Question about HP Compaq T1000 XR (217858001) UPS System

1 Answer

I have a HP Compaq T1000 XR UPS is the cooling fan suppose to run all the time. Thanks Dean

Posted by on

Ad

1 Answer

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer
Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
New users get 2 Free calls (no credit card required) and instant help on almost anything you can think of (from cars to computers, appliances, handyman, and even pets).
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

What is the proper rpm for the 80 mm cooling fan and also the 90 mm cooling fan for the HP Amd Athelon II? I am trying to diagnose this with a monitoring software package. It tells me what the rpms are...


Trace the power wire from the fan back to where it connects to the motherboard. Below where the wire is connected it should be labled on the board what fan it is.

Apr 22, 2011 | HP Compaq Fan Assembly

1 Answer

The HP T100XR comes with 9ah batteries. They seem to be at the end of their life as I get little to no backup when the power is interrupted. I have a pair of 8ah batteries and was wondering if they can be...


Im like Mr., UPS, used to do 911 centers, vast huge banks of batteries, 50 or more.
the batteries, in UPS can be wired in different ways,
series, parallel and mix.
im not going to attempt to read your manual for you.
The charger wont care, its still lead and acid.
the charger watches voltages and does SOC tests to charge them.
i say ok but do not mix them. 8 and 9ah.
the internal resistance is different
all that really is different is the lead plate sizes.
9ah has later plate area....
only charge time and run times change
we also used a very expensive , battery internal resistance meter
that tells us that (cell(res)) , and can measure life, this way ,
we do that tests every 3 months and using the markers charts
we see ho much capacity is lost/ aged..
and replace them at 50% end of life point.
that is how we kept from having down time.

my guess 2 batteries in series, 24vdc, , that is how its strapped?
it will work.

Oct 23, 2017 | HP Compaq T1000 XR (217858001) UPS System

1 Answer

Cooling fan (not heatsink fan) does not run


Well i depends on what motherboard have you got. It must have a setting to tell it on the sensor of the motherboard. Check the BiosSettings

May 02, 2010 | HP Compaq (216472001) CPU Fan

1 Answer

My audio is not working.


Go to the official website of the hardware manufacturer and look for the drivers. These drivers are generally free of cost.

Jan 14, 2010 | HP 204404-001 - Compaq/HP Smart UPS R1500...

1 Answer

Need program for my UPS hp t2200 xr on debian system, is there anyone out there?


You can find here a very good software for UPS under Linux OS:

http://www.networkupstools.org/compat/stable.html

Check if your UPS is compatible...

Oct 19, 2009 | HP Compaq T2200 XR UPS System

1 Answer

How to install battry in prr200 deltec ups


They are 12v 22AH SLA batteries. They are wired in series. The neg runs to the board, the two positive wires run to the fuses at the side of the cabinet.
-Phil

Aug 28, 2009 | Compaq UPS T2200 XR UPS System

1 Answer

Compaq UPS R3000 XR Comms cable


Hi Jon,
so we could use this link it as a solution for your problem?
http://h20000.www2.hp.com/bizsupport/TechSupport/Home.jsp?lang=en&cc=us&prodTypeId=3447589&prodSeriesId=255222&lang=en&cc=us
Kind regards,
noris017

Feb 25, 2009 | Compaq UPS R3000 XR UPS System

1 Answer

Hp 3000


Cape town Mexico, Canada ? hehehe
Cape town where ?

May 07, 2008 | HP 3000 XR (j4367a) UPS System

2 Answers

I have a Compaq T2200XR UPS, the battery is out, it shows a battery with and X, my question is, Is it going to shut down or it will keep passing truw power with no battery until I get a new one in 2 or 3...


Wait till you get the new batteries........, then swapped them out.

The answer is yes, until you have a blackout. oops.

You have something..... so

By the way give me the battery information and I will send you batteries. Be happy to sell them to you. I may quote yoiu a better price then anywhere else.
Call me 727-823-6100
Good luck.

Dec 03, 2007 | Compaq UPS T2200 XR UPS System

Not finding what you are looking for?
Computers & Internet Logo

Related Topics:

503 people viewed this question

Ask a Question

Usually answered in minutes!

Top HP Computers & Internet Experts

Les Dickinson
Les Dickinson

Level 3 Expert

18402 Answers

Doctor PC
Doctor PC

Level 3 Expert

7733 Answers

Donald DCruz
Donald DCruz

Level 3 Expert

17130 Answers

Are you a HP Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...