Question about Teledyne Laars Laars Lite 2 Pool Heater 125,000 Btu / Propane Gas

1 Answer

I have a Laarslite TELEDYNE Laars LLG type and the main valve never turns on. I checked the switch/potentiometer and they are perfectly fine. I can not find any power source. where is the power to feed the valve and the entire electronic board is coming from ? It seems that all the presure switches and thermo disk are fine but I still can find any votage.

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Top Expert:

    An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Teledyne Laars Master
  • 6,394 Answers

On a LLG the pilot is the voltage 500 millivolts to you with a meter its 2000 on ohms check and clean all connections especially the gas valve check the hi limits sometimes they get oxidized

Posted on Jan 14, 2016

Ad

2 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
  • 990 Answers

SOURCE: looking for the manual for laarslite teledyne

I thought I had that address for you. I must have lost it last time I cleaned up my computer.
Laars is now part of the Jandy Corp. I'm sure that is where I found it last I needed it. It is a good place to start

Posted on Jul 07, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Teledyne Laars Series 2 pool heater just clicks when the heater thermostat is turned on


check to see if voltage on both sides of pressure switch if so see if ignitor is lighting if ok check to see if voltage to gas valve should be 24 volts on each if no voltage check transformer also

Jul 10, 2012 | Teledyne Laars Laars Lx Nat Gas Pool...

1 Answer

Want to convert lp gas to natural gas laarslite llg250


not adviseable years ago they would sell you different orfices and change the gas valve setting but too much liability involved LP runs hotter so they had smaller orfices unsafe

Mar 21, 2012 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

Larrs lite llg natural gas heater - the only way i can light the pilot is to remove the valve knob and push the valve pin in manually - that lights the pilot everytime but when the pin is released, the...


This is a problem with the thermo-pile. Yoiu need a 750 millivolt general replacement thermopile. You can purchase at your local HV AC supply store. Should cost about $45

Jan 23, 2011 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

Looking for the manual for laarslite teledyne


I thought I had that address for you. I must have lost it last time I cleaned up my computer.
Laars is now part of the Jandy Corp. I'm sure that is where I found it last I needed it. It is a good place to start

Jul 07, 2010 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

I have a teledyne laars lite 2, it fires up fine but the flames are excessive and go outwards towards the wires, any ideas


It would seem that this unit has had a conversion done from Nat to LPG or visa versa..the main gas valve and burners need to be adjusted
http://www.laarsman.co.uk

Miles

May 03, 2010 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

Pool heater will not stay lit


Problem with the thermocoupler its not producing a minivolt of 250 plus that is needed to open the main gas valve

http://www.laarsman.co.uk

Miles

Apr 05, 2010 | Teledyne Laars Laars Lite 2 Pool Heater...

Not finding what you are looking for?
Teledyne Laars Laars Lite 2 Pool Heater 125,000 Btu / Propane Gas  Logo

Related Topics:

65 people viewed this question

Ask a Question

Usually answered in minutes!

Top Teledyne Laars Pool & Spa Experts

Paul Carew

Level 3 Expert

2597 Answers

Jay Finke
Jay Finke

Level 3 Expert

1363 Answers

Bill Jordan

Level 2 Expert

372 Answers

Are you a Teledyne Laars Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...