Question about Leviton 104-05611-2WS 15A Decora Single Pole Illuminated Switch with Ground

1 Answer

I have the power source in the ceiling. I want to run wire to a single pole switch to a ceiling light?

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 518 Answers

Disconnect 1 side of light. Wire nut 1 wire from switch to 1 side of wire from light. Wire nut other side from switch to light. You now have a switch inline.

Posted on Sep 09, 2010

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Separate 1 switch 3 lights


You need separate wire going to each light.
Here are diagrams:
2 single pole switches, before you started to replace
http://waterheatertimer.org/images/2-single-pole-switches.jpg
Single pole and 3 pole to control each light separately: must identify black wire to each light. If each light does not have separate black wire inside the switch box, then it is not possible.
http://waterheatertimer.org/images/single-pole-and-3-pole.jpg
Add a comment

Jul 05, 2013 | Electrical Supplies

1 Answer

Electric switch install


Open following link for single-pole and 3-way installations:
http://waterheatertimer.org/How-to-wire-GE-15312-timer.html

If you have two hot wires inside the same box, that is unusual unless the power source is 240volt.
However it is possible that box has two hot wires and each controls a different light.

Jun 20, 2012 | Electric Electrical Supplies

1 Answer

I have a single pole switch that currently controls a bedroom outlet. i am installing a fan and light in the bedroom. i have a new triple switch that i want to control the existing outlet, the fan and the...


Wiring is not fully described: Location of hot wire and neutral wire from breaker box are unknown.
If Hot wire arrives in ceiling box first, the switch box will not have white neutral wires that are twisted together and covered with wire nut. Neutrals will be in ceiling box.

What is known: You are replacing single pole switch attached to one 14-2 wire going to light.
You are replacing light with a fan-light and replacing switch with a 3-pole TM8111 switch.
You have replaced 14-2 wire with 12-3 wire.

TM8111 wiring shows following link:
http://waterheatertimer.org/images/TM8111-switch-wiring-500.jpg
Fan pull-chain wiring shows following link:
http://waterheatertimer.org/images/Fan-motor-1-344.jpg
Assume neutrals in ceiling box.
Assume Hot wire in ceiling box: Connect 12-3 black wire to black Hot wire. Connect 12-3 white wire to black wire on light. Connect 12-3 red to red wire on fan.
White neutral from fan and white neutral form light connect to other white neutral wires and covered with wire nut.
Wiring at switch:
Black Hot wire from ceiling box connects to A COM terminal.
White wire to ceiling light connects to A SP2
Red wire to fan connects to A SP1

Jun 21, 2011 | Pass & Seymour Legrand TM8111 Three Single...

1 Answer

I turned power off to wire a ceiling fan, when I reset the breakers the Dimmer witched do not work.


Did you remove the dimmer switch or alter the wiring whilst putting the ceiling fan control in the wall? If so you have obviously wired it back up the incorrect way. How many original wires were at the light/dimmer switch. Will need to know colours etc?

Feb 13, 2011 | Lutron Ceana Single Pole 277V Switch,...

1 Answer

Hi i have a 9501ws c aspire single pole switch i am not sure about the connection of the whites do i run both blacks to the switch and tie the whites together this is a ceiling light thanks steve


Here is a site with a simple wiring diagram for a single light switch...

http://www.ask-the-electrician.com/Pics_Diagrams/singlepoleswitchdiagram1.JPG

Nov 28, 2010 | Cooper Wiring Devices "COOPER WIRING"...

1 Answer

Three way switch does not work properly


Very interesting problem! But easy to fix. It's not a defective switch, just a minor wiring error, which would be very hard to solve via back and forth text. So, instead of trying to figure out exactly which wires and terminals to swap at the new switch, it would be much easier to simply swap the light and fan wires at the ceiling fixture, I hope this is helpful. Good luck, Al Kupchella

May 16, 2010 | Pass & Seymour / Legrand 1595-2SWT...

1 Answer

How to do you wire 2 separate exhaust fans to a double single pole switch with a 20amp breaker problem


Your statement is a bit off the wall

Do you have two single pole switches or two double pole switches

You would normally provide a Live, Neutral and Earth to each fan via a switched , double pole, fused spur box .(You run a cable from the spur to a junction box) , you then run a LNE to each of the fans (using plastic trunking or conduit if the cables cannot be sunk into a wall).

Inside the junction box you remove the Live supply cable from the connector which should now be carrying three cables leaving the two cables running to the fans.

Put the Live wire into the spare connector inside the junction box

Get a twin and earth cable with the two wires marked up as Lives (Brown or Red in the UK, or whatever your wiring colour code dictates in your country) take those to a single pole switch which is convenient to you and wire them in

Back at the junction box put one of those wire into the connector where the two Supply wires for the fans are and tighten them up

Put the second wire from the On/Off switch to the Spare connector in the junction box which is holding the Live Supply

You then have a fused supply with a switch to break the circuit

If you do not need a switch then ignore the second part and just rely on using the switched fused spur to control them.

You can use a single pole switch but it is safer to stick with the double pole version

The breaker will be out of the loop as that will provide the power and you should not be fitting wires to it

Jan 02, 2010 | Broan-NuTone Nutone Utility Exhaust Fan...

1 Answer

Need to know wiring diagram for cooper single pole lighted switch


well lets see on one side you should have two brass screws that would be to interupt your lead to the fixture then you either have a brass and silver screws on the other side or you have black and white wires the black or brass is always hot the silver or white is neutral does that answer your question if not hit me back with a description of what your switch looks like

Jun 14, 2009 | Cooper Lighting Lighted Switch

1 Answer

Wiring to a 3 single pole combination switch


run 14-2 wire to power switches, then run one 14-3 wire and one 14-2 up to fixture..you will have an extra neutral but its okay... just tie all nuetrals together....this gives you the needed 3 hot wires!

Mar 03, 2009 | Pass & Seymour / Legrand 1595-2SWT...

Not finding what you are looking for?
Leviton 104-05611-2WS 15A Decora Single Pole Illuminated Switch with Ground Logo

Related Topics:

106 people viewed this question

Ask a Question

Usually answered in minutes!

Top Leviton Electrical Supplies Experts

 Kenneth
Kenneth

Level 2 Expert

50 Answers

Steve

Level 3 Expert

3287 Answers

Hippy_dd

Level 2 Expert

110 Answers

Are you a Leviton Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...