Toshiba Satellite A135-S4467 Notebook Logo

Related Topics:

Posted on Sep 13, 2010
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

Unit wont display....fan still turns on... - Toshiba Satellite A135-S4467 Notebook

1 Answer

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Master 2,567 Answers
  • Posted on Sep 18, 2010
Anonymous
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Apr 12, 2009
Answers
2567
Questions
0
Helped
671471
Points
7153

1. Take the battery out of the laptop & try to turn on the laptop using power adapter only. If the computer turns on, then the battery is defective & needs to be replaced.
2. Make sure the power adapter is not defective. Test the output voltage of the power adapter using a voltmeter. Compare the voltmeter reading to the nominal value written on the adapter or the laptop.
3. If you have another processor which is compatible with your laptop's model, try swapping processors & test to see if the laptop will work.
4. The power button could be bad.
5. The motherboard could be defective & needs to be replaced.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Microwave vent won't work

may be short circuit at high voltage section replace diode or magnetron
0helpful
1answer

Unit switches off and displays error code 02-57

According to:

bassfisherman60

From the manual
02-57 Fan lock
This code is output when fan locking (over 30 seconds) is detected.
After the error message is displayed, the power turns off.

Perhaps opening the unit with the power unplugged (of course!) and clearing/cleaning the fan would help. It may be that the fan is just clogged with dust/debris.
1helpful
1answer

My ac unit wont start up. i have checked the

That could be many different things. If you would like working with me to get the answer then let me know. I will send a user manual and wiring diagram soon. I just want you to feel comfortable following through this with me, OK? Thanks, Sea Breeze
2helpful
1answer

Water won drain. stuckin last wash cycle and it

sounds like your pump is jammed,or faulty.remove water from unit by hand pull away from wall about 2ft tip unit back so u can look underneath. to the right hand front of the unit u will see a red or black fan on the pump, turn that fan clockwise and anticlockwise to unjam pump if it is jammed.fan should turn easily.please turn off power b4 u work on it, dont want any accidents. when u have done this put unit back level, turn power on select spin and start. please reply 4 more help
0helpful
1answer

Display says hi temperature, wont change when i adjust it. Tried turning it off/on and putting it on factory defaults. Also, air filter change light is on, and water wasn't coming out for a while until i...

Check underneath the refrigerator to see if the coils are clean. If they are covered with gunk, clean them.

Next, check the operation of the compressor (close to the coils mentioned above) and the compressor fan (also near the coils toward the rear of the refrigerator). Both of these must run for the unit to have the proper level of cooling. If the compressor fan is not turning, you will need to replace the fan motor.

Another possibility would be an inoperative evaporator fan inside the freezer unit. However, when this fails, the freezer often remains adequately cold at the top. The refrigerator part does not get cold enough.
0helpful
2answers

Trane XT300 thermostat reads HOLD-AC. Unit will

by simply turning power off to furnace or air handler may not work but there might be a reset button in the t-stat. remove the faceplate off of the t-stat it might be in their.
4helpful
2answers

Dvd turns off after displaying ''protection''

protection error message means that your unit's fan is not working

it is a feature to keep your unit from overheating

check if there is anything blocking the fan of your unit from rotation or replace the fan
0helpful
1answer

Outside unit come on for ac but inside won't come on for ac or heat

Turn Tsat to fan to see if inside unit will come on. If it does Tstat needs replaced. If not it is fan motor or fan relay. Possible cap. Do you here the fan relay come in. If it is a Good man unit it is time delay and you wont here it. Need to know your make of unit. Rusty
0helpful
1answer

Air conditioner motor

Your condenser fan costs less an $100 if you install it yourself. First with the system on and calling for cooling take a screw driver and spin the fan blade. If the fan comes on then it has a bad bearing, if it doesn't it's electrical. With power off remove the access panel and inspect the wiring etc.. Possible run capacitor.
0helpful
1answer

Hi fi wont turn on !

hi. im assuming its a technics / panasonic system judging by the F 61 error code? try testing the cooling fan at the rear (assuming it has one) i once had the same error code on my technics amp and it turned out to be a faulty cooling fan. after replacement out of a scrap unit, the amp worked perfect.
Not finding what you are looking for?

42 views

Ask a Question

Usually answered in minutes!

Top Toshiba Computers & Internet Experts

ExpressFiX
ExpressFiX

Level 2 Expert

691 Answers

k24674

Level 3 Expert

8093 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Toshiba Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides