Question about Samsung Heating & Cooling

1 Answer

Sensor in my Samsung Split Heat/AC indoor unit does not detect the remote control. Worked ok for 4 years. Tried a new remote and still didn't work. I can turn the unit on and off from the unit but need to use the remote for certain functions. Can't find anyone to service it. Thanks! Samsung AQ12ABMCF

Posted by on

  • 3 more comments 
  • suwilson2 May 24, 2008

    Have tried new batteries and even a new remote. Didn't help. Guess I need to call someone to service the unit?

  • suwilson2 May 24, 2008

    Thanks. I have the service manual but it was of no help.

  • suwilson2 May 24, 2008

    Would try to fix it myself if it was an easy fix. Does the sensor in the unit run by battery or it is part of the electical system? If it is I would need to call for service.

  • suwilson2 May 24, 2008

    Thanks. I'll try the online form to find someone to service it. The online support didn't work. They don't recognize the model # for ac units. My guess is that they've dumped them. Just my luck!
    Thanks again.

  • Anonymous Mar 27, 2014

    remote control for Ambiance ac INDOOR UNIT AS12115V13H/I

×

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Samsung Master
  • 13,433 Answers

The receaver is most likely broken?

Posted on May 24, 2008

×

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

What is the corrective action for error code 46?


Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor

Jun 23, 2015 | LG Art Cool LA240HSV 22,000 BTU SingZone...

1 Answer

I have samsung split ac 1.5 ton 2.5 years old when am switch on the ac the indoor unit is working when it tires to on the out door unit after 3 minute delay suddenly the ac is restarting but the out d


Make sure all of the pressure switches are closed on the low voltage control circuit on the outdoor unit. If any are stuck open, the compressor will not kick on. Or just push the compressor contactor in with an insulated screwdriver to ensure the compressor does actually work.

Dec 28, 2014 | Samsung Heating & Cooling

1 Answer

Remote control required for airconditioner


Not too many units only work with remote control...try using Bing or Google to find your problem and solution to the answers that you seek.

May 18, 2013 | Heating & Cooling

2 Answers

Have an LG split system air conditioner. No way to turn it on or off on system. Remote only and it is not working. Did this a week ago and changed batteries, took a while before new batteries worked as...


Before buying new one, try with this step. Remove batteries from your remote and reset it after 5 minutes. And also remove DC wires plugged to indoor sensor display, and after 5 minutes re set it again. Now start your unit. Sometimes it will work out. Thanks.

Feb 02, 2011 | LG LSC121PMA Split System Air Conditioner

2 Answers

My sairon split system ac unit does nothing and comes up with e3 on the display


if split ac display shows e3 what is the solution for that problem

Dec 10, 2010 | Heating & Cooling

1 Answer

When we turn on our split AC, outside unit is not turning ON


The blinking light is because the unit is waiting for the outdoor unit to come on. If in heating mode, the indoor fan will not run before enough pressure and therefore heat has built up. You should check that the indoor air return sensor is not faulty and therefore preventing the outdoor unit from coming on.

Nov 15, 2009 | Amcor NanoMax A12000E Portable Air...

1 Answer

I hve purchased panasonic split a.c. b4 1 month only, mi remote senson is not working properly, i mean when i push mi remote button, its effect does not come in mi indoor unit sensor.


Ok, there are a few things to check.
1. Batteries on the remote.
2. Reset remote - switch sometimes in battery compartment and sometimes behind cover, need to press with sharp nib or pen.
3. Check on indoor unit that remote has been selected on the manual/auto switch, located under the cover on right hand side.
4. Remove indoor unit cover complete, (three screws behind the louvers and one on the electrical cover). Change the remote sensor board.

Mar 10, 2009 | Panasonic Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

379 people viewed this question

Ask a Question

Usually answered in minutes!

Top Samsung Heating & Cooling Experts

Nyte_Ryder

Level 2 Expert

93 Answers

Ezewudo Onyekachi
Ezewudo Onyekachi

Level 3 Expert

406 Answers

yadayada
yadayada

Level 3 Expert

70347 Answers

Are you a Samsung Heating and Cooling Expert? Answer questions, earn points and help others