Question about Jandy Lite 2 Natural Gas Pilot Light Heater

1 Answer

Fl4 code i replace the ignator but the code is still present i want to know if the conversion plug is the problem

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    President:

    An expert whose answer got voted for 500 times.

  • Jandy Master
  • 1,378 Answers

Thank you for posting your question here on Fixya.com.

If you follow the two wires up from the ignitor to the PCB what voltage do you get there? If it is 115V then it is unlikely the conversion plug is the problem. If you get 230 the plug is bad. If you get 0 look at the main PCB and/or the transformer. Be sure the inline fuses are OK as well.

If this answer does not fix your problem, please comment with additional details prior to rating the answer. Positive feedback is appreciated once your problem is solved!

John

Posted on Sep 05, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have the FL4 error code. Replaced igniter and checked the fuses. Still doesn't light


FL4 is related to the flow in your heater, you need to check first if you filters are too dirty, remove then reset breaker and try again if it go away it was your filter being too dirty, if it doesnt it is most likely the PressureSwitch on your heater.

Aug 17, 2015 | Jandy Laars Lite2 Pool & Spa Heater -...

1 Answer

Jandy Lite 2 LJ pool heater FL4 Fuse amp size


if blown they are 220 volt 3 amp you can also remove them

May 20, 2015 | Jandy Pool & Spa

1 Answer

Reset code 4


According to pages 34-38 of the installation and operations manual, FL4 is one of the codes that does not automatically reset itself after the fault is repaired. To reset the controller after an FL4 (or 6 or 7), press the "Select" button until the heater is off, wait a minute or two, and then press "Select" to put the heater into "Pool" or "Spa" mode. The heater should then go through the ignition sequence and function normally. NOTE: The manual also says that an FL4 code should be fixed by a professional.
http://www.zodiacpoolsystems.com/~/media/Zodiac/Global/Downloads/H/H0248900.ashx

Jun 20, 2014 | Jandy Lite2 LJ 400P, 400,000 BTU Heater,...

1 Answer

Code 1320 how to repair


code P1320 ignation signal circuit

it is a long test for this circuit and you will need a DVOM and a Scanner to run the test.

but basicly there are only 4 things that can set the code the ignation coils, the PCM, or the condensor, or the wiring betwine any of these componets, i recomend you take this one to a good shop, with out the test equipment it is only a guess as to what to replace, the most commmon thing would be the coils but it would be just a guess as to which one, it is not a sign of weakness to know when its time to get so help.

Dec 31, 2011 | 1999 Nissan Maxima

1 Answer

Jandy lite 2 heater model lj325n - code fl4 - hot surface igniter problem- I tapped the gas valve and checked the fuse , still getting the same code.


Igniter circuit is open. Check fuses on igniter wires. Identify and correct loose or broken wires.


Element has a fine crack in it. Replace


Igniter fault. Replace igniter.



Aug 31, 2011 | Jandy Lite 2 Natural Gas Pilot Light...

1 Answer

Ford windstar p0320 code


this code indacates that (2) successive erracit profile ignation pulses have occurred.possable causes are:

short circuit to ground in the secondery ignation circuit ( spark plug wires )

Aug 03, 2011 | 1995 Ford Windstar

1 Answer

P0320


this code indacates that (2) successive erracit profile ignation pulses have occurred.possable causes are:

short circuit to ground in the secondery ignation circuit ( spark plug wires )....god luck

Aug 03, 2011 | 1995 Ford Windstar

1 Answer

Fl 4 code


fl4 = Igniter Failure
A. Igniter circuit is open: Check fuses on igniter wires
B. Element has a fine crack in it: Replace igniter
C. Igniter fault: Replace igniter

Apr 09, 2011 | Jandy Lite 2 Natural Gas Pilot Light...

2 Answers

How do I fix a FL4 code


A FL-4 error is an ignitor failure. There are three things that need to be checked to correct the issue. First is the ignitor. Replace if broken or burnt or cracked. Second is the 220/120 vac conversion plug that is plugged into the main board in the burner compartment behind the box cover. The black transistor may be burnt. Replace if burnt. This will happen often if the heater is connected with 220 vac power source. I highly recommend connecting to a 120 vac source if possible. The heater seems to like it more. But remember when switching power supplies to follow all manufacturers instructions on doing so. If after replacing these two items the FL-4 problem still occurs, the control board in which the conversion plug plugs into also may need replacement. This should correct the fl4 error.

Jan 05, 2010 | Jandy Lite 2 Natural Gas Pilot Light...

1 Answer

Fl4 and fl3 fault


fl3 not rectification fl4 fault ignitions must replace ignitor kit and rectification kit from jandy need model # for parts

Jun 19, 2009 | Jandy Laars Lite2 Ld 400,000 Btu Heater

Not finding what you are looking for?
Jandy Lite 2 Natural Gas Pilot Light Heater Logo

400 people viewed this question

Ask a Question

Usually answered in minutes!

Top Jandy Pool & Spa Experts

David Spradling
David Spradling

Level 3 Expert

5922 Answers

Pj Kiley
Pj Kiley

Level 1 Expert

21 Answers

Bill Jordan

Level 2 Expert

372 Answers

Are you a Jandy Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...