Question about Ingersoll Rand Stationary Air Cooled Rotary Screw Compressor 10 Hp, 35 Cfm At 125 Psi, Model# Ep

1 Answer

I have an Ingersol Rand SSR-EP40SE Rotary screw Air compresor. We ordered a new control panel for the unit because the old panel had a burnt resisitor. The new panel was installed and wont start the unit stating the rotation is incorrect. The old panel starts the unit. The rotation is correct. The unit is 460 Volts, Three phase unit. How can I let the new panel know the rotation is correct? The controller is an Intellisyi SSR 15, 100 Hp controller. Thank you in advance of any help you can give me regarding this matter.

Posted by on

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Novelist:

    An expert who has written 50 answers of more than 400 characters.

  • Expert
  • 205 Answers

First you need to program the controller. Controllers do not come programed for a specific compressor. You will need to enter factory set point and and set all parameters. Horse power, pressure, DOL start or wye delta start etc. The new controller is probably set incorrectly. Look at factory set points on the old controller and copy all the parameters and then set the new controller to those set points.

Posted on Nov 14, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Excessive oil with air


Replace the oil separator it should work or check the scavange line for blockage

Mar 28, 2014 | Ingersoll Rand Air Tools & Compressors

2 Answers

Ingersoll Rand SSR EP60 60hp Compressor w/ Intellisys 39817655 controller. Need to reset target pressure. What is the secret button sequence to access programming mode on this controller? I am aware of...


OK, Compressor should be shut down and showing (ready to start) in display. Press load/unload button once then press hidden right button within 3 seconds. This will let you access the set point program. It will include language, temperature and pressure, rated pressure,etc. Make sure you look at the data tag affixed to the unit and see what the rated pressure is for your unit. You can endanger yourself and equipment by over pressurizing the components of the compressor.

May 19, 2011 | Ingersoll Rand Stationary Air Cooled...

1 Answer

What does alarm start fault mean on the control panel on a ingersoll rand ssr ep-30 air compressor


I use to start up a 25 HP Ingersol screw type compressor. The only alarms I got were from power spikes which just needed the reset button to be pushed, then the on button - and the low oil sensor would shut it down and give an alarm when the tank was about half way down. They will blow up with no oil so there is a saftey margin on oil level.