/ Lux500 thermostat


There is usually an overflow tray which has a shutoff valve when the tray is about to overflow water into your house. It is not located outside on your unit but inside where ever the condenser unit is. IF that tray is full of water, your unit will not turn on until it is emptied. Then you need to find out why the tray isn't draining...do you have a blocked drain pipe?

Jun 21, 2009 | Jackson 25 in. TempStar HH70 Free-standing...

2 Answers

Wiring Diagram for a Emerson Motor in a Tempstar Central A/C


EMERSON 1/4 HP MOTOR 5 WIRES BLACK BLUE BROWN WHITE RED LOST MY DIAGRAM 115V1075 RPM 3 SPD HOW DO I WIRE IT TO THE COMPRESSOR

Sep 26, 2008 | Emerson Heating & Cooling

1 Answer

Ac heat carrier thermastat model no.hh01ad042


GOto the iside unit itself. and remove the door and look for a terminial strip that the thermostat wires from the thermostat connects to and write down the colors wires and the letters they're connected to and connect the same to the thermostat .... they should be... r--red=power w-white=heat y--yellow=cool g-- green=fan! See which wires/ colors they're not using and bend back! Thank-you-very-much!

Aug 31, 2008 | Heating & Cooling

1 Answer

TempStar 10 AC


visit www.gotempstar.com for the schematic on this unit. Coincidentally, your air handler unit should not draw 15.6 amps with an additional 40 for the heater.

Jan 07, 2008 | Dishwashers

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

191 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2463 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...