Open Question

For LG split ac,gas filling to improve cooling,wheather sealed gas kit of the LG company will be available? if so, its nominclature please

Posted by on

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 1 Answer

SOURCE: Unable to locate the product model LG LSA5NW2VF1 for room AC

know u can go to lg website lgindia,com

Posted on Mar 13, 2009

louislevel_2
  • 374 Answers

SOURCE: Lg 2hp split air condition needs original refill gas

hi! there,
well! there several factor to be consider in
insufficient cooling effect,
1. under charge, low charge of freon
how to detect: Check oprerating current
using clamp ammeter ,
clamp on one line and
take reading compare
this to rated current on
manuals if below
your system is under
charge,recharge
freon 22 ,if same is good

check also on sight
glass located on hi side
if bubbles appear your
system is under charge
irecharge if clear still
good.

Freon 22 and others are refrigerant gas and easily evaporate when they escape on athmospheric pressure.they are dagerous to our athmosphere if they expose,they destroy our stratosphere that filter sunlight coming to earth the radio active of sun cannot enter or block by stratosphere if this destroy radio active affect our mother earth.
so in charging freon,they should not escape or leak in our athmosphere take all necessary precaution,there is international law about freon leaking on air,try to update on this issue.



2. evaporator coil and blower should always maintain in obstruction and paricles blocking the fin.if the ice is developed on eveporator this mean evaporator is dirty need to be clean also with fan and blower.they cannot blow air sufficiently due to ice solidified on fin to block air passage.also, on condenser tube fin don let to distored rejection of heat sufficienly help good evaporation of freon .

if fan and blower has insufficient in blowing of air, change bearing, perfomance
will improve in full effeciency.
so cheers and have a nice day to london
guys thank's

Posted on Apr 03, 2009

  • 234 Answers

SOURCE: split ac not cooling

I would check the drain to see if it is stop up.Next check to see if the unit inside is freezing up.If it is check to see if fan is running and if fan is running the you proable have a freon leak. Low charge on freon will make it freeze up and the fan not running also.

Posted on Apr 07, 2009

zohail
  • 1223 Answers

SOURCE: split ac not cooling the room

Gas has leaked from inner or outer unit kindly get it checked by service men they will find the leak and charge the gas again normally after some time it gets rusty inside as water is involved and got leak

no problem get it repaired not expensive

pls rate me well !
Regards

Posted on Jul 14, 2009

  • 81 Answers

SOURCE: LG split AC keeps displaying CO and wont't turn off with remote.

The "CO" indicates cleaning operation and can be switched of via remote button under flap, labelled AUTO CLEAN.
Mat

Posted on Jul 20, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

F8 dispaly error in blue star split ac


hello,
i also find this problem in my bluestar ac then i callled authorized service man . then he did these steps :-
1> Replace the sensore ( you will find inside the ac wich will be red or brown in color)
2> then check wheather the wire is in good condition or not means
is it working or not.
3> then clean the outdoor unit filters and coils,
4> and check the proper supply of electricity..

Mar 15, 2013 | LG LS-L1210CL Mini Split Air Conditioner

1 Answer

I have purchased one Samsung Split 1.5 ton AC from Vijay Sales ? Baner Road branch on 19th Sept 2010 by paying cash payment. The same ac was delivered to me on 21st Sept 2010. The Samsung Authorised...


You have a LEAK from installation that must be found & repaired before any more GAS is added to the system.Then it will normaly need a little gas every 3 years.

Sep 29, 2010 | Samsung Heating & Cooling

1 Answer

LM-2430C2L 24000 BTU Cooling Only Dual Zone Mini Split Air Conditioner: Does LG makes AC which can cater two rooms at time...


Yes they Do they are called Dual Zone Units. At http://www.paylessminisplit.com they are very helpful if you call them they can answer alot of questions about many brands of mini split air conditioners.

May 16, 2010 | LG LM-2430C2L Cool Mini Split Air...

1 Answer

What is the presure of the LG WINDOW AC compresser .we perchesed it in2005.last year we found that it was not cooling so we called AC man he said that gas has to be fill ,he did it .again this year also we...


If he is having to continually recharge the unit, the unit has a leak in it. The leak would have to be located before the cost of repair could be determined.

Feb 24, 2010 | LG Heat cool Window Air Conditioner

1 Answer

Best split ac 1.5 ton


I think you just have a faulty unit. Most of the mid wall split units have similar components and there are only cosmetic differences. Lg is strangely enough a good aircon. Personally i like Samsung .(Spares are easily available). You should concider who the best after sales service supplier is and go that way. (As stated, most units are similar in my oppinion.)

Sep 21, 2009 | LG Heating & Cooling

2 Answers

Split ac not cooling the room.ac temparature remains at 27 degree after ac runs for about 4 hours.please solve this


Gas has leaked from inner or outer unit kindly get it checked by service men they will find the leak and charge the gas again normally after some time it gets rusty inside as water is involved and got leak

no problem get it repaired not expensive

pls rate me well !
Regards

Jul 14, 2009 | LG LS092CE Split System Air Conditioner

1 Answer

Ice formation in the indoor unit


you need to have the unit checked for the amount of freon in the system this must be done with a gauge set the freon amount is obviously incorrect
also the a-frame evaporator must be sealed in the furnace cabinet

May 28, 2009 | LG Heat cool Window Air Conditioner

2 Answers

AC Compressor


Does not sound right to me.My guess after doing what every he was doing he probably installed a start capacitor or repaired a burnt wrie, got the compressor running and charged for a lot of guess work. Just guessing.

Jan 04, 2008 | LG Heat cool Window Air Conditioner

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

194 people viewed this question

Ask a Question

Usually answered in minutes!

Top LG Heating & Cooling Experts

Donni Steen

Level 3 Expert

659 Answers

Tim Whalen

Level 3 Expert

3072 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Are you a LG Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...