Question about Amcor PLM-14000E Portable Air Conditioner

1 Answer

I have an AMCOR 1400E and my compressor kicks on and gets very hot but no cold are comes out of the unit, I think i may have a bad compressor and don?t know who to call about the warranty since amcor is no longer in business?

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Expert
  • 382 Answers

Dear sir

if your aircon compressor is working and it,s not getting cold then it can be cause of leakage in aircon system then need to refill freon on your system .
please contact to your area amcor dealer for get the benefit of your warranty period(if it is in under warranty)

thank you
hope answer the question

Posted on Sep 25, 2010

  • mastamps Jun 08, 2011

    there are no area amcor dealers, they closed down and screwd everyone who purchased from them, most of these units that come on and off with the compressor are new out of the box and there doesn't seem to even be anyone local that wasnts to fix it even if we pay, it is just a 100lb weight now

×

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

KF9000e. Why does compressor cycle at short intervals?


Yes. due to low rpm of fan motor in the condensor copil. or dirty condensor coil. I If so, replace fan capacitor.
If all good, check the seating of condensor set. It needs minimum 2mtrs open space for air throw. If not due to overheat compressor gets short cycling on and off.

Sep 07, 2015 | Amcor Heating & Cooling

1 Answer

I have an AMCOR ALTL1200E, fan works, cold air comes out when the compressor turns on BUT after 5 minutes compresor turns OFF, then after 5 minutes again it turns on, what is wrong, thanks


Sounds like the unit is cycling off on a high head pressure (condenser coil too hot). When the condenser cools, the automatic switch resets. The unit cuts off again when the condenser heats up again. Clean the condenser coil, and clear out any debris (bird's nest, lint etc.)

Aug 30, 2013 | Amcor ALTL-12000E Portable Air Conditioner

1 Answer

Compressor runs and gets hot but fan will not kick on. Replaced the capacitor and that did not help. One side of coils gets hot, the other side gets cold, which seems normal. Just can't get the fan...


Don't run the compressor for any length of time without the fan operating. Is it possible that the fan must be replaced? Can you power the fan safely to test it?
Gary

Jul 26, 2011 | Maytag M7DH45B2A Dehumidifier

1 Answer

The unit will not produce cold air. It only pushes out room temp air. Altough I am not an expert, I think it is the compressor, or the tempature control unit (thermostat?) The unit does seem to make an...


I have a Amcor AF 1200E air conditioner, it only blows warm air and it is real dirty on inside filters, we took out 3 filters but there is still dirt on filters behind these, do we take it apart to clean, I would like a manual , do youknow where I can download one at? thanks

Sep 06, 2010 | Amcor AF9000E Portable Air Conditioner

1 Answer

Loud screeching sound coming from the unit


It sounds like the fan motor needs lubricating. Do you need help with this?

May 05, 2009 | Amcor A12000E Nanomax Portable Air...

1 Answer

Cooling problem


Since it is not so hot outside you may have to adjust the Thermostat to a lower setting to get the AC unit to kick on the compressor and blow out cold air. Give it a try, and if not the T-stat then we can go from there.

Jul 14, 2008 | Office Equipment & Supplies

1 Answer

Beverage Air ST58N Not cooling


Compressor is cycling on the overload protector. Cause could be a bad starting relay but is more than likely the compressor is bad.

Jun 11, 2008 | Carrier ST58N

2 Answers

Unit Cools for two minutes and takes a three minute break.


There is a safety shutting down the compressor. Either the thermal overload is cutting it off because its getting too hot for some reason. Dirty coil, filter or fan speed, though you said the fan is running so that's out. Does the compressor feel really hot when its cycling on and off? If its not, its possible the thermal disc is bad, but unlikely. The other safety is low pressure (freon) You kind of need a set of A/C gauges to test this accurately. Hope this helps. These safeties are there to prevent the compressor from burning out, when something small is the problem, as its the most expensive part. You sound like have covered all the bases, so check the coils and filter, if there still is a problem, then you need to call a service tech. for warranty.

Mar 07, 2008 | Amcor PLM-14000E Portable Air Conditioner

Not finding what you are looking for?
Amcor PLM-14000E Portable Air Conditioner Logo

Related Topics:

204 people viewed this question

Ask a Question

Usually answered in minutes!

Top Amcor Heating & Cooling Experts

AJMAL KHAN

Level 2 Expert

382 Answers

Donni Steen

Level 3 Expert

659 Answers

Michael Youngman
Michael Youngman

Level 2 Expert

156 Answers

Are you an Amcor Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...