Thermal fuse location on a 110.9597590110 gas dryer

1 Answer

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

  • Master 1,554 Answers
  • Posted on Sep 30, 2010
Anonymous
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

Joined: Jan 30, 2010
Answers
1554
Questions
0
Helped
612185
Points
4917

The model number of your machine doesn't seem to exist but the thermal fuse, whether dryer is electric or gas, is always located on the blower housing together with the thermistor or cycling thermostat depending on the model of the dryer. The blower housing is located at the rear of the dryer if the lint filter of you dryer is located on top of the cabinet and can be accessed by removing the rear panel.
thermal fuse location on a - 68f5c8b.jpg

The blower housing is located on the front right bottom of the dryer if the lint filter is located on the door. It can be accessed by removing the kick panel.

Kick Panel Removal

Once the kick panel is removed, remove the lint chute to expose the blower housing and the thermal fuse.
b893774.jpg

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

3helpful
1answer

How do i replace the thermal fuse

Hello there
Unplug your dryer from its electrical outlet. make sure that all electricity has been disconnected from your dryer before moving on

turn off the gas valve that supplies gas to your dryer. Remove the gas flex line at the shut-off valve using an adjustable wrench.


Remove your dryer's back panel. take out the screws on the back of the dryer and the panel will come free. set the panel and screws aside until you are ready to replace them.


locate the thermal fuse between the dryer's blower housing and exhaust. the thermal fuse looks like a white plastic strip with two connected wires.


unplug the wires connected to the thermal fuse.


remove the screw that secures the thermal fuse to your dryer. set the screw aside and discard the broken thermal fuse.


replace the thermal fuse screw to attach the new replacement thermal fuse to your dryer.


reconnect the wires to the thermal fuse.
2helpful
1answer

Dryer will not heat gas

Check the following areas to combat this issue. the most common problem spot will be a blown Thermal fuse.


1. Gas valve coils
Igniter glows, then shuts off without igniting gas - the problem is probably with defective coils (black, located on top of the gas valve). It is recommended to replace all coils (usually two or three) if found defective.

Note: Sometimes the whole gas valve may be defective, thus not letting the gas out. However, this problem is not common.

2. Thermal fuse
Most dryers have a thermal fuse, which burns out when the dryer overheats, in which case the dryer will either not run at all or stop heating. The fuse is usually located on the vent duct, inside the dryer. A blown fuse will show no continuity when measured with a meter. Before replacing the fuse, make sure the blower wheel is not broken or clogged, and there is nothing blocking the venting.

Note: It is recommended by most dryer manufacturers to replace a hi-limit thermostat when replacing a thermal fuse.

3. Igniter
Igniter may burn out or break. Replace the igniter if found defective.

Note: Igniters are very fragile and break easily. It is recommended to handle the igniter only touching the ceramic part of it (usually white in color).

4. Flame sensor (or radiant heat sensor)
Replace the sensor (located near the igniter) if found defective.

6helpful
1answer

Kenmore gas dryer wont heat up

Check the following areas to combat this issue. the most common problem spot will be a blown Thermal fuse.


1. Gas valve coils
Igniter glows, then shuts off without igniting gas - the problem is probably with defective coils (black, located on top of the gas valve). It is recommended to replace all coils (usually two or three) if found defective.

Note: Sometimes the whole gas valve may be defective, thus not letting the gas out. However, this problem is not common.

2. Thermal fuse
Most dryers have a thermal fuse, which burns out when the dryer overheats, in which case the dryer will either not run at all or stop heating. The fuse is usually located on the vent duct, inside the dryer. A blown fuse will show no continuity when measured with a meter. Before replacing the fuse, make sure the blower wheel is not broken or clogged, and there is nothing blocking the venting.

Note: It is recommended by most dryer manufacturers to replace a hi-limit thermostat when replacing a thermal fuse.

3. Igniter
Igniter may burn out or break. Replace the igniter if found defective.

Note: Igniters are very fragile and break easily. It is recommended to handle the igniter only touching the ceramic part of it (usually white in color).

4. Flame sensor (or radiant heat sensor)
Replace the sensor (located near the igniter) if found defective.

0helpful
1answer

Gas dryer does not heat up. Gas is on and the

Check the following areas to combat this issue. the most common problem spot will be a blown Thermal fuse.


1. Gas valve coils
Igniter glows, then shuts off without igniting gas - the problem is probably with defective coils (black, located on top of the gas valve). It is recommended to replace all coils (usually two or three) if found defective.

Note: Sometimes the whole gas valve may be defective, thus not letting the gas out. However, this problem is not common.

2. Thermal fuse
Most dryers have a thermal fuse, which burns out when the dryer overheats, in which case the dryer will either not run at all or stop heating. The fuse is usually located on the vent duct, inside the dryer. A blown fuse will show no continuity when measured with a meter. Before replacing the fuse, make sure the blower wheel is not broken or clogged, and there is nothing blocking the venting.

Note: It is recommended by most dryer manufacturers to replace a hi-limit thermostat when replacing a thermal fuse.

3. Igniter
Igniter may burn out or break. Replace the igniter if found defective.

Note: Igniters are very fragile and break easily. It is recommended to handle the igniter only touching the ceramic part of it (usually white in color).

4. Flame sensor (or radiant heat sensor)
Replace the sensor (located near the igniter) if found defective.

Aug 01, 2009 • Dryers
2helpful
1answer

Dryer runs, but does not heat

Check the following areas to combat this issue. the most common problem spot will be a blown Thermal fuse.


1. Gas valve coils
Igniter glows, then shuts off without igniting gas - the problem is probably with defective coils (black, located on top of the gas valve). It is recommended to replace all coils (usually two or three) if found defective.

Note: Sometimes the whole gas valve may be defective, thus not letting the gas out. However, this problem is not common.

2. Thermal fuse
Most dryers have a thermal fuse, which burns out when the dryer overheats, in which case the dryer will either not run at all or stop heating. The fuse is usually located on the vent duct, inside the dryer. A blown fuse will show no continuity when measured with a meter. Before replacing the fuse, make sure the blower wheel is not broken or clogged, and there is nothing blocking the venting.

Note: It is recommended by most dryer manufacturers to replace a hi-limit thermostat when replacing a thermal fuse.

3. Igniter
Igniter may burn out or break. Replace the igniter if found defective.

Note: Igniters are very fragile and break easily. It is recommended to handle the igniter only touching the ceramic part of it (usually white in color).

4. Flame sensor (or radiant heat sensor)
Replace the sensor (located near the igniter) if found defective.

3helpful
2answers

Location of the thermal fuse on the kenmore gas dryer 80

It is mounted on the rear of the dryer on the blower housing. f8cdc70.jpg

If you need further help, reach me via phone at https://www.6ya.com/expert/dan_73bbd84fe1d95b61

Feb 03, 2009 • Dryers
0helpful
1answer

Location of thermal fuse on whirlpool estate gas dryer

if this is a gas dryer and the ignitor is working the thermal fuse is fine.need more info .dose the valve coils make any clicking noisecheck with ohm meter to see if coils open/also is gas on
Dec 31, 2008 • Dryers
0helpful
2answers

Thermal fuse

the thermal fuse is located on the heater box,the main fuse is located on the blower box,let me know-mike
0helpful
1answer

Thermal fuse

hi. thanks for the question. the thermal fuse is located in the dryer, on the air duct, small piece with 2 wires to it. replace . also clean venting, and inside the dryer.thanks the appliance doc
Oct 05, 2008 • Dryers
0helpful
3answers

Thermal fuse location

the thermal is on the heater box on the right side it has two white wires going to it
you need to remove the high limit stat and bracket and the heating element to get to the safety stat
Not finding what you are looking for?

299 views

Ask a Question

Usually answered in minutes!

Top Kenmore Dryers Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Brad Brown

Level 3 Expert

19187 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Kenmore Dryer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...