I accidentally ran over the cord and then machine motor slowed down and stopped running. It wouldn't turn back on

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 10,319 Answers

Get a new cord. It was stretched and ripped apart under the outer rubber cords housing insulation

Posted on Sep 01, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Ran my rainbow e series without the separator. What should I do now?


If you were not vacuuming, just running it on blower setting you should be alright. The Separator prevents large items from getting into the vacuum when you are vacuuming. There is a gasket there that protects the motor from water. Double check where the separator goes and make sure there is no gunk or debris there, if so clean it out before running. Being that you were able to run it without any problems, noises or smells I would say you are probably fine.

GoodVac.com Technician
www.goodvac.com
1-800-775-6586

Jul 15, 2014 | Rainbow E series Canister Wet/Dry Vacuum

1 Answer

Eureka powerline umc-18 vacuum quit working


The Motor has locked up due to over heating. Once that happens the only way to go is either replace the motor drive or get a new cleaner. Do not try and keep energizing the Vacuum as you could blow circuit-breakers or start an electrical fire.

Dec 18, 2013 | Eureka 1810 Central System Vacuum

1 Answer

Won't turn on stop running in the middle of room.


Mine did the same thing. The electrical cord is loose where it plugs into the machine. When you pull the vacuum into the room it puts just enough strain on the cord to break the electrical connection. Push the plug on the cord firmly into the vacuum.

Sep 08, 2013 | Eureka 3276AZ Pet Lover Bagless Upright...

1 Answer

It ran fine then starting cutting out and then wouldn't turn on at all. No blockage in any of the hoses.


It sounds like you have a faulty switch or a bad power cord those would be the first place to start troubleshooting

Sep 05, 2011 | Vacuums

1 Answer

Brush not spinning


Remove the bottom plate to see if the belt came off of the motor shaft, or perhaps it broke in two when the brush stopped turning. Hope this helps!

Jun 28, 2010 | Dyson DC14 Animal Bagless Upright Cyclonic...

1 Answer

Sebo Automatic X1 Stopped. Yesterday my Sebo stopped working. I know this can happen if it gets blocked and overheated so I checked for blockages, none. And left it too cool down. Tried it again but it was...


Hello,

Ok, thanks for the clarification. Even though the cord doesn't have any external damage, it's still very possible that it has gone bad. When a Sebo upright doesn't even start, this can mean one of several things. The parts that could go bad that would cause the machine not to turn on would be the cord (most common on a Sebo), the on/off switch, the PC board that's on top of the motor, or the actual motor. In the 7 years that I've been selling Sebo, I have only changed out one PC board, and I've never had to replace a single motor on a Sebo yet. I have had to replace several cords over the years, some showing external damage, others didn't show any damage.

The cord and the switch are going to be the easiest parts to test, and also happen to be the most common, so this is a great place to start.


Here's how you can test the switch and the cord on the vacuum cleaner. You'll need to have a simply Electrical tester that will test if current is going through the cord. Here's a link to a similar one that is very inexpensive that I used in this repair solution:
http://www.homedepot.com/h_d1/N-5yc1vZ1xh7/R-100183054/h_d2/ProductDisplay?langId=-1&storeId=10051&catalogId=10053


Step 1. Unwrap the electrical cord from the vacuum cleaner, and set the entire cord aside. Also remove the on-board wand that rests directly behind the bag housing. After the wand has been taken out, you should see on the left side of the vacuum where the handle goes into the body of the vacuum a little gray lever (my picture this lever is yellow as I only had a Sebo X5 on the floor, but the repair is identical). This is what the lever looks like:


80f63f9.jpg
Step 2. As you'll see if you look closely, the lever says "closed". Turn the lever towards the front of the vacuum so the lever reads "open".


8d9a86b.jpg
Step 3. Once the lever is moved to open, lift straight up on the entire handle assembly to remove it from the vacuum cleaner.


3c3c9cb.jpg
Step 4. Once you have the handle assembly out of the vacuum cleaner, turn the handle upside down. You'll be able to see two small metal electrical terminals that connect into the base of the vacuum where the handle meets the vacuum cleaner. Make sure that both terminals are visible. I have seen a few Sebo's where the handle has come loose, and these terminals no longer make connection to the rest of the vacuum, causing the vacuum not to turn on. You can re-attach the handle into the vacuum cleaner, turn the lever on the side from open back to closed, and test the vacuum to see if it comes on.

Step 5. If the vacuum failed to come on after reinstalling the handle, take the handle back out of the vacuum. Put one of the wires from your electrical tester into each terminal in the bottom of the handle assembly. Make sure that the tester is actually making contact with the metal terminals. It should look like this:


614747f.jpg
Step 6. With each of the electrical tester wires pushed down into the handle and making sure they are making contact, plug the cord into a standard wall outlet. If current is present, the electrical tester will light up. If not light comes on, try flipping the on/off switch and see if this has an effect on if the tester lights up or not:


1fdc3c7.jpg
As you can see in the picture above, the cord and switch on this vacuum are good. If your tester lights up when you put it into the handle, then this means that your cord and switch are good. This means that either your motor, or PC board have gone bad.

If the tester signals that you don't have any power at the bottom of the handle, then this means that either your switch or your cord is bad.

If you will please let me know the results of the electrical test here on the bottom of the handle, I will then go into the next steps of the repair, and explain how to open up the machine and either replace the cord / switch, or if you did have power here, the pc board or the motor.

Please just use the clarification request form that you used last time. I hope this was helpful in diagnosing your machine. If this helped you, please be kind and rate the repair as helpful by clicking the thumbs up icons in the top of the repair.

I look forward to helping you fix your Sebo.

Chris J.
GoVacuum

Apr 06, 2010 | Sebo Automatic X1 Bagged Upright Vacuum

1 Answer

My bissell ran over the cord and stopped sucking


The belt probably broke or stretched and that is why it stopped working. Here is the belt you need:

Bissell Lift Off Belts

Feb 07, 2010 | Bissell 3750 Lift Off Bagless Upright...

1 Answer

Dyson Animal 17 - brush stopped turning


The belt will stop itself from spinning if you accidentally picked up a shoestring or vacuumed the edged of a carpet and the carpet got caught. To have the brush spinning again, simply step on the front of the machine, pull back the handle, turn the machine on with the red power button and press the gray button next to the red button - that's the ON/OFF button for the brushbar. If it doesn't spin, press and hold the button down for 10 seconds. If it still doesn't work, call the Dyson helpline, they'll have you open up the cleaner and inspect the belt and brushbar motor and if all else fails, they'll refer you to a local repair dealer in your area to fix it.

Jun 24, 2009 | Dyson DC17 Animal Bagless Upright Cyclonic...

1 Answer

Ran over cord and the vacuum shut down, won't


sounds like it might have broken a wire in the cord and may have to replace the cord unless you can find the broken wire and splice it back together

Apr 23, 2009 | Kirby Generation 3 Bagged Upright Vacuum

1 Answer

MY HOOVER Steamvac F5906-900 does not run


There is a switch, but could be a bad cord, or the motor went bad.

Jan 06, 2008 | Hoover F5906-900 Upright Steam Vacuum

Not finding what you are looking for?
Kirby G4 Bagged Upright Vacuum Logo

Related Topics:

35 people viewed this question

Ask a Question

Usually answered in minutes!

Top Kirby Vacuums Experts

Les Dickinson
Les Dickinson

Level 3 Expert

18402 Answers

JoeVacs

Level 2 Expert

357 Answers

Donald DCruz
Donald DCruz

Level 3 Expert

17130 Answers

Are you a Kirby Vacuum Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...